Product Description
The state-of-the-art Lab Freeze Dryer YR05197-1 is engineered for optimal performance in cryogenic processing and preservation. This advanced model can accommodate 24 ampules, making it ideal for laboratories requiring high-volume processing. The cold trap temperature reaches an impressive ≤-60℃, with an optional extension to ≤-80℃, allowing for versatility in handling sensitive samples.
This freeze dryer boasts a cold trap with a diameter of Ф270mm and a depth of 400mm, providing a noteworthy ice collecting capacity of 6 kg every 24 hours. The unit is powered by a robust 1400W motor, ensuring efficient operation. The device has an ultimate vacuum speed of ≤5 pa, guaranteeing thorough freeze drying. Its compact design, with main unit dimensions of 630×580×970mm, makes it suitable for a variety of laboratory spaces, while the optional -80℃ variant measures at 810×580×950mm.
| Model | YR05197-1 |
| Ampule numbers | 24pcs |
| Cold trap temp. | ≤-60℃,optional≤-80℃ |
| Cold trap depth | 400mm |
| Cold trap dia | Ф270mm |
| Ice collecting capacity | 6kg/24h |
| Pumping speed | 4L/S |
| Ultimate speed | ≤5pa |
| Power | 1400w |
| Main unit weight | 105kg |
| Main unit dimension | 630×580×970mm |
| -80℃ main unit dimensions | 810×580×950mm |
| T frame sizes | 430×480mm(H *L) |
| Flask frame sizes | 610×600mm(H *L) |
| Cooling mode | wind cooled |
| Defrosting mode | by air |
Market Price
In the marketplace, lab freeze dryers similar to the YR05197-1 model, which exhibits high-end specifications, typically range from approximately $7500 to $8500. This pricing bracket reflects the freeze dryer’s advanced capabilities and durability. Investing in such equipment ensures reliable performance and precision in laboratory settings. You can inquire about specific pricing and avail exciting offers by requesting a quote directly at Kalstein’s platform.
Frequently Asked Questions
What is the main function of a lab freeze dryer?
A lab freeze dryer preserves materials by removing moisture through sublimation, which extends the shelf life without compromising the sample integrity.
Can this freeze dryer handle sensitive biological samples?
Yes, the YR05197-1 is equipped to handle a variety of biological samples due to its low temperature capabilities and gentle sublimation process.
How often should the freeze dryer undergo maintenance?
Routine checks and maintenance should be performed every six months to ensure optimal performance and longevity of the unit.
Is there a technical support team available?
Kalstein offers excellent customer support and technical assistance for troubleshooting and maintaining the freeze dryer.
Advantages and Disadvantages
The YR05197-1 freeze dryer excels in offering precise temperature control and high volume capacity, which are crucial for laboratory freeze drying. Its robust power and advanced features provide reliable and efficient operations. However, the complexity of handling such advanced technology could necessitate training for optimal use, which may be considered a disadvantage for users who are new to such equipment.
Another significant advantage is its flexible temperature range, allowing for the processing of delicate samples. Conversely, its weight and size, while compact, might pose a challenge for smaller spaces. Despite these considerations, this freeze dryer remains a valuable asset for scientific research and laboratory work.
Product Use in the Field
In practical applications, the Lab Freeze Dryer YR05197-1 is indispensable in pharmaceuticals, biotechnology, and research laboratories. It is utilized for the preservation of biological samples, enzymes, and vaccines. Its precise control over sublimation ensures that sensitive compounds retain their structural integrity and activity.
Researchers benefit from its ability to handle multiple samples simultaneously, significantly reducing processing times and improving laboratory workflow. The innovation behind the YR05197-1 aids in supporting advanced research endeavors and production requirements in various scientific fields.
Recommendations
To maximize the benefits of the YR05197-1 freeze dryer, it is advisable to conduct regular maintenance and calibrations. Proper training for operating this technology will enhance performance and results. Users should ensure that their laboratory facilities are equipped to handle the environmental requirements for optimal freeze dryer operation.
Investing in temperature monitoring systems and spare parts can preemptively mitigate potential downtimes. Explore the possibility of upgrading to the -80℃ variant if your work involves highly sensitive materials that benefit from lower temperatures. To explore more about this equipment and receive tailored advice, engaging with Kalstein’s customer support can provide valuable insights.
Si está buscando una fusión de innovación y calidad, has llegado al lugar correcto. En Kalstein te ofrecemos el lujo de explorar nuestro exclusivo catálogo de equipos de laboratorio. Fabricamos cada equipo con un nivel de excelencia. Nuestros canales de compra online, intuitivos y ágiles, están diseñados para su comodidad, asegurando los precios más amigables. No dude más, le damos vida a la ciencia, es hora de hacer parte de nuestra comunidad. https://kalstein.net/en/product/t-type-lab-freeze-dryer-yr05197-1/.