Product Description
The YR05316 Biomedical Chest Freezer stands out in the realm of laboratory equipment with its state-of-the-art features tailored to meet rigorous scientific demands. With a substantial capacity of 105 liters, it presents a versatile storage solution for biomedical applications that require precise temperature control. The unit’s temperature range spans from -10°C to -25°C, ensuring optimal conditions for storing sensitive materials. Designed to operate efficiently within ambient temperatures of +10°C to +32°C, this freezer is adaptable to a broad range of environments.
Equipped with a microprocessor controller and a digital display, the YR05316 offers accurate temperature readings and easy management, thus minimizing room for error. Its refrigeration system is robust, prominently featuring a DONPER compressor and utilizing R290 as the refrigerant, which is known for its lower environmental impact. The direct cooling mechanism and manual defrost ensure consistent performance. Power efficiency is another hallmark of this freezer, with a rated power of 174 watts and power consumption of merely 1.59 kWh per day.
| Model | YR05316 |
| Performance | |
| Temperature Range | -10~-25°C |
| Ambient Temperature | +10~+32°C |
| Controller | Microprocessor |
| Display | Digital Display |
| Refrigeration System | |
| Compressor/Brand | 1/ |
| DONPER | |
| Refrigerant | R290 |
| Cooling Type | Direct cooling |
| Defrost Type | Manual |
| Electrical Data | |
| Power Supply(V/Hz) | 220~240V/50~60;115/60 |
| Rated Power(W) | 174 |
| Electrical Current(A) | 1.48 |
| Power Consumption | 1.59 kWh/24h |
| Dimensions | |
| Capacity | 105L |
| Interior Size(W*D*H) | 480*380*665mm |
| Exterior Size(W*D*H) | 615*570*880mm |
| Package Size(W*D*H) | 675*625*1000mm |
| N.t./G.t.(approx) | 41.8/54kg |
| Loading Qty(20’/40’/40’H) | 27/57/57 |
| Alarm | |
| High/Low Temperature | Y |
| Sensor Error | Y |
| Power Failure | Y |
| Accessories | |
| Caster | 4 |
| Remote alarm port | / |
| Test hole | 1/25MM |
Market Price
The YR05316 Biomedical Chest Freezer offers a cost-effective option for laboratories, with its price positioned competitively in the range of $900 to $1760 USD. This pricing point reflects the superior quality and advanced features of the freezer, making it an attractive acquisition for institutions looking to balance budget constraints with technological expertise.
Frequently Asked Questions
What type of cooling system does the YR05316 freezer use?
The YR05316 employs a direct cooling system, ensuring efficient and consistent temperature maintenance essential for biomedical storage.
Is there an alarm system integrated into the freezer?
Yes, the freezer includes alarms for high/low temperature, sensor errors, and power failures, enhancing reliability and user confidence.
What is the energy consumption of this freezer?
The unit is energy-efficient, consuming only 1.59 kWh/24h, making it a sustainable choice for long-term use.
Advantages and Disadvantages
Advantages
- High capacity and adaptable temperature range make it ideal for diverse storage needs.
- Equipped with essential alarms and digital display for precision control and monitoring.
- Environmentally friendly refrigerant R290.
Disadvantages
- Manual defrosting required, which may increase maintenance efforts.
- Limited to regions with compatible power supplies (220~240V).
Field Use
The YR05316 Biomedical Chest Freezer is an indispensable asset in many laboratory settings, where preserving biological samples, chemicals, enzymes, and reagents at precise temperatures is vital. In medical and research facilities, the freezer supports advances in cellular and molecular biology by safeguarding the integrity of the samples. Its ample volume allows for bulk storage without sacrificing temperature uniformity, essential for experimental repeatability.
The freezer is also instrumental in clinical settings, storing vaccines and pharmaceuticals that must remain stable within strict temperature guidelines. This adaptability and reliability make it a favorite across multiple scientific disciplines.
Recommendations
To optimize the performance and longevity of the YR05316 Biomedical Chest Freezer, regular maintenance such as manual defrosting is essential. Position the freezer in a location that maintains ambient temperature conditions within its operational range and ensures adequate ventilation to enhance cooling efficiency. Additionally, periodic checks of the alarm functions and digital controller help prevent potential malfunctions. For seamless procurement and pricing inquiries, engage with our online Kalstein Plus platform for automatic quotes suited to your needs.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalogue of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/105l-biomedical-chest-freezer-open-top-yr05316/.