Product Description
The COD Analyzer YR06295 stands as a cutting-edge solution in the realm of spectrophotometry, designed for fast and accurate measurement of chemical oxygen demand (COD) in various water samples. This advanced instrument leverages fast digestion spectrophotometry to deliver precise results, supporting a wide measurement range of 10-10000 mg/L. With an impressive accuracy of <5% and a resolution of 0.01, it ensures reliability in data analytics crucial for water quality assessment.
One of the standout features of the YR06295 model is its imported Silicon Photodiode serving as the light source, ensuring superior performance and longevity. The device hosts a 7-inch high-resolution 1024 x 600 touch screen display, providing a user-friendly interface that simplifies data interpretation. Additionally, its USB output allows for seamless data transfer, facilitating detailed record-keeping and analysis.
| Model | YR06295 |
| Measurement Method | Fast digestion spectrophotometry |
| Measuring Range | 10-10000 mg/L |
| Accuracy | <5% |
| Resolution | 0.01 |
| Light Source | Imported Silicon Photodiode |
| Display | 7-inch high-resolution 1024 x 600 touch screen |
| Output | USB (for data transfer) |
| Power | AC 220V/50Hz or AC 110V/60Hz |
| Ambient Temperature | (5-40) °C |
| Ambient Humidity | Relative humidity ≤ 85% (No condensation) |
Market Price
In the competitive landscape of spectrophotometry equipment, the COD Analyzer YR06295 is positioned as both a premium and cost-effective option. The market price typically ranges between 1400 USD to 2200 USD, reflecting its advanced features and precision engineering. This pricing makes it accessible to laboratories and industries prioritizing quality without compromising on budget considerations. For the precise price and to tailor it to your specific needs, we encourage potential buyers to request a quotation, or to generate an automatic quotation through the Kalstein Plus platform.
Frequently Asked Questions
How accurate is the COD Analyzer YR06295?
The analyzer boasts an accuracy level of <5%, ensuring reliable and consistent results with each use.
What is the measurement range of this device?
The device features a broad measurement range of 10 to 10000 mg/L, suitable for various water quality applications.
Is the device user-friendly?
Yes, it features a 7-inch high-resolution touch screen that enhances its usability, ensuring users can easily operate and navigate through its functionalities.
Advantages and Disadvantages
Advantages: The YR06295 stands out with its fast digestion spectrophotometry, facilitating quick and accurate measurements critical for high-paced laboratory environments. Its wide measuring range and superior light source technology make it adaptable and reliable for various applications. Additionally, the inclusion of a USB port for data transfer underlines its modern approach to data management.
Disadvantages: While the device is highly advanced, it requires careful handling and understanding of spectrophotometry to maximize its capabilities. Initial users may need some training to familiarize themselves with its operations.
Use of the Product in the Field
The COD Analyzer YR06295 is deployed extensively in environmental monitoring and water treatment facilities. Its precision and wide measurement range allow for effective detection of organic pollutants in water, enabling industries to maintain compliance with environmental regulations. From municipal water treatment plants to industrial effluent monitoring, this device supports informed decision-making through accurate data.
Field applications also extend to research institutions where rapid and accurate data analysis is essential. By facilitating prompt results, the YR06295 equips researchers with data critical for ecological studies and assessments.
Recommendations
To ensure the longevity and optimal performance of the COD Analyzer YR06295, regular maintenance and calibration are recommended. Users should adhere to the operational guidelines provided, ensuring the device is kept within its specified ambient conditions of 5-40 °C and relative humidity of ≤ 85% without condensation. It is also advisable to periodically verify the accuracy of the equipment against known standards.
When transporting the device, ensure it is securely packed to avoid any damage to its sensitive components. Utilizing the Kalstein Plus platform, users can conveniently keep track of maintenance schedules and access support materials.
If you are seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate any longer; we bring science to life, and it’s time for you to be part of our community. https://kalstein.net/en/product/cod-analyzer-yr06295/