Product Description
In the realm of medical innovation, the YR02176 patient monitor stands out thanks to its state-of-the-art capabilities. Designed to offer comprehensive and accurate patient monitoring, this device integrates an extensive array of features. From ECG monitoring with both 3-lead and 5-lead modes to the assessment of heart rate, respiration, and more, it ensures meticulous health tracking whether in surgical settings or regular check-ups.
The ECG module supports both 5-lead (RA, LA, LL, RL, V) and 3-lead (RA, LA, LL) configurations, providing diverse connection methods. It delivers a waveform of 1ch and offers gain settings of x250, x500, x1000, and x2000, accommodating different monitoring needs. The heart rate range spans from 15 to 300 bpm for adults and slightly wider from 15 to 350 bpm for neonatal and pediatric patients, all with a remarkable accuracy of ±1% or ±1 bpm. Additionally, it includes ST segment monitoring, with a range of -2.0 to +2.0 mV and an accuracy of -0.8 to +0.8 mV.
| Model | YR02176 | |
| ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) |
| Connection method | I, II, III,AVR,AVL,AVF,V | |
| Lead Mode | 3 Leads (RA,LA,LL) | |
| Connection method | I, II,III | |
| Waveform | 1ch | |
| Gain | x250, x500, x1000, x2000 | |
| HR Range | Adult: 15~300bpm | |
| Neo/Ped | 15~350bpm | |
| Accuracy | ±1% or ±1bpm | |
| Resolution | 1bpm | |
| Sensitivity | >200(uVp-p) | |
| Differential input impedance | ≥5MΩ | |
| ST segment Monitoring Range | ||
| Measure Range | -2.0~+2.0mV | |
| Measure Accuracy | -0.8mV~+0.8mV | |
| Heart Rate | Measuring range | 20~300bpm |
| Accuracy | ±1bpm | |
| Resolution | 1bpm | |
| Sensitivity | >200UVp-p | |
| Respiration | Method | Impedance between R-F(RA-LL) |
| Differential Input Impedance | >2.5MΩ | |
| Measuring Impedance Range | 0.3~3.0 MΩ | |
| Base line Impedance Range | 200~4000Ω | |
| Bandwidth | 0.1~2.5Hz | |
| Respiration Rate | Adult: 2~120BrPM | |
| Neo/Ped | 0~150BrPM | |
| Resolution | 1 BrPM | |
| Accuracy | ±2 BrPM | |
| Alarm | 10~40S | |
| NIBP | Method | Oscillometric |
| Mode | Manual/Auto/STAT | |
| Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
| Measuring Period in STAT Mode | 5 Min | |
| Pulse Rate Range | 40~240bpm | |
| Alarm Type | SYS, DIA, MEAN | |
| Resolution | ||
| Pressure | 1mmHg | |
| Accuracy | Maximum Mean error: 5mmHg | |
| Maximum Standard deviation | 8mmHg | |
| SPO2 | Display | Number of SPO2,waveform of capacity,Pulse |
| Measuring range | 0~100% | |
| Resolution | 1% | |
| Accuracy | 70~100% (±2%) | |
| Alarm system | Audio-video alarm | |
| Pulse rate range | 0~300bpm | |
| TEMP | Channel | 2 |
| Measuring and Alarm Range | 0~50ºC | |
| Resolution | 0.1ºC | |
| Accuracy | 0.1ºC | |
| Actualization interval | about 1 Second. | |
| Average Time Constant | <10 Second. | |
Market Price
The YR02176 patient monitor is an advanced piece of technology in the medical equipment sector, offering a range of high-end features at a competitive price. On average, this device is available in the market for a price range starting from approximately $4500 up to $5000. This range reflects similar models which provide multifaceted monitoring capabilities, thus making this device a valuable investment for medical facilities seeking cutting-edge technology.
Frequently Asked Questions
What is the accuracy of the YR02176 in ECG monitoring?
The YR02176 offers an impressive accuracy in ECG monitoring with an accuracy of ±1% or ±1 bpm, ensuring reliable diagnostic support for healthcare professionals.
Can the YR02176 monitor pediatric cases?
Yes, the YR02176 is well-equipped to monitor neonatal and pediatric patients, with a heart rate range of 15 to 350 bpm designed for these cases.
What kind of alarms does the YR02176 have?
The YR02176 is integrated with audio-video alarm systems, crucial for notifying healthcare providers of any abnormal patient conditions promptly.
Advantages and Disadvantages
Advantages: The YR02176 patient monitor stands out for its comprehensive ECG capabilities and wide range of health parameter monitoring. Its precision in measurement and detailed display options provides confidence to medical professionals by ensuring patient safety and reliable diagnostics. The high-resolution display and sensitivity further bolster its functionality.
Disadvantages: While the YR02176 offers numerous advanced features, its complexity might require trained personnel for optimal use. Additionally, its premium price point, while justified by its capabilities, may pose a barrier for smaller medical establishments.
Product Use in the Field
The practical application of the YR02176 in clinical settings is extensive. It plays a vital role in intensive care units, enabling constant patient monitoring that supports physicians in making informed decisions about patient health management. Equipped to provide precise readings, this monitor is indispensable in operating rooms, ensuring vital signs are continually observed during surgeries. Moreover, in emergency settings, its quick response time and alarm systems facilitate timely interventions.
Recommendations
To fully leverage the YR02176’s potential, it is recommended that user training be conducted to ensure effective device operation and maximize its monitoring capabilities. Regular maintenance and calibration checks are advised to uphold accuracy and prolong device lifespan. Engaging with support services for periodic software updates will also enhance device utility and ensure it remains at the technological forefront.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalogue of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most user-friendly prices. Do not hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/patient-monitors-yr02176/.