Advanced Electrosurgical Generator YR02147: Technical Insights and Applications for Precision

Product Description

The Electrosurgical Generator YR02147 is engineered to deliver efficient and precise surgical performance through its advanced functionality. This model supports multiple working modes, including Monopolar and Bipolar options, providing versatility and efficiency for surgical procedures. The device offers a powerful Monopolar Cut capability, with a Pure cut delivering a maximum power of 60W at a rated load of 500Ω. Additionally, it provides a Blend 1 option with 50W at 500Ω, catering to various surgical needs.

The Monopolar Coagulation is optimized at 50W /500Ω, ensuring reliable coagulation performance. For Bipolar operations, the YR02147 offers cut and coag capabilities both at 40W / 100Ω, delivering consistent and controlled energy for procedures requiring precise surgical intervention.

The generator meets electrical requirements efficiently, with a Monopolar Measuring Frequency set at 4.0MHz ±2% and a Bipolar Measuring Frequency at 1.84MHz ±2%. Additionally, the device is designed to handle a Max Input Current of 1400 VA, making it highly suitable for rigorous surgical environments.

With a design ready for diverse environmental conditions, this electrosurgical unit can operate effectively across temperatures ranging from 50°C to 40°C, in humidity levels ≤ 95% non-condensing, and at pressures from 700 hPa to 1060 hPa.

Model YR02147
Working Mode Max Power / Rated Load
Monopolar Cut Pure cut 60W / 500Ω
Blend 1 50W / 500Ω
Monopolar Coag Standard Coag 50W /500Ω
Bipolar Cut Bipolar Cut 40W / 100Ω
Bipolar Coag Bipolar Coag 40W / 100Ω
Electrical requirement Monopolar Measuring Frequency 4.0MHZ ±2%
Bipolar Measuring Frequency 1.84MHZ ±2%
Max Input Currency 1400VA
Environmental Conditions for Use Condition Range
Temperature 50°C to 40°C
Relative humidity ≤ 95% non-condensing
Pressure 700 hPa to 1060 hPa

Market Price

Understanding the market price of the Electrosurgical Generator YR02147 is crucial for both budgeting and ensuring value. Currently, similar devices in the market range from 3900 USD to 4700 USD, providing a balance between quality and affordability. Investing in this equipment ensures access to the latest in surgical technology, enhancing procedural outcomes and operational efficiency.

Frequently Asked Questions

What are the main features of the YR02147 Electrosurgical Generator?

The YR02147 model stands out for its dual Monopolar and Bipolar operational modes, offering high power outputs across these modes. It includes optimized measuring frequencies and maximum input capacity, catering to varied surgical environments and requirements.

Is the YR02147 model suitable for all types of surgeries?

While the YR02147 is engineered to handle a wide range of surgical procedures due to its versatile modes, it is best to consult with a medical equipment specialist to ensure it aligns with specific surgical needs and applications.

How can I ensure optimal performance from my electrosurgical generator?

Regular maintenance, adhering to recommended environmental conditions, and utilizing the device’s modes appropriately will enhance performance. Detailed user manuals and professional consultations are also advised.

Advantages and Disadvantages

The Electrosurgical Generator YR02147 offers a suite of advantages, including its dual operation capabilities and precision in power output, which translates to flexibility and efficiency in surgical procedures. The easy-to-use interface and durable build are additional benefits, providing long-term reliability.

However, potential disadvantages include the complexity of mastering its full range of features without adequate training, as well as the necessity to ensure compatible surgical environments to leverage its advanced technological capabilities fully.

Usage in the Field

In practical settings, the YR02147 Electrosurgical Generator is deployed across various surgical disciplines, from general surgery to specialized procedures. The device’s ability to offer precise control over cutting and coagulation makes it a valuable tool in operating rooms. Surgeons benefit from its adaptability to different tissue types and procedures, which is facilitated by the robust performance metrics it delivers consistently.

Field usage has shown significant reductions in surgical time and enhanced patient outcomes, reaffirming the device’s role as an essential component in modern surgical setups. With appropriate training, medical teams can leverage its features to perform complex surgeries with higher precision and reduced risk of complications.

Recommendations

For optimal usage, it’s recommended to ensure that operators of the YR02147 Electrosurgical Generator undergo comprehensive training. Regular equipment maintenance, routine inspections for compliance with safety standards, and utilizing manufacturer resources for technical support will vastly improve operational efficiency and device longevity.

Beyond the technical aspects, engaging with peer networks and professionals can provide insights into best practices and emerging trends that might influence future applications of your device. Always be proactive about firmware updates and software improvements that Kalstein may release, ensuring you stay at the cutting edge of surgical technology.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it is time to be part of our community. https://kalstein.net/en/product/electrosurgical-generators-yr02147/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]