Benchtop Spectrophotometer YR05476: A Comprehensive Guide to Its Features and Applications

Description of the Product

The Benchtop Spectrophotometer YR05476 sets a new standard in color analysis and transmission accuracy for laboratory applications. Designed specifically for industries such as paints, inks, textiles, garments, and printing, this device ensures precise color transfer and quality control. Its innovative design integrates a range of features that enhance its measurement capabilities, making it an indispensable tool for professionals seeking reliability and precision.

One of the standout features of the YR05476 is its optical geometry. It supports reflectance measurements with diffused illumination at an 8-degree viewing angle, and it includes both specular component included (SCI) and specular component excluded (SCE) modes. Transmittance measurements operate with diffused illumination at a 0-degree viewing angle, again supporting SCI and SCE modes. The device conforms to several standards, including CIE No.15, GB/T 3978, and ISO7724/1, ensuring compliance with international measurement criteria. Furthermore, the instrument’s integrating sphere measures 154mm in diameter, providing ample space for diverse sample sizes.

Model YR05476
Optical Geometry Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Application It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size Φ154mm
Light Source 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360-780nm
Wavelength Interval 10nm
Semiband Width 10nm
Measured Reflectance Range 0-200%
Measuring Aperture Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component Reflectance: SCI&SCE / Transmittance: SCI&SCE
Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle 2°/10°
Illuminant D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed Data Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time About 2.4s (Measure SCI & SCE about 5s)
Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.12
(Average for 12 BCRA Series II color tiles)
Dimension L*W*H=370x300x200mm
Weight Approx. 9.6kg
Power AC 24V, 3A Power adapter power supply
Illuminant Life Span 5 years, more than 3 million times measurements
Display 7-inch TFT color LCD, Capacitive Touch Screen
Data Port USB & Bluetooth & Print serial port
Data Storage Standard 5000 Pcs, Sample 40000 Pcs
Language Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish)
Operating Environment 0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment -20~50℃, 0~85%RH (no condensing)
Standard Accessory Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component
Optional Accessory Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Market Price

When considering the acquisition of a high-quality spectrophotometer, understanding the market pricing can guide your purchasing decision. The Benchtop Spectrophotometer YR05476 typically falls within a price range of approximately $14,000 to $15,000 USD, making it a competitive option within its technological bracket. Prices can vary based on suppliers and additional features or services bundled with the device. For precise pricing and potential discounts, contacting Kalstein directly can provide up-to-date information and a detailed quote.

Frequently Asked Questions

What is the primary use of the Benchtop Spectrophotometer YR05476?

The spectrophotometer is mainly used for accurate color analysis and transmission in various industries including paints, textiles, and printing.

Does the spectrophotometer measure both reflectance and transmittance?

Yes, it supports both reflectance and transmittance measurements, allowing for versatile application across different materials and scenarios.

How reliable is the instrument in terms of measurement repeatability?

The YR05476 offers exceptional repeatability, with standard deviations within 0.04% for spectral reflectance and ΔE*ab 0.01 for chromaticity values.

Advantages and Disadvantages

The Benchtop Spectrophotometer YR05476 boasts numerous advantages that make it a compelling choice for laboratory settings. Its flexibility in measuring both reflectance and transmittance allows for comprehensive color analysis, while the variety of supported color spaces ensures thorough and precise evaluation. The device also stands out for its extensive language support and data storage capabilities, accommodating up to 40,000 sample measurements.

However, potential users should consider its size and weight, which may not be ideal for highly mobile settings. Despite this, its stability and durability often offset these concerns, ensuring long-term operation in fixed laboratory environments.

Field Use of the Product

In practical settings, the Benchtop Spectrophotometer YR05476 proves invaluable across industries focused on color quality and consistency. In textile manufacturing, for example, it aids in maintaining color standards from fabric to garment. Within the printing sector, it ensures color precision across different media types, which is crucial for branding and product marketing.

Additionally, the device can be employed during research and development phases to optimize color formulations and assess new product viability efficiently. Its user-friendly interface, coupled with a rapid measuring time of approximately 5 seconds for SCI and SCE, enhances operational efficiencies in fast-paced environments.

Recommendations

To maximize the spectral accuracy and longevity of the Benchtop Spectrophotometer YR05476, regular calibration is essential. Utilize the standard calibration board provided and ensure that the device is stored within the recommended environment to prevent damage. For optimal performance, familiarize yourself with the touchscreen interface and explore the multiple color spaces offered.

Consider enrolling in a brief training session provided by Kalstein, emphasizing proper use and maintenance. Such practice not only prolongs the device’s lifespan but also ensures that it operates at peak efficiency, offering reliable data every time.

If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/benchtop-spectrophotometer-yr05476/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]