Description of the Product
The Benchtop Spectrophotometer YR05476 sets a new standard in color analysis and transmission accuracy for laboratory applications. Designed specifically for industries such as paints, inks, textiles, garments, and printing, this device ensures precise color transfer and quality control. Its innovative design integrates a range of features that enhance its measurement capabilities, making it an indispensable tool for professionals seeking reliability and precision.
One of the standout features of the YR05476 is its optical geometry. It supports reflectance measurements with diffused illumination at an 8-degree viewing angle, and it includes both specular component included (SCI) and specular component excluded (SCE) modes. Transmittance measurements operate with diffused illumination at a 0-degree viewing angle, again supporting SCI and SCE modes. The device conforms to several standards, including CIE No.15, GB/T 3978, and ISO7724/1, ensuring compliance with international measurement criteria. Furthermore, the instrument’s integrating sphere measures 154mm in diameter, providing ample space for diverse sample sizes.
| Model | YR05476 |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 10nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive : Φ30mm/Φ25mm; | |
| Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
| Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
| YI (ASTM D1925, ASTM 313), | |
| MI (Metamerism Index), | |
| Staining Fastness, Color Fastness, Color Strength, Opacity, | |
| 8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) | |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) |
| Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) | |
| Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 |
| (Average for 12 BCRA Series II color tiles) | |
| Dimension | L*W*H=370x300x200mm |
| Weight | Approx. 9.6kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB & Bluetooth & Print serial port |
| Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component |
| Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
| Notes: | The specifications are subject to change without notice. |
Market Price
When considering the acquisition of a high-quality spectrophotometer, understanding the market pricing can guide your purchasing decision. The Benchtop Spectrophotometer YR05476 typically falls within a price range of approximately $14,000 to $15,000 USD, making it a competitive option within its technological bracket. Prices can vary based on suppliers and additional features or services bundled with the device. For precise pricing and potential discounts, contacting Kalstein directly can provide up-to-date information and a detailed quote.
Frequently Asked Questions
What is the primary use of the Benchtop Spectrophotometer YR05476?
The spectrophotometer is mainly used for accurate color analysis and transmission in various industries including paints, textiles, and printing.
Does the spectrophotometer measure both reflectance and transmittance?
Yes, it supports both reflectance and transmittance measurements, allowing for versatile application across different materials and scenarios.
How reliable is the instrument in terms of measurement repeatability?
The YR05476 offers exceptional repeatability, with standard deviations within 0.04% for spectral reflectance and ΔE*ab 0.01 for chromaticity values.
Advantages and Disadvantages
The Benchtop Spectrophotometer YR05476 boasts numerous advantages that make it a compelling choice for laboratory settings. Its flexibility in measuring both reflectance and transmittance allows for comprehensive color analysis, while the variety of supported color spaces ensures thorough and precise evaluation. The device also stands out for its extensive language support and data storage capabilities, accommodating up to 40,000 sample measurements.
However, potential users should consider its size and weight, which may not be ideal for highly mobile settings. Despite this, its stability and durability often offset these concerns, ensuring long-term operation in fixed laboratory environments.
Field Use of the Product
In practical settings, the Benchtop Spectrophotometer YR05476 proves invaluable across industries focused on color quality and consistency. In textile manufacturing, for example, it aids in maintaining color standards from fabric to garment. Within the printing sector, it ensures color precision across different media types, which is crucial for branding and product marketing.
Additionally, the device can be employed during research and development phases to optimize color formulations and assess new product viability efficiently. Its user-friendly interface, coupled with a rapid measuring time of approximately 5 seconds for SCI and SCE, enhances operational efficiencies in fast-paced environments.
Recommendations
To maximize the spectral accuracy and longevity of the Benchtop Spectrophotometer YR05476, regular calibration is essential. Utilize the standard calibration board provided and ensure that the device is stored within the recommended environment to prevent damage. For optimal performance, familiarize yourself with the touchscreen interface and explore the multiple color spaces offered.
Consider enrolling in a brief training session provided by Kalstein, emphasizing proper use and maintenance. Such practice not only prolongs the device’s lifespan but also ensures that it operates at peak efficiency, offering reliable data every time.
If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/benchtop-spectrophotometer-yr05476/.