Product Description
The YR01858 Double Beam UV-VIS Spectrophotometer is a cutting-edge laboratory instrument that enhances precision and reliability in spectrophotometric analysis. Designed with a wavelength range of 190-1100 nm, this spectrophotometer is ideal for a myriad of applications, from routine laboratory analyses to advanced research. The device boasts a spectral bandwidth of 2 nm, ensuring detailed and accurate measurements in every experiment. Its hallmark accuracy of ±0.5 nm makes it a standout choice for laboratories demanding high precision.
What sets the YR01858 apart is its impressive control of stray light, operating at a minimal 0.05% T at 220 nm and 360 nm. The photometric accuracy and repeatability add layers of reliability, making it a trusted tool for researchers worldwide. With a photometric accuracy marked by士0.2% T (0-100% T) and repeatability of ≤0.1% T (0-100% T), users are assured of consistent results. Additionally, the spectrophotometer is equipped with a user-friendly 800*480 touch screen display and a convenient USB data output port, cementing its status as a cutting-edge technology in the field.
| Model | YR01858 | ||
| Wavelength Range | 190-1100nm | ||
| The spectral bandwidth | 2nm | ||
| Wavelength Accuracy | ±0.5nm | ||
| Stray light | 0.05% T @ 220 nm, 360 nm | ||
| Wavelength Repeatability | ≤0.1nm | ||
| Photometric Accuracy |
士0.2%T(0-100%T) ±0.002Abs(0-0.5Abs) ±0.004Abs(0.5-1.0Abs) |
||
| Photometric Repeatability |
≤0.1%T(0-100%T) 0.001Abs(0-0.5Abs) 0.002Abs(0.5-1.0Abs) |
||
| Stability | 士0.001A/h@500nm | ||
| Photometric Range | 0-200%T, -0.3-3.0A, 0-9999C | ||
| Baseline flatness | 士0.001A | ||
| Noise | ±0.0005A | ||
| Display | 800*480 touch screen | ||
| Data Output Port | USB | ||
| Print Port | USB Port | ||
| Light source | Tungsten Lamp & Deuterium Lamp | ||
| Power Requirements | AC 220V/50Hz or AC 110v/60Hz | ||
| Detector | Silicon Photodiode | ||
| Dimension | 460*380*180mm | ||
| Weight | 20KG | ||
Market Price
The market price for high-quality spectrophotometers like the YR01858 generally ranges from around 5000 USD to 6400 USD. This range highlights the device’s value, given its exceptional performance and state-of-the-art features. Potential buyers should consider the investment as the YR01858 offers robust capabilities that justify its price point.
Frequently Asked Questions
What is the primary use of the YR01858 spectrophotometer?
The primary use of the YR01858 spectrophotometer is to measure the absorbance and transmittance of various samples across its defined wavelength range, making it ideal for a wide range of laboratory applications.
How does the double beam technology enhance performance?
Double beam technology provides a significant enhancement by comparing the absorbance of the sample with a reference beam automatically, resulting in more accurate and reliable readings through simultaneous data collection.
Advantages and Disadvantages
Advantages: The YR01858 stands out due to its impressive accuracy and repeatability, user-friendly interface, and comprehensive data output options. Its dual lamp system ensures broad spectrum coverage and reliability in various analytical scenarios.
Disadvantages: As with most advanced laboratory equipment, the initial investment can be substantial. However, the precision and functionality offered justify the cost. Additionally, regular calibration is recommended to maintain peak accuracy, which may incur an additional expense.
Product Use in the Field
The YR01858 Double Beam UV-VIS Spectrophotometer is extensively used in fields such as pharmaceuticals, biochemistry, and environmental sciences. Its ability to precisely measure light absorption and deliver detailed analysis makes it invaluable for quantifying the concentration of substances in various research settings. Laboratories utilize this device in the analysis of complex compounds to ensure compliance with scientific standards.
Researchers appreciate the spectrophotometer for its robust performance under consistent laboratory conditions, enabling intricate experiments to be carried out efficiently. Its expansive wavelength range also allows analysts to examine a broad spectrum of samples, providing greater versatility in research and development projects.
Recommendations
To maximize the utility of the YR01858 spectrophotometer, it’s crucial to ensure regular maintenance and calibration. Users should operate the instrument in a dust-free environment to protect optical components and maintain clarity in readings. Additionally, taking advantage of online tutorials and support from the manufacturer can enhance user proficiency.
Those interested in exploring the capabilities of the YR01858 spectrophotometer should consider reaching out for a demonstration or requesting a quote through the Kalstein Plus platform. This presents an opportunity for hands-on experience and a deeper understanding of the features that make this instrument indispensable.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our online purchasing channels, intuitive and agile, are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life, it is time to be part of our community. https://kalstein.net/en/product/double-beam-uv-vis-spectrophotometer-yr01858/.