Product Description
The Laminar Flow Clean Bench YR05728 stands out as a cornerstone in laboratory equipment design, delivering a pristine work environment. This state-of-the-art bench is engineered to maintain an exceptional cleanliness level of Class 100 at particles ≥0.5μM, ensuring that the most stringent requirements of the US Federal 209E standards are met. It effectively limits the number of colonies to ≤0.5pcs/dish·hour on a Φ90mm culture plate, which is critical for maintaining uncompromised experimental integrity.
Engineered for precise performance, the YR05728 boasts an average wind speed ranging from 0.25~0.45m/s, which ensures optimal airflow to protect sensitive processes from contamination. The maximum noise level is a whisper-quiet ≤62dB(A), providing a comfortable working environment for lab professionals. Additionally, the bench minimizes distractions caused by vibrations with a vibration half peak of ≤5μM across x, y, and z axes. The workspace is illuminated with ≥300Lx, creating a well-lit environment conducive to precise work.
| Model | YR05728 |
| Cleanliness Level | Class 100@≥0.5μM (US Federal 209E) |
| Number of Colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
| Average Wind Speed | 0.25~0.45m/s |
| Noise | ≤62dB(A) |
| Vibration half peak | ≤5μM(x、y、z direction) |
| Illuminance | ≥300Lx |
| Power Supply | AC single phase 220V/50Hz |
| Maximum Power | 490W |
| Weight | 90kg |
| Work area size W1×D1×H1 | 880×510×580 1040×690×1600 |
| Dimensions | Single/Single |
| High-efficiency filter specification and quantity | 850×565×50 |
Market Price
The Laminar Flow Clean Bench YR05728 is competitively priced within the market. Generally, the price range for similar high-performance laminar flow benches spans from approximately $1500 to $2300 USD, making the YR05728 an exceedingly attractive option due to its quality and efficiency. This pricing tier ensures that laboratories invest wisely in equipment offering long-term reliability and performance.
Frequently Asked Questions
What type of laboratories is the YR05728 suitable for?
The YR05728 is suitable for a variety of laboratories, including those specializing in microbiology, pharmaceuticals, and electronics, where contamination control and cleanliness are critical.
How does the model ensure maximum cleanliness?
This unit maintains a cleanliness level of Class 100 by utilizing high-efficiency filters and a controlled laminar airflow, ensuring a contaminant-free environment.
What are the maintenance requirements?
Routine maintenance includes regular filter changes and checks to maintain optimal airflow and cleanliness. The user manual provides a detailed maintenance schedule.
Advantages and Disadvantages
Advantages:
- High-level cleanliness suitable for sensitive applications.
- Low noise and vibration levels enhance user comfort and focus.
- Reliable illuminance for detailed work precision.
- Energy-efficient design with a maximum power consumption of 490W.
Disadvantages:
- The initial investment may be significant for smaller laboratories.
- Size and weight (90kg) may require allocated space and installation planning.
Product Use in the Field
In practical applications, the YR05728 is leveraged to create contaminant-free zones ideal for tasks like sterile media plate preparations, semiconductor assembly, and processing of critical components in biotechnology. Professionals in these fields rely on such a device to adequately protect their samples and ensure the utmost accuracy in their results. The bench facilitates the smooth functioning of tasks that demand a sterile environment by preventing microbial and particulate interference.
Moreover, when employed in pharmaceutical settings, the bench is indispensable for compound preparation, aiding in the safe formulation of medications without external contamination. Its application extends to any scenario requiring a clean zone within research or quality control sectors.
Recommendations
To maximize the YR05728’s potential, it is recommended to place the unit in a laboratory area dedicated to critical tasks to minimize interference from foot traffic and inadvertent contaminants. Regular monitoring of airflow rates and cleanliness levels ensures consistent performance. Users should keep the manual accessible and periodically verify the correct operation of the bench’s components, such as the filters and fan system.
Scheduling regular maintenance checks and keeping spare parts at hand can prevent unforeseen downtimes, safeguarding continuous laboratory operations. Lastly, utilizing the innovative features of the YR05728 will not only protect sensitive processes but also enhance the productivity and safety of laboratory operations.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your comfort, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life; it’s time to become part of our community. https://kalstein.net/en/product/laminar-air-flow-clean-bench-yr05728/.