In the world of laboratory equipment, the Horizontal Pulsating Vacuum Autoclave stands as a pinnacle of innovation and efficiency. The models YR05651 to YR05654-1 present a blend of advanced technology and meticulous design, catering to the rigorous demands of modern laboratories. This comprehensive guide delves into the intricacies of these autoclaves, exploring their technical specifications and unrivaled features.
Product Description
The Horizontal Pulsating Vacuum Autoclave series, encompassing models YR05651, YR05651-1, YR05652, YR05652-1, YR05653, YR05653-1, YR05654, and YR05654-1, boasts a seamless amalgamation of state-of-the-art design and precise engineering. These autoclaves operate under a design pressure of -0.1/0.3Mpa with a temperature range of 105℃ to 139℃, delivering sterilization processes with exceptional accuracy. Designed for an effortless front-loading experience, these autoclaves feature an automatic vertical sliding door, adding to their user-friendliness and operational safety.
The autoclaves come equipped with a 7-inch color touch screen paired with a PLC+HMI control system for intuitive operation. The built-in printer ensures seamless documentation, while the multilingual display (available in English, Spanish, and Chinese) caters to a wide array of users. Embedded within these machines are key components such as a water tank, water pump, and steam generator, enhancing their self-sufficiency and reliability.
| Model | YR05651 | YR05651-1 | YR05652 | YR05652-1 | YR05653 | YR05653-1 | YR05654 | YR05654-1 |
| Design pressure | -0.1/0.3Mpa | |||||||
| Design temperature | 150℃ | |||||||
| Working temperature range | 105℃-139℃ | |||||||
| Working pressure range | 0-0.25Mpa | |||||||
| Temperature control accuracy | ≤ ± 0.2℃ | |||||||
| Temperature display accuracy | 0.1℃ | |||||||
| Sterilization time range | 0-999min | |||||||
| Drying time range | 0-999min | |||||||
| Vacuum rate | -97Kpa | |||||||
| Temperature equilibrium | ≤±0.5℃ | |||||||
| Safety valve open pressure | 0.28Mpa | |||||||
| Water source | 0.15-0.3MPa | |||||||
| Steam pressure | 0.2-0.6Mpa | |||||||
| Compressed air source | 0.4MPa-0.7MPa | |||||||
| Door Number | Single Door | Double Door | Single Door | Double Door | Single Door | Double Door | Single Door | Double Door |
| Sterilization capacity Capacity | 400 L | 450 L | 600 L | 800 L | ||||
| Size | 652*700*900 | 652*700*1000 | 652*700*1320 | 652*700*1750 | ||||
| Type | Front loading fully automatic horizontal autoclave | |||||||
| Class | Class B | |||||||
| Door type | Automatic vertical sliding door | |||||||
| Control | PLC + HMI + Printer | |||||||
| Display | 7.0 inch color touch screen | |||||||
| Additional Features | Built-in printer Warranty: 2 years Language: English, Spanish, Chinese Built-in water tank Built-in water pump Built-in steam generator |
|||||||
Market Price
When considering the acquisition of a high-performance Horizontal Pulsating Vacuum Autoclave, potential buyers should expect a market price ranging between $34,400 to $35,200 USD. These figures reflect the autoclave’s state-of-the-art design and robust performance, providing excellent value for laboratories seeking reliable and efficient sterilization solutions.
Frequently Asked Questions
How does the automatic vertical sliding door enhance safety?
The automatic vertical sliding door is designed to reduce manual handling, thereby minimizing human error and enhancing operator safety.
What is the capacity range of these autoclaves?
The series offers a range of sterilization capacities from 400 liters to 800 liters, catering to diverse laboratory needs.
Can the autoclave be operated by non-English speakers?
Yes, the autoclave interface is multilingual, offering English, Spanish, and Chinese to accommodate a broad user base.
Advantages and Disadvantages
Among the many advantages of the Horizontal Pulsating Vacuum Autoclave are its impressive precision in temperature control and robust safety features. The built-in components, such as the steam generator and water pump, underscore its self-sufficient operation. However, the complexity of its advanced features may require specialized training for optimal use and maintenance.
A potential disadvantage is the initial cost, which may be higher than simpler models. Nonetheless, the long-term reliability and efficiency offset the initial investment, making it a worthwhile addition to any lab.
Product Use in the Field
These autoclaves find their application in various laboratory settings where sterilization is paramount. From hospital labs ensuring the sterilization of surgical instruments to pharmaceutical industries maintaining sterile processing environments, their adaptability across fields is unmatched. They streamline workflows through reliable automation, drastically reducing downtime and increasing throughput.
The autoclaves’ PLC and HMI controlled processes coupled with a high-resolution touch screen enable seamless operation, crucial in fast-paced environments.
Recommendations
To maximize the efficiency and lifespan of the Horizontal Pulsating Vacuum Autoclave, regular maintenance and calibration checks are recommended. Ensure that only trained personnel operate the autoclave to prevent mismanagement. Additionally, integrating routine validation processes will ensure that the autoclave continues to meet stringent laboratory standards.
If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/horizontal-pulsating-vacuum-autoclave-automatic-vertical-sliding-door-yr05651-yr05654-1/.