Advanced Technical Insights on Drug Stability Test Chambers

Product Description

The ALLIGENT-KG Comprehensive Drug Stability Test Chamber stands out as a pivotal instrument in pharmaceutical environments. Engineered to provide stringent control over temperature, humidity, and lighting conditions, it ensures the stability and effectiveness of drugs during testing phases. This chamber, available in models YR05354, YR05355, and YR05356, features a forced convection system coupled with a thirty-stage microprocessor PID controller for precise environmental control.

Temperature settings range from 10~65℃ with lighting, and 0~60℃ without, offering an impressive temperature accuracy of 0.1℃. Such precision is further supplemented by a fluctuation margin of ±0.5℃ and uniformity ranging from ±1 to ±1.5, depending on the model. The humidity range of 50~90%RH with a fluctuation of ±3%RH ensures that a controlled environment is maintained throughout the testing process.

Product Model
ALLIGENT-KG
Comprehensive drug stability test chamber
YR05354
YR05355
YR05356
Convection Mode
Forced Convection
Control System
Thirty stages Microprocessor PID controller
Temp. Range
10~65℃(with lighting)/0~60℃(without lighting)
Temp. Accuracy
0.1℃
Temp. Fluctuation (10-40℃)
±0.5℃
Temp. Uniformity(10-40℃)
±1
±1
±1.5
Humidity Range
Humidity Range: 50~90%RH, Humidity Fluctuation: ±3%RH
Illumination Range
0~6000LX (five stages adjustable)
Working Environment
Ambient temperature: 10~30℃, Humidity <70%
Insulation materials
Imported environmental protection type material
External Dimensions (H×W×D)
1410×650×680
1730×650×740
1700×745×930
Internal Dimensions (H×W×D)
760×510×390
1100×510×450
1050×600×640
Interior Volume (L)
150
250
400
Interior Steel Materials
Interior steel materials
Power Consumption (W)
1080
1100
1350
Power Supply
AC220V/50Hz
Net Weight (KG)
107
135
158
Shipping Weight (KG)
132
162
186
Shipping Dimensions (H×W×D)
1610×750×830
1930×750×890
1900×840×1080

Market Price

The market price for a drug stability test chamber of this caliber typically ranges between USD 10,800 and USD 11,600. This pricing spectrum reflects the advanced technology and high-reliability standards embedded in the ALLIGENT-KG models. Such an investment assures consistent quality and precise management of testing conditions, making it indispensable for any laboratory focused on drug development and testing. At Kalstein, we strive to maintain competitive pricing while delivering unparalleled service and support.

Frequently Asked Questions

What is the temperature accuracy of the ALLIGENT-KG models?

The temperature accuracy of these models is exceptionally high, with precision up to 0.1℃.

Can the chamber be used in environments with varying ambient temperatures?

Yes, the chamber is designed to operate effectively within an ambient temperature range of 10~30℃, catering to diverse laboratory settings.

What type of materials are used for insulation and construction?

We use imported environmentally friendly materials for insulation, and the interior is made with high-quality steel for durability and safety.

Is there an auto-quotation feature for purchasing?

Yes, you can easily generate an automatic quotation through our Kalstein Plus platform. This feature allows you to explore your purchasing options conveniently.

Advantages and Disadvantages

The ALLIGENT-KG drug stability test chambers offer numerous advantages, such as reliable temperature and humidity control, efficient power consumption, and robust construction with high-grade materials. These features enhance the accuracy and reproducibility of stability testing processes. Additionally, the intuitive control system simplifies operations for users.

However, potential buyers should consider the initial investment cost, as it might be significant for smaller laboratories with limited budgets. The physical size of the chambers may also require careful space planning in compact lab environments. Despite these considerations, the benefits far outweigh the limits, making it an essential tool for many research institutions.

Product Use in the Field

The ALLIGENT-KG Comprehensive Drug Stability Test Chamber is widely used in pharmaceutical development, aiding researchers and scientists in evaluating the shelf life and optimal storage conditions for new medications. By simulating various environmental conditions, it helps predict drug stability over extended periods, ensuring their safety and efficacy for consumers. Both production and R&D laboratories find this equipment integral for performing standardized and regulated stability assessments.

Additionally, it facilitates compliance with industry standards by providing controlled testing environments that mimic real-world storage and transportation scenarios, ensuring thorough and dependable results for pharmaceutical compounds.

Recommendations

For optimal use and longevity of the ALLIGENT-KG stability test chamber, regular maintenance is advised. This includes checking sensor calibrations and ensuring that the internal environment remains free of contaminants that could affect testing results. Users should also follow the manufacturer’s guidelines for scheduling comprehensive system checks and updates.

To maximize efficiency, consider integrating these chambers into a larger workflow process, leveraging their precision for rigorous quality control procedures. This integration is critical for maintaining the highest standards in pharmaceutical development and reducing the time to market for new drugs.

If you are seeking a blend of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with an excellence level. Our online purchasing channels, intuitive and agile, are designed for your convenience, ensuring the friendliest prices. Hesitate no longer, we bring science to life—it’s time to be a part of our community. https://kalstein.net/en/product/comprehensive-drug-stability-test-chamber-yr05354-yr05356/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]