Product Description
The Multifunctional Imager YR06210 and YR06211 are cutting-edge tools designed for advanced scientific imaging applications. These imagers are engineered to support a wide range of laboratory tasks, including Chemilluminescence Imaging, ECL Western Blotting, Fluorescence Imaging, and Gel Documentation. Both models are ideal for detecting DNA/RNA and protein gels using state-of-the-art imaging technology.
Model YR06210 features a Back Illuminated SCMOS Sensor with a resolution of 9.0 Megapixels and pixel size of 3.76 × 3.76 μm, whereas the YR06211 is equipped with a Front Illuminated CCD Sensor with 6 Megapixels and a pixel size of 4.54 x 4.54 μm. These imagers maintain a regulated temperature of -30°C and provide a dynamic range of 4.8 OD. With a pixel density of 16-bit (65,536 Grey scales), they ensure precise imaging for detailed analysis.
Their advanced lens specification, offering an F0.95 standard with auto-focus, ensures sharp images over a range of conditions. These systems are accompanied by features such as an electronic lifting platform for accommodating different sized western blotting membranes and specialized LED transmission methods for both DNA/RNA and protein gel detection. Additionally, the SHST Capture and Analysis Software included offers unparalleled processing capabilities for unlimited users.
Model | YR06210 | YR06211 | |
Application | Chemilluminescence Imaging, ECL Western Blotting | YES | YES |
Fluorescence Imaging, Fluorescent Western Blotting | YES | YES | |
Gel Doc Application | YES | YES | |
Protein gel; SDS Pages | YES | YES | |
Standard Parameters | Sensor | Back illuminated SCMOS Sensor | Front illuminated CCD Sensor |
Resolution | 9.0Megapixels | 6 Megapixels | |
Pixel Size | 3.76 × 3.76 μm | 4.54 x 4.54 μm | |
Temperature | -30 °C regulated | ||
Dynamic Range | 4.8OD | ||
Pixel density | 16bit(65536 Grey scales) | ||
Lens | F0.95 as standard (optional F0.8) Auto focus | ||
Chemilluminescence Sample tray | Electronic Lifting Platform for diverse sizes of western blotting membranes | ||
DNA/RNA detection | Electronic Lifting Blue LED Transmission for DNA/RNA detection | ||
Protein gel; SDS Pages | Electronic Lifting White LED Transmission for Protein Gels | ||
Software | SHST Capture and Analysis Software for unlimited number of users | ||
Optional Accessories | Epi-UV, RGB and NIR fluorescent detection | ||
Removable industrial computer, 13.1 Inch Touch Screen, Intel processor |
Market Price
The market price for the Multifunctional Imager models YR06210 and YR06211 ranges from approximately $26,000 to $26,500 USD. This range takes into account the variable factors such as optional features and accessories that can enhance the functionality of these imagers, offering flexibility in terms of budget and customization according to specific lab needs.
Frequently Asked Questions
What applications are supported by the Multifunctional Imager?
The Multifunctional Imager supports a wide array of applications, including Chemilluminescence Imaging, ECL Western Blotting, Fluorescence Imaging, and Gel Documentation, among others.
What are the key sensor differences between models YR06210 and YR06211?
Model YR06210 utilizes a Back Illuminated SCMOS Sensor with 9 Megapixels resolution, while YR06211 features a Front Illuminated CCD Sensor with a resolution of 6 Megapixels.
Is the software included with the imager user-friendly?
Yes, the SHST Capture and Analysis Software is designed for ease of use and provides capabilities for an unlimited number of users.
What are the compatibility options for additional accessories?
The imagers can be equipped with optional accessories like Epi-UV, RGB, and NIR fluorescent detection systems for enhanced versatility.
Advantages and Disadvantages
Advantages: The Multifunctional Imager offers high-resolution imaging quality, versatile application support, and excellent sensor technology, making it indispensable for modern laboratories. Its advanced features such as electronic lifting platforms and easy-to-use software enhance usability and efficiency.
Disadvantages: The initial investment may be considerable depending on added features and accessories. Additionally, the equipment’s advanced technology may require training for some users to fully exploit its capabilities.
Use of the Product in the Field
The Multifunctional Imager is employed extensively in biological and chemical laboratories for precise imaging needs. Researchers use it to obtain high-definition images for detailed analysis of Western blotting results, protein and nucleic acid detection, among other crucial laboratory tasks. Its adaptability and comprehensive functionality make it a go-to instrument in various scientific settings.
By leveraging its accurate imaging technology and diverse applications, labs can conduct complex analyses more efficiently, leading to accelerated research outcomes and breakthroughs.
Recommendations
To ensure optimal performance and longevity of the Multifunctional Imager, regular maintenance and calibration are recommended. Users should conduct periodic checks on the sensor and imaging outputs to maintain its precision. It is beneficial to take advantage of the full software capabilities for comprehensive data analysis and to familiarize all users thoroughly with the system to maximize utility.
If you’re looking for innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate anymore, we bring science to life; it is time to become part of our community. https://kalstein.net/en/product/multifunctional-imager-yr06210-yr06211/.