Product Description
The Biological Safety Cabinets YR05708 to YR05710 by Kalstein stand out for their modern design and advanced technology, crucial for maintaining a sterile environment in laboratory settings. These cabinets provide Class 100 cleanliness in compliance with the US Federal 209E standards, ensuring that contaminants are controlled effectively. They achieve optimal performance with a particle count of ≤0.5pcs/dish·hour within a 90mm culture plate.
Remarkably efficient, these cabinets maintain specific average wind speeds to optimize air quality. Wind speed measurements include 0.38±0.025m/s inside the door, 0.26±0.025m/s in the middle, and 0.27±0.025m/s inside the cabinet, with a front suction wind speed of 0.55m±0.025m/s. Despite these high-performance standards, the noise level is kept at a minimal ≤65dB(A). Operational efficiencies are enhanced with an AC single-phase 220V/50Hz voltage across the models, and power consumption varies slightly between the models, with maximum power forms ranging from 500W to 700W.
Constructed for durability and space optimization, model weights vary from 210KG to 270KG, and working area dimensions differ among the models, from 1040×650×620 to 1640×650×620. These cabinets also incorporate high-efficiency filters and UV lamps, adapted to provide additional precaution against contaminants. Fluorescent lamp configurations differ slightly to adapt to varying operational needs, ensuring ease in observing and working within the cabinet.
| Model | YR05708 | YR05709 | YR05710 | |
| Cleanliness | Class 100@≥0.5μm (US Federal 209E) | |||
| Number of colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) | |||
| average wind speed | Inside the door | 0.38±0.025m/s | ||
| middle | 0.26±0.025m/s | |||
| Inside | 0.27±0.025m/s | |||
| Front suction wind speed | 0.55m±0.025m/s | |||
| noise | ≤65dB(A) | |||
| Voltage | AC single-phase 220V/50Hz | |||
| Maximum power consumption | 500W | 600W | 700W | |
| Weight | 210KG | 250KG | 270KG | |
| Working area W1×D1×H1 | 1040×650×620 | 1340×650×620 | 1640×650×620 | |
| Overall dimension W×D×H | 1200×800×2270 | 1500×800×2270 | 1800×800×2270 | |
| High efficiency filter specification and quantity | 980×490×50×1 | 1280×490×50×1 | 1580×490×50×1 | |
| 520×380×70×1 | 820×380×70×1 | 1120×380×70×1 | ||
| Specification and quantity of fluorescent lamp/ultraviolet lamp | 20W×2/20W×1 | 30W×2/30W×1 | 30W×2/30W×1 | |
Market Price
Understanding the investment required for high-quality laboratory equipment is crucial. The market price for biological safety cabinets such as the YR05708 to YR05710 series ranges between USD 6,500 and USD 7,750. This range ensures that you are investing in a product that combines robustness, exceptional operational capability, and advanced safety measures—all necessary for top-notch laboratory standards.
Frequently Asked Questions
What Class does the Biological Safety Cabinet belong to?
The YR05708 to YR05710 series cabinets belong to Class 100, adhering to US Federal 209E standards, which assures a high level of air cleanliness.
What are the voltage and power requirements for these models?
These cabinets require an AC single-phase 220V/50Hz voltage. Maximum power consumption varies slightly across the models, ranging from 500W to 700W.
Are these cabinets noisy during operation?
No, the cabinets operate at a noise level of ≤65dB(A), ensuring a quiet working environment.
Are UV lamps included in the setup?
Yes, the cabinets are equipped with fluorescent as well as ultraviolet lamps to enhance sterilization processes within the working area.
Advantages and Disadvantages
Advantages: The YR05708 to YR05710 biological safety cabinets offer superior air cleanliness and particle control, comply with rigorous international standards and have an intuitive design that enhances user operation and reliability. They ensure minimal environmental noise and are effective in reducing bio-hazardous threats.
Disadvantages: These high-efficiency models require a specific voltage input, which may necessitate additional setup in some laboratories. The significant weight of the cabinets could be an issue if regular relocation is anticipated.
Product Use in the Field
These biological safety cabinets are indispensable in microbiology labs, pharmaceutical industries, and clinical environments where maintaining a sterile environment is critical. Their air filtration efficiency and minimal disturbance level make them ideal for a wide range of applications including sample preparation, tissue culture, and cell biology research.
Furthermore, the large working area and clear visibility provided by the UV-protected glass screens facilitate precise work handling and visual inspection, advancing exacting scientific research processes and outcomes.
Recommendations
To maximize the use and extend the lifespan of your YR05708 to YR05710 biological safety cabinet, regular maintenance and calibration should be performed. Ensure daily checks of UV lamp functionality and clean high-efficiency filters routinely to maintain airflow and sterilization efficacy. Additionally, integrate calibration into your safety protocol and optimize the cabinet placement in a controlled environment to avoid airflow disruption.
If you are searching for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your comfort, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life; it is time to become part of our community. https://kalstein.net/en/product/biological-safety-cabinet-yr05708-yr05710/.