Electrosurgical Generator YR02147: Redefining Precision in Surgery

Product Description

The Electrosurgical Generator YR02147 is a cutting-edge medical device designed to enhance surgical precision and patient outcomes through its sophisticated technology and versatile functionality. Engineered for both monopolar and bipolar operations, the YR02147 model operates at a maximum power and rated load across various cutting and coagulation modes. The device features a monopolar pure cut and blend 1 mode with a power rating of 60W/500Ω and 50W/500Ω, respectively, providing surgeons with the flexibility required for diverse surgical tasks.

In addition, the YR02147 supports standard coagulation and bipolar operations, with settings for bipolar cut and coagulation both offering 40W/100Ω. The device ensures minimal thermal damage and promotes fast healing by utilizing specific measuring frequencies of 4.0MHZ ±2% for monopolar and 1.84MHZ ±2% for bipolar modes, highlighting its reliability and accuracy in the operating room.

Model YR02147
Working Mode Max Power / Rated Load
Monopolar Cut Pure cut 60W / 500Ω
Blend 1 50W / 500Ω
Monopolar Coag Standard Coag 50W /500Ω
Bipolar Cut Bipolar Cut 40W / 100Ω
Bipolar Coag Bipolar Coag 40W / 100Ω
Electrical requirement Monopolar Measuring Frequency 4.0MHZ ±2%
Bipolar Measuring Frequency 1.84MHZ ±2%
Max Input Currency 1400VA
Environmental Conditions for Use Condition Range
Temperature 50°C to 40°C
Relative humidity ≤ 95% non-condensing
Pressure 700 hPa to 1060 hPa

Market Price

The Electrosurgical Generator YR02147 is competitively priced within the medical equipment market, with a general range between $3,900 and $4,700 USD. This range reflects the cutting-edge technology and advanced features that the device offers, making it a valuable investment for healthcare facilities looking to enhance their surgical capabilities.

Potential buyers and medical institutions can find the YR02147 available across multiple platforms, including specialized medical equipment websites and direct purchasing through established distributors. The varied pricing helps accommodate different budgets, while ensuring access to this high-performance device.

Frequently Asked Questions

What is the maximum power capacity of the YR02147?

The Electrosurgical Generator YR02147 offers a maximum power of 60W for monopolar pure cut operations, while providing 40W for bipolar cut and coagulation modes.

Is the YR02147 suitable for all types of surgeries?

Yes, the YR02147 is versatile and suitable for a wide range of surgical procedures, thanks to its multiple cutting and coagulating modes and adjustable power settings.

What are the recommended environmental conditions for using this device?

The recommended operating temperature ranges from 50°C to 40°C, with relative humidity not exceeding 95% non-condensing, and a pressure range between 700 hPa to 1060 hPa.

Advantages and Disadvantages

Advantages: The YR02147 offers precision and versatility crucial for modern surgical procedures. With adjustable settings for various surgical needs, the device ensures minimal thermal damage, promoting faster recovery and reduced complications for patients.

Disadvantages: While the YR02147 is highly advanced, its complexity might require additional training for some surgical teams to fully exploit its capabilities. Additionally, the initial investment can be significant for some smaller facilities.

Field Usage

In real-world surgical environments, the Electrosurgical Generator YR02147 excels in providing surgeons with reliable, precise cutting and coagulation capabilities required for diverse procedures. The device enhances precision in both open and laparoscopic surgeries, allowing for efficient tissue management and reduced intraoperative bleeding.

Its reliability ensures that surgeons can focus on patient outcomes, knowing that they have a dependable tool that enhances their expertise. The ability to switch between monopolar and bipolar modes seamlessly also makes it an indispensable piece of equipment in multi-specialty surgical settings.

Recommendations

To maximize the performance and longevity of the YR02147, it is recommended to regularly inspect and maintain the device according to the manufacturer’s guidelines. Ensure that all staff members are adequately trained on operating procedures and safety practices to minimize risks during surgical interventions.

When using the device, always adhere to the specified environmental conditions to avoid potential damage and ensure consistent performance. Regular updates and calibration checks are also vital to maintaining the precision that the YR02147 is known for, thus ensuring optimal patient care at all times.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every piece of equipment with a level of excellence. Our intuitive and fast online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it is time to be part of our community. https://kalstein.net/en/product/electrosurgical-generators-yr02147/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]