Innovative Pulled Xenon Lamp Spectrophotometer: Advanced Technical Excellence

Product Description

The YR05475 Pulled Xenon Lamp Spectrophotometer stands as a pinnacle of innovation and precision for laboratory applications. This cutting-edge device is engineered with a reflectance optical geometry of d/8 and transmittance optical geometry of d/0, conforming to a range of international standards including CIE No.15 and ISO7724/1, among others. Crafted for superior performance, it seamlessly accommodates SCI&SCE measurements, incorporating UV and excluding UV options for versatile usability.

Featuring an integrating sphere size of 154mm, the spectrophotometer utilizes a sophisticated light source apparatus, incorporating a xenon lamp with a wavelength capacity ranging from 360nm to 780nm. The inclusion of a 400nm cut-off ensures enhanced flexibility and accuracy in diverse applications. Additionally, its spectrophotometric mode is elevated by the inclusion of a concave grating, contributing to unparalleled measurement precision. The sensor system supports an extensive wavelength range of 360-780nm, maintaining a wavelength pitch of 10nm and a semiband width of 5nm, providing comprehensive spectral data collection.

Technical Specifications

Model YR05475 (Pulsed xenon lamp)
Optical Geometry Reflectance: d/8 (SCI⪰ Include UV/Exclude UV)
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003)
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size Φ 154mm
Light Source Device 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360-780nm
Wavelength Pitch 10nm
Semiband Width 5nm
Reflectance Range 0~200%
Measuring Aperture Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component Reflectance: SCI&SCE
Transmittance: SCI&SCE
Color Space CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy
Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99
Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle 2° & 10°
Illuminants D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed Data Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
Measuring Time About 2.4s (Measure SCI & SCE about 5s)
Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
Size 370×300×200mm
Weight About 9.6kg
Power Supply DC 24V, 3A Power Adapter
Light Source Device Life 5 years, more than 3 million times measurements.
Display 7″ TFT Capacitive Screen-touch Display
Data Port USB & Print serial port
Data Storage Standard 2000 Pcs, Sample 20000 Pcs
Language Simplified Chinese, Traditional Chinese, English,
Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation)
Storage Environment Temperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard Accessory Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber,
Optional Accessory Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Market Price

The market for high-precision pulsed xenon lamp spectrophotometers places these devices within an upper range of laboratory equipment pricing. This spectrophotometer is typically priced around USD 10,000 to USD 11,200, reflecting its advanced features and reliable performance metrics. Factors influencing the pricing include technological capabilities, brand reliability, and support services provided by manufacturers like Kalstein.

Frequently Asked Questions

What types of measurements can this spectrophotometer perform?

The YR05475 model can perform both reflectance and transmittance measurements, including UV-inclusive and UV-exclusive options.

How does the xenon lamp improve the spectrophotometer’s functioning?

The pulsed xenon lamp enhances measurement precision by providing stable and consistent light sources, essential for accurate colorimetric and spectral data.

Is the device suitable for standardized testing?

Yes, it conforms to several international standards including CIE, ISO, and ASTM ensuring compatibility with standardized testing requirements.

Advantages and Disadvantages

Advantages: The YR05475 spectrophotometer stands out for its superior measurement precision supported by a xenon light source and compliance with international standards. Its versatile measurement modes offer adaptability across various testing requirements, and its automatic calibration features reduce operational errors, contributing to consistent results.

Disadvantages: One of the trade-offs for possessing such advanced equipment could be its initial cost. Additionally, the device’s complexity may require specialized training or user adaptation, although this is often the case with high-tier scientific instruments.

Field Usage

This spectrophotometer is specifically designed for rigorous laboratory applications where precision is paramount. It’s widely used in industries ranging from textiles and plastics to coatings and printing, where measuring the color accuracy and consistency of materials is required. The dual ability to measure reflectance and transmittance facilitates comprehensive analyses and supports a broad array of scientific inquiries and production assessments.

Recommendations

To maximize the efficiency and lifespan of the YR05475 spectrophotometer, regular calibration using the provided standard calibration board is recommended. Users should familiarize themselves with the guiding documentation and software tools included with the device. Ensuring an appropriate environment that minimizes dust and spikes in humidity can further preserve device accuracy and functionality. Investing in the optional micro-printer or transmissive test components might also enhance its versatility according to specific needs.

If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/pulsed-xenon-lamp-benchtop-spectrophotometer-yr053405/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]