State-of-the-Art YR05726 Laminar Flow Cabinet: A Game Changer in Laboratory Purity

Product Description

The YR05726 Class 100 Horizontal Air Laminar Flow Cabinet epitomizes cutting-edge laboratory technology, ensuring precision and protection in sensitive research environments. Designed to meet the stringent Class 100@≥0.5μM (US Federal 209E) cleanliness standards, this advanced laminar flow cabinet provides an unrivaled safe environment for delicate laboratory tasks.

With an average wind speed of 0.25~0.45m/s and a noise level limited to ≤62dB(A), this cabinet offers a serene workspace free from potential airborne contamination. The vibration half-peak sensitivity (≤5μM in x, y, z directions) coupled with an illuminance of ≥300Lx ensures all your laboratory operations are conducted smoothly with optimal visibility.

For seamless operation, the cabinet is powered by an AC single phase 220V/50Hz system with a maximum power consumption of 100W. This energy efficiency is paired with practical design specifications, including a work area size of 700×410×580 mm and overall dimensions of 860×590×1600 mm, making it a practical addition to any laboratory space. For filtration, it utilizes a high efficiency filter with specifications of 680×565×50. The lighting system includes a 12W fluorescent lamp and a 20W ultraviolet lamp, ensuring a well-lit workspace without compromising on purity or performance.

Model YR05726
Cleanliness Level Class 100@≥0.5μM (US Federal 209E)
Number of Colonies ≤0.5pcs/dish·hour (Φ90mm culture plate)
Average Wind Speed 0.25~0.45m/s
Noise ≤62dB(A)
Vibration Half Peak ≤5μM (x、y、z direction)
Illuminance ≥300Lx
Power Supply AC single phase 220V/50Hz
Maximum Power 100W
Weight 80Kg
Work Area Size W1×D1×H1 700×410×580
860×590×1600
Dimensions Single/Single
High Efficiency Filter Specification and Quantity 680×565×50
Specification and Quantity of Fluorescent Lamp/Ultraviolet Lamp 12W×1
20W×1

Market Price

When considering the acquisition of a high-performance laminar flow cabinet like the YR05726, it is crucial to evaluate the market pricing landscape. This advanced equipment is generally available within a price range of $1000 to $1800 USD, encapsulating precision engineering and reliability. This investment reflects its robust features which are indispensable for ensuring sterile conditions in laboratory settings. Prospective buyers are invited to explore pricing opportunities and potential discounts through the convenient Kalstein Plus platform, ensuring they secure an economical purchase while accessing premium technology.

Frequently Asked Questions

What are the power requirements for the YR05726 Laminar Flow Cabinet?

This cabinet operates on a standard AC single phase 220V/50Hz, making it compatible with most laboratory power setups.

How does the cabinet maintain sterile conditions?

The YR05726 ensures a sterile environment with its Class 100 cleanliness level, achieved through efficient airflow and a high efficiency filter that traps contaminants.

Is the cabinet noisy during operation?

Not at all. The cabinet maintains a noise level of ≤62dB(A), ensuring a quiet working environment.

Advantages and Disadvantages

One of the primary advantages of the YR05726 is its rigorous adherence to Class 100@≥0.5μM (US Federal 209E) standards, providing unmatched protection against contamination. The efficient airflow and filtration system enhance its capability, ensuring precision and reliability in scientific exploration.

However, a potential drawback could be its initial cost, which, while justified by its features, might represent a significant upfront investment for smaller laboratories. Despite this, its long-term value and performance efficiency make it a worthwhile consideration.

Field Use of the Product

The YR05726 Laminar Flow Cabinet is ideal for settings requiring immaculate control over contamination levels. It finds extensive application within microbiology, biotechnology, and chemical laboratories, where sensitive experiments are conducted under tightly regulated conditions. The cabinet’s precise airflow controls and vibration dampening ensures experiments can be conducted without undue interference, guaranteeing reliable results every time.

Moreover, its use extends to industries where particulate and microbial control is non-negotiable, such as in pharmaceuticals and even in electronics where highly sensitive components are assembled.

Recommendations

To optimize the performance of the YR05726, it is recommended to regularly check and replace the filters as per the manufacturer’s guidelines to maintain airflow efficiency. It is also wise to conduct routine cleanliness checks to ensure any possibility of contamination is promptly addressed.

Allowing enough space around the cabinet for air circulation will further enhance its functionality, while periodic maintenance by trained personnel can prolong its lifespan and reliability.

If you are looking for a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate anymore; we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/class-100-horizontal-air-laminar-flow-cabinet-yr05726/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]