Product Description
The Infant Incubator YR02187 is a state-of-the-art medical device designed to provide optimal environmental conditions for newborns needing extra care. With its high-precision skin and air temperature control, it ensures that premature or critically ill infants remain in a stable and safe environment. The incubator’s dual temperature monitoring capabilities offer air mode and skin mode ranges from 25.0°C to 37.0°C, allowing healthcare providers to adjust the environment according to the specific needs of each infant.
Equipped with an LCD display, the incubator offers clear visibility of the settings and current conditions inside. Its electrical requirements of ~220V 50Hz or ~230V 60Hz and power consumption of ≤550VA make it energy efficient without compromising performance. The included alarms, such as the high temperature mode alarm (<40.0°C) and the skin mode alarm (±1.0°C), ensure that caregivers are alerted at the first sign of any anomaly, thus safeguarding the infant within.
| Specification | Details |
|---|---|
| Model | YR02187 |
| Display | LCD |
| Electrical Requirement | ~220V 50Hz or ~230V 60Hz |
| Power Consumption | ≤550VA |
| Air Mode Temperature Range | 25.0°C~37.0°С |
| Skin Mode Temperature Range | 25.0°C~37.0°C |
| Air Over Temperature Range | <38.0°C |
| Air Mode High Temperature Range | 37.1°C~39.0°C |
| Skin Mode High Temperature Range | 37.1°C~38.0°C |
| High Temperature Mode Alarm | < 40.0°C |
| Air Mode Alarm | ±3.0°C |
| Skin Mode Alarm | ±1.0°C |
| Skin Sensor Accuracy | ≤±3.0°C |
| Air Control Accuracy | ≤0.5°C |
| Mattress Temperature Uniformity | <0.8°C |
| Humidity Control Range | 30%RH-90%RH |
| O2 Control Range (option) | 20%-60% |
| O2 Display Accuracy (option) | ±3% |
| Electrical Scale Weight Range (option) | 0.1kg-8.0kg |
| Electrical Scale Display Range (option) | ±50g |
| Noise | ≤55dB(A) |
Market Price
The market price for the Infant Incubator YR02187 varies depending on suppliers and additional features requested. In general, the average price range is between $5200 and $6000 USD. This competitive pricing reflects the incubator’s advanced capabilities, ensuring that healthcare facilities receive high value relative to their investment.
Considering the vital role this equipment plays in neonatal care, investing in the YR02187 is not just a transaction but a commitment to offering the best care possible for vulnerable infants. Reach out through Kalstein Plus to obtain an accurate quote tailored to your needs.
Frequently Asked Questions
What are the main benefits of using the Infant Incubator YR02187?
The main benefits include precise environmental control, built-in safety alarms, energy efficiency, and user-friendly operation, all essential for infant care.
Is the oxygen control feature mandatory?
No, the oxygen control feature is optional, allowing healthcare facilities to choose configurations that best meet their specific needs.
Can the incubator’s settings be adjusted remotely?
While specific remote features depend on institution setups, the incubator is generally designed for standard operational use directly by medical staff on-site.
Advantages and Disadvantages
Advantages include its customizable environmental controls, ensuring the right temperature and humidity conditions for the infant’s health. Additionally, its low noise levels promote a tranquil environment necessary for sleep and recovery. The incubator’s portability and user-friendly LCD interface make it convenient for hospital staff.
On the downside, the optional features like the O2 control and electrical scale can contribute to a higher overall cost. Some institutions may also require specific training for optimal use and maintenance.
Product Usage in the Field
The Infant Incubator YR02187 is vital in neonatal intensive care units (NICUs). It supports the care of premature infants by maintaining a controlled environment, assisting them in conserving energy and facilitating growth and recovery. Healthcare professionals can adjust the incubator to meet the unique needs of each infant, leveraging its precision controls.
In practice, the incubator ensures stable temperature, humidity, and oxygen levels, crucial for reducing stress and preventing complications such as hypothermia and respiratory distress. Skilled nurses and neonatologists rely on this equipment to monitor and swiftly respond to the changing needs of infants in their care.
Recommendations
Healthcare facilities should regularly maintain and calibrate the Infant Incubator YR02187 to ensure its accuracy and reliability. Educating the medical staff on correct operation and troubleshooting common issues can improve caregiving efficiency.
For facilities opting for the optional oxygen control feature, it is advisable to monitor its accuracy periodically. Incorporating the incubator into emergency protocols to swiftly secure the environment for neonates during critical situations is also recommended.
If you are seeking a fusion of innovation and quality, you have arrived at the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/infant-incubator-yr02187/.