Product Description
The Infant Bilirubin Phototherapy Unit YR02194 is designed to provide efficient and reliable treatment for neonatal jaundice, a common condition in newborns. This state-of-the-art phototherapy unit utilizes a blue tube light source, which falls within the ideal wavelength range of 400-550nm. This range is highly effective in breaking down bilirubin, the substance responsible for jaundice.
With an impressive effective life of 1000 hours, the YR02194 unit ensures long-lasting performance, reducing the need for frequent maintenance. Moreover, it operates at <150VA input power, making it energy-efficient and cost-effective for medical facilities. The unit boasts an adjustable height range from 1100mm to 1500mm and an adjustable angle of 30°, 60°, and 90°, providing versatility and ease of use in various medical settings.
| Model | YR02194 |
| Input power | <150VA |
| Light source | Blue tube |
| Light source effective life | 1000 hours |
| Wave length | 400-550nm |
| Irradiance treatment distance | 10~500px |
| Effective area | 1125px×600px |
| Infrared radiation in effective area | ≤10mW/cm2(760nm<λ≤1400nm) |
| Ultraviolet radiation in effective area | ≤1.0×10-5mW/cm2 (180nm<λ≤400nm) |
| Operate noise | ≤55dB(A)(ambit noise is lower than 40dB(A)) |
| Basic performance | ≥500μW/cm2 |
| Adjust angle | 30°,60°,90° |
| Adjust height | 1100mm~1500mm |
Market Price
The market price for units like the YR02194 typically ranges from $500 to $800, offering a competitive edge for medical facilities seeking high-performance phototherapy equipment. This price range reflects the advanced features and durability provided by the unit, ensuring an excellent return on investment.
While pricing in this range, the YR02194 offers significant value due to its exceptional specifications that meet stringent clinical requirements, making it an ideal choice for hospitals and clinics focusing on neonatal care.
Frequently Asked Questions
What is the primary application of the YR02194 phototherapy unit?
This unit is specifically designed for treating neonatal jaundice by reducing bilirubin levels in the blood through phototherapy.
What kind of maintenance does the unit require?
The YR02194 unit requires minimal maintenance, primarily involving regular checks of the light source and cleaning the unit to ensure optimal performance.
Is the unit portable for use in different departments?
Yes, the adjustable height and angle facilitate ease of mobility, allowing it to be used across various departments within a healthcare setting.
Advantages and Disadvantages
The YR02194 phototherapy unit boasts numerous advantages, including a durable light source with a life of 1000 hours, energy-efficient operation, and effective treatment coverage. Its versatility in angle and height adjustment enhances its usability across different treatment scenarios, ensuring precise application to the affected area.
However, one potential disadvantage might be the noise level, which is ≤55dB(A). Although this is acceptable within clinical settings, it might be slightly noticeable in extremely quiet environments. Nevertheless, this is a minor setback compared to the unit’s advanced capabilities and effectiveness.
Product Use in the Field
In practical use, the YR02194 phototherapy unit is an indispensable tool in neonatal wards, where it is used to treat infants with jaundice quickly and effectively. Its compact size and adjustability offer flexibility in placement and positioning, ensuring that infants receive the optimal amount of light therapy.
Clinicians appreciate the unit’s straightforward operation and the reliability of its consistent performance, making it an essential asset in neonatal care. Its ability to deliver high irradiance levels over a clearly defined effective area ensures that the treatment is efficient and conforms to clinical protocols.
Recommendations
For optimal use of the YR02194 phototherapy unit, it’s recommended to conduct regular checks on the light intensity and source condition to ensure sustained performance. Periodically cleaning the unit’s surface can also help maintain its durability and performance.
Ensuring proper training for medical staff on adjusting the unit’s height and angle can maximize its effectiveness and safety during use. Additionally, consider requesting a quote or generating one automatically through the Kalstein Plus platform to explore your purchasing options and ensure the best fit for your facility’s needs.
If you’re looking for a fusion of innovation and quality, you’ve arrived at the right place. At Kalstein, we offer you the luxury to explore our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our online purchasing channels, intuitive and agile, are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/infant-bilirubin-phototherapy-unit-yr02194/.