Cutting-Edge Doppler Fetal Monitor YR02180: Technical Excellence in Medical Devices

In the realm of prenatal monitoring, the Doppler Fetal Monitor YR02180 emerges as a superior piece of equipment, engineered to provide meticulous fetal assessment. This device epitomizes technological sophistication combined with user-centric functionality, aimed at enhancing medical outcomes in maternity care. Its ergonomic design and advanced features make it an indispensable tool for obstetricians and health professionals dedicated to fetal health monitoring.

The YR02180 model is celebrated for its high precision and versatility, underpinned by an array of technical specifications that meet rigorous standards. Its ECG capabilities are notable, supporting a 5 Lead Mode including the RA, LA, LL, RL, and V configurations. Moreover, it facilitates connections across various methods such as I, II, III, AVR, AVL, AVF, and V, adjusting effectively to diverse clinical environments.

Product Description

The Doppler Fetal Monitor YR02180 boasts multiple operational modes, contributing to a comprehensive monitoring experience. Its ECG system offers 3 and 5 Lead Modes, ensuring flexibility and adaptability in monitoring critical parameters. Boasting a gain range from x250 to x2000, it maintains an accuracy of ±5% and a resolution of 1 bpm, providing critical insights into fetal cardiac health.

Moreover, its heart rate measuring range between 40~240 bpm and accuracy of ±3bpm ascertain it as a reliable asset in critical care. This monitor exhibits exceptional sensitivity (>200µVp-p) and differential input impedance (≥5MΩ), paving the way for precise ST segment monitoring within a range of -1.0~+1.0mV.

Model YR02180
ECG Lead mode 5 Leads(RA,LA,LL,RL,V)
Connection method I, II, III, AVR, AVL, AVF, V
Lead Mode 3 Leads (RA,LA,LL)
Connection method I, II, III
Gain x250, x500, x1000, x2000
Accuracy ±5%
Resolution 1bpm
Sensitivity >200(uVp-p)
Differential input impedance ≥5MΩ
ST segment Monitoring Range
Measure Range -1.0~+1.0mV
Measure Accuracy -0.8mV~+0.8mV
Heart Rate Measuring range 40~240bpm
Accuracy ±3bpm
Resolution 1bpm
Sensitivity >200UVp-p
Respiration Method Impedance between R-F(RA-LL)
Measuring Impedance Range 0.3~3.0 MΩ
Bandwidth 0.1~2.5Hz
Resp. Rate Adult: 7~120BrPM
Neo/Ped 7~150BrPM
Resolution 1 BrPM
Accuracy ±2 BrPM
NIBP Method Oscillometric
Measuring Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240(Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40~240bpm / 40~150bpm
Alarm Type SYS, DIA, MEAN
Resolution
Pressure 1mmHg
SPO2 Display Number of SPO2, waveform of capacity, Pulse
Measuring range 0~100%
Resolution 1%
Accuracy 70~99% (±2%)
Pulse rate range 0~300bpm
TEMP Channel 2
Measuring and Alarm Range 0~50ºC
Resolution 0.1ºC
Accuracy 0.1ºC
Actualization interval about 1 Second.
Average Time Constant <10 Second.

Market Price

The pricing for Doppler Fetal Monitor models like the YR02180 tends to reflect their technological benefits and their vital role in medical diagnostics. As an investment in advanced medical equipment, market prices for this model typically range between approximately $3,500 and $4,200 USD. This range offers a benchmark for healthcare providers aiming to integrate cutting-edge fetal monitoring tools while ensuring affordability.

Kalstein, a leader in laboratory and medical equipment, assures the highest standard of quality and innovation. Potential buyers seeking detailed pricing can request quotes through the Kalstein website, allowing direct access to current offerings and exclusive deals, ensuring an optimal purchasing experience.

Frequently Asked Questions

What makes the YR02180 unique compared to other fetal monitors in the market?

The YR02180 stands out due to its comprehensive ECG capabilities, high sensitivity, and precise heart rate monitoring, coupled with its user-friendly design.

Is the device compatible with all standard software systems used in hospitals?

Yes, the YR02180 is designed to integrate seamlessly with most standard hospital software systems, supporting efficient data management and patient monitoring.

How many users can operate the device simultaneously?

The device allows for multi-user operability, enabling various health professionals to access and utilize its features as needed for comprehensive care.

Advantages and Disadvantages

Advantages:

  • High precision in monitoring fetal heart rate and other critical parameters.
  • Supports multiple lead modes and connection methods, increasing operational flexibility.
  • Fast data update intervals, crucial for real-time monitoring.

Disadvantages:

  • Initial learning curve due to advanced features, requiring initial training for optimal use.
  • Higher investment cost may be a barrier for smaller medical practices lacking extensive budgets.

Product Usage in the Field

The Doppler Fetal Monitor YR02180 is employed in a variety of clinical settings, ranging from small clinics to large hospital obstetrics departments. Its precision and reliability make it ideal for monitoring fetal health throughout different stages of pregnancy. Whether used during routine check-ups or in critical care scenarios, the YR02180 provides comprehensive insights necessary for proactive prenatal care.

In the field, health professionals utilize the device to detect fetal abnormalities and assess placental health, enabling timely interventions when deviations from normal conditions are detected. The device’s capability to connect and sync with hospital systems enhances patient record management, fostering integrated patient care approaches.

Recommendations

To maximize the lifespan and accuracy of the Doppler Fetal Monitor YR02180, regular maintenance and calibration are essential. Follow the manufacturer’s guidelines for cleaning and storage to ensure the device operates under optimal conditions. Routine training refreshers for clinical staff can also enhance user proficiency and guarantee the best outcomes in fetal monitoring practices.

For practitioners aiming to equip their facility with an advanced fetal monitor, consider the YR02180 for its detailed analysis capabilities. Engage with Kalstein’s innovative platform to request a quote and explore the vast array of medical equipment tailored to meet high standards of medical excellence.

If you’re seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate anymore; we bring science to life, and it’s time to be part of our community. https://kalstein.net/en/product/doppler-fetal-monitor-yr02180/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]