Product Description
The YR05161 ECG Monitoring System is a state-of-the-art device designed to meet the dynamic needs of modern healthcare environments. Equipped with 12 standard conductors, this system ensures precise measurement of cardiac activity, making it indispensable for both hospitals and clinics. Leveraging its broad input dynamic range of ±10Vpp, the YR05161 ensures reliable performance even in high-stakes medical scenarios.
This intelligent system features a minimal patient current leak of <10μA, optimizing patient safety during monitoring. The calibration voltage is standardized at 1mV ± 2% and it maintains tension tolerance of ≥ ± 500mV. With a frequency response of 0.05 ~ 160Hz (-3db) and an impressive noise level of less than 15μVp-p, the device ensures precise readings free from interference.
| Model | YR05161 |
| Guide | 12 standard conductors |
| Input dynamic range | ± 10Vpp |
| Patient current leak | <10μA |
| Calibration Voltage | 1mV ± 2% |
| Tension Tolerance | ≥ ± 500mV |
| Time constant | ≥3.2s |
| Frequency response | 0.05 ~ 160Hz (-3db) |
| Noise level | <15μVp-p |
| Input circuit current | 0.050.05 μA |
| Sensitivity | 2.5, 5.10, 20mm / mV |
| Interchannel interference | ≤0.5mm |
| Paper speed | 6.25,12.5, 25.50mm / s (± 3%) |
| Patient current leak | <10μA |
| AC filter | 50Hz / 60Hz |
| EMG filters | 25Hz / 45Hz |
| Anti-drift filter | 0.15 Hz (adaptive) |
| CMMR | ≥120dB (with AC filter) |
| Sensitivity Valve | ≤20μV |
| Input impedance | ≥50MΩ |
| Work Modes | MAN, AUTO, ANALYSIS modes |
| Acquisition of Potential Customers | 12 bits / 1000 Hz (synchronously 12 leads) |
| Input Circuit | floating; protection circuit against defibrillator effect |
| Screen | 7 inch LCD |
Market Price
The price range for the YR05161 ECG Monitoring System typically lies between 1000 USD and 1800 USD, fluctuating based on factors such as vendor, warranty extensions, and added accessories. This pricing reflects the superior technological integration and quality construction, ensuring longevity and efficiency in healthcare settings. For precise pricing tailored to your needs, we recommend generating an automatic quote via our intuitive Kalstein Plus platform.
Frequently Asked Questions
What makes the YR05161 ECG system stand out from other models?
The YR05161’s distinctive features include its 12 standard conductors, extensive dynamic range, and adaptive anti-drift filter, ensuring accuracy under various conditions.
Is the device easy to operate for someone with basic training?
Yes, the YR05161 is designed with user-friendly controls and can operate in MAN, AUTO, and ANALYSIS modes, making it accessible for all healthcare professionals.
Advantages and Disadvantages
The YR05161 ECG Monitoring System offers numerous advantages, such as a high input impedance of ≥50MΩ, ensuring minimal power loss and enhanced patient safety. Its adaptability across multiple work modes and a floating input circuit with defibrillator protection enhance its functionality in various medical scenarios. Furthermore, its 7-inch LCD makes data visualization straightforward.
However, a potential disadvantage might be the comprehensive nature of features, which could require thorough training for optimal use, particularly in advanced analysis modes. Nonetheless, its advantages significantly outweigh these learning curve issues, particularly in environments requiring high precision and reliability.
Product Use in the Field
The YR05161 is primarily used in hospital and clinic settings for detailed cardiac monitoring. Its ability to capture high-resolution data at 12 bits / 1000 Hz, synchronously across 12 leads, ensures comprehensive cardiac assessment, making it ideal for diagnosing arrhythmias or other cardiac anomalies. Its robust anti-interference capabilities ensure that the device performs reliably in busy electrical environments such as hospitals.
Clinicians can seamlessly integrate the device into existing hospital systems, using wireless modules to enhance patient mobility without compromising data continuity, making it invaluable in both stationary and dynamic monitoring scenarios.
Recommendations
To maximize the lifespan and performance of the YR05161, regular maintenance including calibration checks and software updates is recommended. Proper training for all users, emphasizing the device’s multiple functionalities and modes, will ensure its effective utilization. Additionally, engaging in our Kalstein Plus program can provide users access to timely support and specialized product updates, ensuring the device remains a cutting-edge solution in cardiac monitoring.
If you’re seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with an unparalleled level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/6-channel-smart-hospital-ecg-manufacturing-machine-monitoring-dynamic-holter-ecg-systems-yr05161/.