Product Description
The Benchtop Top Press Lab Freeze Dryer YR05187 from Kalstein is a technological marvel designed for laboratory applications that require precision and reliability. This top-tier freeze dryer offers a compact yet powerful solution with a drying area of 0.08㎡, making it an ideal choice for laboratories where space is at a premium. Its condenser has an impressive capacity of 3-4 L/24h, ensuring efficient operation even during extended use.
Capable of reaching condenser temperatures as low as -55℃, with an option for -80℃, this freeze dryer guarantees optimal conditions for freeze-drying sensitive materials. The equipment achieves a vacuum degree of less than 10 Pa, a testament to its superior performance in achieving rapid and efficient drying processes. With a material tray size of ¢180mm and three layers, the YR05187 offers ample space for processing.
Model | YR05187 |
Freeze drying area | 0.08㎡ |
Condenser capacity | 3-4 L /24h |
Condenser temperature | -55℃ (-80 ℃ optional) |
Vacuum degree | < 10 Pa |
Material tray | ¢180mm, 3 layers |
Bulk capacity | 0.8 L, 10mm thickness |
Vial capacity Φ12mm | 560 pcs |
Vial capacity Φ16mm | 285 pcs |
Vial capacity Φ22mm | 165 pcs |
Style of press | By hand |
Cooling | Air,draughty,ambient temperature ≤25℃ |
Voltage | 220V ,50 Hz; 110V, 50Hz; 110V, 60Hz |
Power | 700W |
Host dimension | 460*625*(370+465) mm |
Host weight | 41 kg |
Market Price
In the market, the Benchtop Top Press Lab Freeze Dryer YR05187 is competitively priced, reflecting its advanced features and robust performance. While the exact cost may vary, potential buyers can expect a price range between approximately 4000 USD and 5000 USD, offering significant value for a piece of equipment that combines innovation with efficiency. For precise pricing, Kalstein offers the opportunity to request a quotation or generate an automatic quote through its Kalstein Plus platform, ensuring transparent and competitive pricing for all customers.
Frequently Asked Questions
What is the primary function of the YR05187 Freeze Dryer?
The YR05187 Freeze Dryer is primarily used for removing moisture from samples by freeze-drying, which preserves the material’s biological and chemical properties.
What is the maintenance requirement for this freeze dryer?
Routine maintenance for the YR05187 includes cleaning the equipment after use, checking and replacing seals regularly, and ensuring the condenser is functioning optimally.
Can the YR05187 handle multiple sample types simultaneously?
Yes, with its multi-layer tray capability, the YR05187 can accommodate multiple samples at once, optimizing time and efficiency in laboratory settings.
Advantages and Disadvantages
One of the most significant advantages of the YR05187 Freeze Dryer is its high efficiency and precision, achieved through its powerful condenser capacity and low-temperature range. This model is ideal for laboratories looking for reliability in extended operations due to its robust build and excellent drying performance. Moreover, its compact design makes it suitable for spaces where laboratory real estate is limited.
However, a potential disadvantage may be the initial setup cost, as advanced laboratory equipment requires a more considerable investment compared to simpler models. Additionally, handling and operation require trained personnel to optimize its functionalities and prevent operational errors.
Field Use
In practical applications, the YR05187 Freeze Dryer is extensively used in pharmaceutical laboratories to preserve biological samples and in the food industry to extend the shelf life of products by removing water content. This equipment excels in environments demanding high precision and where sample integrity must be maintained, offering a reliable solution that performs consistently under demanding conditions.
Its ability to dry various materials, from biological specimens to food products, showcases its versatility across different fields. The ergonomic design and manual press style enhance its usability, allowing operators to tailor the freeze-drying process to specific requirements.
Recommendations
For optimal use and maintenance of the YR05187 Freeze Dryer, it is recommended to operate the machine in a well-ventilated area to facilitate effective cooling and air circulation. Regular calibration checks and adherence to the manufacturer’s maintenance guidelines will extend the equipment’s service life and ensure reliable performance. Users should receive training on the operational procedures to maximize the unit’s efficiency and avoid potential mishaps during the drying process.
The YR05187 Freeze Dryer can be leveraged for a broad range of applications, so it is advisable to align its use with the specific laboratory processes and product requirements. Engaging with Kalstein’s expert support team for additional tips and advice can further enhance your experience and outcomes with the product.
If you are searching for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the most user-friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/benchtop-top-press-lab-freeze-dryer-yr05187/.