The Tabletop Autoclave Class B, models YR03387 to YR03390, is a paramount advancement in sterilization technology, designed to address the comprehensive needs of modern laboratory environments. With its diverse chamber volumes ranging from 8 to 23 liters, this autoclave series is adaptable to various sterilization tasks, catering from small to medium-sized labs. The chamber dimensions and number of trays available provide flexibility in arranging instruments for optimal sterilization efficiency.

Each model presents unique chamber dimensions: YR03387 (Ø170×320 mm), YR03388 (Ø200×360 mm), YR03389 (Ø247×350 mm), and YR03390 (Ø247×450 mm). Depending on the model, users can choose between 2 to 3 trays for the smaller units or upgrade to a maximum of 5 trays with the larger units, providing ample space for instrument arrangement. The material of the trays varies between aluminum and stainless steel, ensuring durability and reliable sterilization cycles. The power specifications accommodate different laboratory settings, operating efficiently at 220/110V and 50/60Hz frequencies.

Model Number YR03387 YR03388 YR03389 YR03390
Chamber Dimension Ø170×320 mm Ø200×360 mm Ø247×350 mm Ø247×450 mm
Chamber Volume 8 L 12 L 18 L 23 L
Number of Trays 2/ Max. 3 2/ Max. 3 3/ Max. 5 3/ Max. 5
Material of Trays Aluminum Stainless Steel Aluminum Aluminum
Size of Trays 130x265mm 156x295mm 192x285mm 192x380mm
Voltage Freq. 220/110V 220/110V 220/110V 220/110V
50/60Hz 50/60Hz 50/60Hz 50/60Hz
POWER.r 2000W 2000W 2000W 2200W
Overall Dimension (WxHxD) 420x370x525 mm 420x370x595 mm 490x455x600 mm 490x455x690 mm
Weight 37 kgs 40 kgs 47 kgs 53 kgs

Market Price

The Tabletop Autoclave Class B is competitively priced in the market, making it an attractive choice for laboratories looking for reliable sterilization solutions. The price range typically falls between $2,200 USD and $3,000 USD, ensuring that you receive a high-quality product without compromising on cost efficiency. It is a prudent investment for your sterilization needs, offering unparalleled performance and reliability.

Frequently Asked Questions

What is the main function of this autoclave?

The primary function of the Tabletop Autoclave Class B is to sterilize medical instruments and laboratory equipment to ensure they are free from any microbial life, including spores and bacteria, through the application of high-pressure steam.

How often should the devices be serviced?

Regular maintenance is crucial for optimal performance. It is generally recommended to service the autoclave every 12 months, depending on usage frequency.

What materials can be sterilized with this autoclave?

This autoclave is suitable for a wide range of materials such as surgical instruments, glassware, and certain types of plastics. However, it’s recommended to check the material compatibility to avoid any damage.

Advantages and Disadvantages

Advantages: The Tabletop Autoclave Class B is celebrated for its user-friendly interface, versatile tray configurations, and efficient sterilization cycles. With a chamber that can accommodate various sizes of instruments and reliable material construction, it provides trustworthy results with each cycle.

Disadvantages: As with any high-technology device, it requires regular maintenance to ensure long-term reliability. Practitioners must also be adequately trained to understand and troubleshoot potential issues.

Use of the Product in the Field

The Tabletop Autoclave Class B is a versatile tool frequently used in hospitals, dental clinics, and research laboratories. It offers efficient sterilization cycles suitable for ensuring the safety of patient-care equipment and laboratory samples. Its adaptability through various tray configurations allows it to accommodate diverse sterilization demands, making it indispensable in environments where sterility is non-negotiable.

Furthermore, its reliable construction and robust sterilization processes make it suitable for ensuring compliance with health regulations and safety standards in medical and research facilities.

Recommendations

To maximize the lifespan and efficiency of the Tabletop Autoclave Class B, it is crucial to follow the manufacturer’s guidelines closely. Ensure that the autoclave is cleaned regularly, and conduct scheduled maintenance checks to avoid potential malfunctions. Using distilled water is recommended to maintain the heating component efficiency and to prevent mineral buildup.

Incorporating a process of routine monitoring and validation of sterilization cycles can significantly optimize outcomes, ensuring the autoclave continues to meet stringent safety and sterility standards.

If you’re seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer; we bring science to life, and it is time to become part of our community. https://kalstein.net/en/product/tabletop-autoclave-class-b-yr03387-yr03390/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]