Product Description
The **YR05128 Microplate ELISA Reader** is a state-of-the-art laboratory instrument designed to deliver high-precision absorbance measurements. It boasts an impressive absorbance range of **0 – 4.000 Abs**, ensuring that it can handle a wide variety of sample types and experimental needs. With a resolution of **0.001 Abs (displayed)** and **0.0001 Abs (calculated)**, the YR05128 Microplate Reader guarantees exceptional accuracy crucial for sensitive assays.
This device is equipped with a **6V/19W halogen lamp** as a light source, known for its efficiency and longevity. The optical system of the device utilizes an **8-channel optical fiber system** which enhances the accuracy and reliability of the readings. Furthermore, the YR05128 features **four standard filters with wavelengths** of **405 nm, 450 nm, 492 nm, and 630 nm**, with the option to add three additional filters to customize your application needs.
| Specification | Details |
|---|---|
| Model | YR05128 |
| Absorbance range | 0 – 4.000Abs |
| Resolution | 0.001 Abs (displayed), 0.0001 Abs (calculated) |
| Light source | 6V/19W halogen lamp |
| Optical system | 8-channel optical fiber system |
| Lengths | 4 standard filters wave: 405 nm, 450 nm, 492 nm, 630 nm, 3 additional optional filters |
| Wavelength accuracy | 2 nm |
| Bandwidth | 8 nm |
| Calculation method | ABS, cut, multipercentage, percentile registry, linear, exponential, index, Regression 4PL, etc. |
| Methodologies | Endpoint, Fixed time, Kinetics |
| Type | Standard microplate with 96 wells or other types of microplate and strip |
| Reading speed | 5 seconds for a 96-well plate (single-wavelength) |
| Memory | Storage for up to 100 programs and 10,000 sample results |
| Printer | Internal thermal printer, optional external printer |
| Dimensions (mm) | 425 (length) x 310 (width) x 215 (height) |
| Weight | 12kg |
Market Price
The price of the YR05128 Microplate ELISA Reader typically falls within the range of **$2500 to $3300 USD**. This cost encompasses the high-level technology and advanced features offered by the product, providing excellent value for money in comparison to other similar products available in the market.
Frequently Asked Questions
What is the reading speed for a 96-well plate?
The YR05128 achieves a reading speed of **5 seconds for a 96-well plate** when using a single-wavelength measurement, maximizing efficiency in laboratory workflows.
Can additional filters be added?
Yes, the device supports up to **three additional optional filters**, allowing customization based on specific laboratory needs.
What types of microplates can be used?
The device is compatible with a standard microplate with **96 wells**, as well as other types of microplate and strip, enhancing its versatility in various applications.
Advantages and Disadvantages
**Advantages** of the YR05128 Microplate ELISA Reader include its high resolution, rapid reading speed, and broad absorbance range. These attributes ensure accuracy and enhance productivity in laboratory settings. Additionally, it features a large memory capacity for storing up to **100 programs** and **10,000 sample results**, which streamlines data management and storage.
**Disadvantages** might include the initial investment required, as the price range may be higher compared to simpler models. Also, users unfamiliar with advanced features might require additional training to fully utilize all functionalities.
Product Use in the Field
The YR05128 Microplate ELISA Reader is predominantly used in clinical laboratories for enzyme-linked immunosorbent assay (ELISA) applications. It plays a pivotal role in the detection and quantification of proteins, hormones, and antibodies, supporting crucial diagnostic processes and research studies.
In research institutions, the device is also employed for kinetic studies, endpoint readings, and fixed time evaluations, offering a broad spectrum of methodological support that can accommodate diverse experimental designs.
Recommendations
To maximize the lifespan and performance of the YR05128 Microplate ELISA Reader, regular maintenance and cleaning are advised. Ensure the halogen lamp is replaced as needed and verify that the filters are dust-free to maintain clear and accurate readings.
It is also recommended to periodically check the device’s calibration and perform routine tests with reference standards. This practice guarantees ongoing precision and reliability of measurement results.
If you’re looking for a blend of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Wait no more, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/microplate-elisa-reader-yr05128/.