Product Description
The BOD Analyzer Model YR06297 stands as a pinnacle of accuracy and reliability in the field of water quality testing. Designed to meet the most stringent standards, this state-of-the-art device offers an expansive test range from 0 to 4000 mg/L. It adheres closely to the accuracy standards required for BOD5 tests, particularly with glucose glutamic acid standard solutions ranging between 180-230 mg/L.
With a test duration flexibility ranging from 1 to 30 days and the capacity to handle up to six samples at a time, this analyzer is optimized for both efficiency and precise long-term assessments. The recording intervals are customizable, spanning from 24 minutes to 12 hours, allowing users to tailor the testing according to specific requirements.
The device boasts a sophisticated storage capability, capable of saving detailed BOD values and biochemical reaction curves for recent tests, alongside maintaining a historical record of up to 20 final data sets. Operating seamlessly at a culture temperature of 20 ±1 °C, it ensures the stability and accuracy of testing conditions.
| Model | YR06297 |
| Test Range | 0-4000 mg/L |
| Test Error | It meets the accuracy testing standard for water quality BOD5 (glucose glutamic acid standard solution BOD5=180-230mg/L) |
| Test Duration | 1-30 days |
| Test Quantity | 6 pieces |
| Recording Interval | 24 minutes -12 hours/time |
| Storage quantity | Detailed data: Save the BOD values and biochemical reaction curves of the latest set of analytical samples. Historical data: Can save 20 sets of final test data. |
| Culture flask solvent | 580ml |
| Culture temperature | 20 ±1 °C |
| Wireless print | |
| Power | 110-220V, 50/60Hz |
Market Price
The BOD Analyzer YR06297 enters the market as a top contender in water quality analysis tools. The pricing for this advanced equipment ranges between 3700 USD to 4500 USD, reflective of its innovative design and comprehensive analytical capabilities. Its sophisticated features justify the premium, positioning it as a valuable investment for laboratories demanding precision and efficiency.
Frequently Asked Questions
What is the maximum sample quantity the BOD Analyzer YR06297 can test simultaneously?
The device is designed to handle up to six samples at a time, making it highly efficient for laboratories with a need for batch testing.
Can the BOD Analyzer YR06297 store historical data for future reference?
Yes, it can save detailed data for the latest samples and up to 20 historical test records, allowing for comprehensive data management and analysis.
Does the device support wireless printing?
Indeed, the BOD Analyzer YR06297 offers wireless print capabilities, enhancing ease of use and integration into existing laboratory workflows.
Advantages and Disadvantages
Advantages: The YR06297 Model provides unparalleled precision in BOD testing, a broad range of test variables, and customizable recording intervals. Its ability to store data extensively is perfect for long-term projects. Additionally, it supports wireless printing, which adds convenience and efficiency by seamlessly streamlining data output processes.
Disadvantages: While offering advanced features, the BOD Analyzer YR06297 requires users to be familiar with its setup and operation, as its sophisticated design might present a learning curve for beginners. Additionally, the upfront cost may be on the higher end compared to simpler devices, though justified by its technological capabilities.
Product Use in the Field
The BOD Analyzer YR06297 is integral in various environmental and industrial applications. It is adept at evaluating the organic pollutant load in water bodies, critical for municipal water treatment facilities and environmental monitoring agencies. This device provides continuous, long-term measurements ensuring compliance with environmental standards.
In practical scenarios, researchers and analysts utilize this equipment to monitor effluent and influent BOD levels, optimizing treatment processes. The device’s real-time data capability also enhances its utility in dynamic testing environments, offering invaluable insights into water quality parameter fluctuations over extended periods.
Recommendations
For optimal use of the BOD Analyzer YR06297, maintain a controlled environment, ensuring consistent temperatures and aeration to prevent external factors from skewing results. Regular calibration checks and software updates are recommended to ensure the device operates at peak efficiency.
Users should explore comprehensive training sessions to become accustomed to the device’s sophisticated functionalities. Leveraging the Kalstein Plus platform for deep insights and automated quotation services can significantly enhance user experience and optimize procurement strategies.
Conclusion: If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/bod-analyzer-yr06297/.