Exploring the Versatility of Pulsating Vacuum Autoclaves

Product Description

The Pulsating Vacuum Autoclave with Printer, covering models YR06418 to YR06423, stands as a cornerstone in modern laboratory sterilization equipment. These autoclaves offer advanced technical features that facilitate superior sterilization through the pulsating vacuum mechanism. This process ensures that steam penetration is deepened, making it ideal for sterilizing complex instruments and porous materials.

One of the main features of these autoclaves is their design pressure of – 0.1/0.3 Mpa and a rated working pressure of 0.23 Mpa, which facilitates optimal sterilization conditions. The maximum working temperature reaches up to 138°C, providing a broad working temperature range from 105°C to 138°C, making it versatile for various sterilization needs. Precision is key in these devices, with a temperature display accuracy of 0.1°C and pressure display accuracy of 0.1 kpa.

The ultimate vacuum rate of – 0.096 Mpa ensures thorough air removal, critical for effective sterilization. Furthermore, the autoclaves offer flexible operational times with sterilization and drying times adjustable between 0 to 99 minutes. Reliable temperature uniformity, maintaining deviations to ≤0.5°C, enhances the consistency of sterilization outcomes.

Model YR06418 YR06419 YR06420 YR06421 YR06422 YR06423
Design pressure – 0.1/0.3 Mpa
Rated working pressure 0.23 Mpa
Max. working temperature 138°C
Working temperature range 105-138°C
Ultimate vacuum rate – 0.096 Mpa
Time for sterilization 0-99 min
Time for drying 0-99 min
Temperature display accuracy 0.1°C
Pressure display accuracy 0.1kpa
Temperature uniformity ≤0.5°C
Power 2.5 KW 3.0 KW 4.5 KW 5.4 KW 7.2 KW 9.3 KW
Size 35L/0316×450 mm 50L/0316×667 mm 80L/0386×695 mm 100L/0386×860 mm 120L/0450×760 mm 150L/0500×780 mm
G.W. / N.W. 110kg/90kg 120kg/100kg 135kg/115kg 140kg/120kg 160kg/140kg 200kg/180kg

Market Price

The Pulsating Vacuum Autoclave with Printer is available in the market with prices typically ranging between $10,400 USD to $11,700 USD. This price range reflects the advanced technology and design quality of the equipment, making it a valuable investment for any laboratory aiming to enhance its sterilization capabilities.

Frequently Asked Questions

What types of materials can be sterilized with this autoclave?

The autoclave is versatile and capable of sterilizing a variety of materials including laboratory instruments, medical devices, textiles, and any equipment that can withstand high temperatures and pressures.

How does the pulsating vacuum function improve sterilization?

The pulsating vacuum function aids in deeper steam penetration. This is particularly beneficial for porous materials and instruments with narrow lumens, ensuring comprehensive sterilization.

Advantages and Disadvantages

Advantages: The Pulsating Vacuum Autoclave offers excellent sterilization capabilities through its precise control systems and advanced vacuum technology. It ensures reliable and consistent sterilization outcomes. With different models offering various power options, it provides flexibility based on the specific needs of different laboratory applications.

Disadvantages: One of the potential downsides could be the initial investment cost, which might be on the higher side compared to basic autoclaves. However, the quality and efficiency offered by these models justify the expense over time. Additionally, it requires training for optimal use, which could necessitate additional resources.

Use of the Product in the Field

The Pulsating Vacuum Autoclave is extensively used in hospital sterilization units and research laboratories. Its ability to handle complex and critical sterilization tasks makes it indispensable in these environments. By ensuring that all microbial life is eliminated from reusable medical devices, it supports compliance with health and safety standards, thereby enhancing patient and staff safety.

In laboratory settings, the autoclave is crucial in preparing media and decontaminating waste efficiently. Its diverse range of applications makes it a versatile tool in both industrial and academic research settings.

Recommendations

To maximize the efficiency and lifespan of the Pulsating Vacuum Autoclave, regular maintenance checks are crucial. Ensure that operators are well-trained in using the equipment, focusing on the correct loading techniques to optimize steam penetration and avoid damage to delicate items. Routine calibration of temperature and pressure controls is recommended to maintain accuracy and precision over time.

Consider investing in compatible accessories and consumables, which can enhance the versatility and ease of use of the autoclave. Working closely with the supplier to understand the full capabilities and limits of the autoclave will drive better utilization and satisfaction from the product.

If you are seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a distinguished level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most affordable prices. Don’t hesitate anymore, we bring science to life; it’s time to become part of our community. https://kalstein.net/en/product/pulsating-vacuum-autoclave-with-printer-yr06418-yr06423/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]