Product Description
The 4.3-Inch LCD Infusion Pump represents a fusion of precision engineering and cutting-edge technology. Designed to meet the rigorous demands of medical settings, this infusion pump boasts a range of features that ensure accuracy and reliability. It employs a drip type infusion mechanism with peristaltic fingers, offering an adjustable drip rate of 1 to 400 drops per minute, and a volume rate of 1 to 1200 ml per hour. This variability allows health professionals to fine-tune the delivery rates to match patient needs with precision.
With a flow accuracy of within 3% and mechanical precision within 2%, this infusion pump guarantees consistency in every drop, crucial for patient safety. The purge rate is a robust 800 ml per hour, while the KVO (Keep Vein Open) rate adjusts from 1 ml/hour to 3 ml/hour depending on the flow, ensuring continuous operation. The infusion volume range extends from 1 ml to 9999.9 ml, with a maximum accumulated volume of 9999.9 ml, offering flexibility for various medical applications.
Pump type | Drip Type Infusion Pump | ||
Pumping Form | Peristaltic fingers | ||
Adjustable Fall Rate Range | 1 ~ 400 drops / min (step: 1 drop / min) | ||
Adjustable Volume Rate Range | 1 ~ 1200 ml / h (when 1 ~ 99.9 ml / h, step: 0.1 ml / h; greater than 99.9 ml / h, step: 1 ml / h) | ||
Flow Accuracy | Within 3% or so (using manufacturer’s designated IV kit or high quality calibrated IV kit) | ||
Mechanical precision | Within 2% or so | ||
Purge Rate | 800ml / h | ||
KVO rate | 1 ml / hour (1 ~ 300 ml / hour) | ||
3 ml / h (more than 300 ml / h) | |||
Infusion Volume Range | 1 ml ~ 9999.9 ml (step: 0.1 ml) | ||
Maximum Accumulated Volume | 9999.9 ml (step: 0.1 ml) | ||
Time interval | 1 min ~ 9999 min (step: 1 min) | ||
Occlusion Alarm Threshold | Height: 800 mmHg + -200 mmHg (106.7 kPa + -26.7 kPa) | ||
Medium: 500 mmHg + -100 mmHg (66.7 kPa + -13.3 kPa) | |||
Low: 300 mmHg + -100 mmHg (40.7 kPa + -13.3 kPa) | |||
Alarm | Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle. | ||
Air Bubble Detector Method | Ultrasonic wave, sensitivity: greater than or equal | ||
25 l | |||
Fuse | F1AL / 250V (“F” indicates fast, “L” indicates low breaking power), 2 pieces (installed inside the pump). | ||
Power supply | AC 85 ~ 265V, 50 / 60Hz; | ||
Internal Battery | 11.1V rechargeable lithium-ion battery. Capacity: greater than or equal to 2000 mAh; | ||
The pump can run more than 4 hours at a flow rate of 25ml / h after charging for 8 hours (average flow rate specified by GB 9706.27-2005). | |||
Energy | Less than or equal to 40VA | ||
Size | 188mm (length) x 198mm (width) x 228mm (height) | ||
Weight | 2.2 kg | ||
Environmental requirements | Transport | ||
Ambient temperature: -30 ° C ~ + 55 ° C | |||
Relative humidity: 20% ~ 95% (non-condensing) | |||
Atmospheric pressure: 70kPa ~ 106kPa | |||
Storage | |||
Ambient temperature: -30 ° C ~ + 55 ° C | |||
Relative humidity: 20% ~ 95% | |||
Atmospheric pressure: 70kPa ~ 106kPa | |||
Operation | |||
Ambient temperature: + 5 ~ + 40 ° C | |||
Relative humidity: 20% ~ 90% | |||
Atmospheric pressure: 86kPa ~ 106kPas | |||
Calibration function | Disposable IV set of any brand is suitable for this pump | ||
Three Working Modes | Rate / volume / time mode | ||
Alarm | Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle. |
Market Price
In the competitive market of medical equipment, the infusion pump with a 4.3-inch LCD screen is generally priced between 500 USD and 800 USD. This price range reflects the premium features and technological advancements that come with this device. Considering its sophisticated capabilities and the importance of precision in medical applications, this pricing is highly competitive within its category.
Frequently Asked Questions
How does the infusion pump detect air bubbles?
The infusion pump utilizes ultrasonic wave technology for detecting air bubbles, ensuring operational safety and reliability.
Can the pump work with any brand of IV set?
Yes, the pump is versatile and can be calibrated to work with a disposable IV set of any brand, ensuring ease of integration into existing setups.
What happens if the power goes out?
The infusion pump is equipped with an internal rechargeable lithium-ion battery, which allows it to continue operating for more than 4 hours at a flow rate of 25 ml/h after being fully charged.
Advantages and Disadvantages
Advantages: The infusion pump offers unparalleled precision with flow accuracy within 3%, a critical factor in medical treatments. The extensive alarm systems, including occlusion, air bubbles, and low battery warnings, provide peace of mind and enhance safety. Its compatibility with various IV sets and adjustable settings further make it a versatile tool in clinical settings.
Disadvantages: While the device is feature-rich, its complexity might require comprehensive training for optimal use. Additionally, the initial investment, although justified by its functionality, might be a consideration for budget-constrained institutions.
Field Usage of the Product
The infusion pump is mainly utilized in hospitals and medical clinics where precise medication delivery is essential. It is particularly useful in intensive care units and surgeries where maintaining exact fluid volumes can significantly impact patient outcomes. The device’s capability to adjust flow rates and alarm thresholds easily makes it an invaluable tool for critical patient care. Furthermore, its lightweight design and battery operation ensure that it can be used in various settings, including ambulatory care or during patient transport.
Clinicians appreciate the infusion pump’s user-friendly interface, facilitated by the clear and large 4.3-inch LCD screen, which eases monitoring and adjustment in real-time, thus improving efficiency and reducing the likelihood of errors.
Recommendations
To maximize the lifespan and functionality of the infusion pump, regular maintenance and calibration are recommended. It’s crucial to keep the device clean and ensure the IV sets are compatible according to the manufacturer’s recommendations. Training staff to understand the various alarm settings and troubleshooting procedures will enhance device efficacy and safety.
This infusion pump is ideal for facilities aiming to improve patient care through technology. We invite you to explore the Kalstein Plus platform for an automated quote, a step that brings you closer to integrating this sophisticated equipment into your practice.
If you are in search of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most user-friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/4-3-inch-large-lcd-screen-remote-control-infusion-suction-pump-yr05164/.