Product Description
The Dual-Person Laminar Flow Cabinet, models YR05268-1 and YR05269-1, is at the forefront of laboratory safety and efficiency. Engineered to provide a contamination-free environment, this cabinet adheres to the ISO 14644.1 standard, guaranteeing a CLASS 5 cleanliness rating equivalent to the U.S. Federal 209E, 100 Level. This ensures an ultra-clean atmosphere, perfect for handling sensitive experiments and materials.
Equipped with an adjustable wind speed ranging from 0.3 to 0.6 m/s, the cabinet provides flexibility to meet different operational requirements. Its noise level is maintained at ≤62 dB, promoting a quiet laboratory environment. Vibration is minimized to a half peak of ≤3μm in the X, Y, and Z directions, ensuring stability for delicate procedures.
The cabinet integrates a high-efficiency filter with a filtration rate of 99.99%, coupled with illumination levels that meet or exceed 300 LX. This combination allows for a highly effective workspace that enhances visibility and precision. Additionally, the cabinet is tailored for an ambient temperature range of 10~30℃ and a relative humidity below 70%, ensuring optimal conditions with no significant vibration or dust interference.
The device dimensions are ergonomic, with an external size of 1585×1460×735 mm and an internal workspace of 500×1300×680 mm. It operates at an AC voltage of 220V/50Hz and consumes 870W of power, reflecting its energy-efficient design. The cabinet’s robust construction supports a net weight of 210 kg, while its shipping weight is 235 kg, with a packing size of 1030×1650×855 mm.
Model | YR05268-1 / YR05269-1 |
Cleanliness Rating | The international ISO 14644.1 standard, CLASS 5 (U.S. Federal 209E, 100 level) |
Wind Speed | 0.3~0.6m/s(Adjustable) |
Noise (dB) | ≤62 |
Vibration Half Peak | ≤3μm(X、Y、Z direction) |
High Efficiency Filter | Efficiency 99.99% |
Illumination(LX) | ≥300 |
Work Environment | Ambient temperature 10~30℃, Relative humidity |
below 70%, No obvious vibration and dust around | |
Overall size(mm)(H×W×D) | 1585×1460×735 |
Inner size(mm) (H×W×D) | 500×1300×680 |
Voltage(V)/ | AC220V/50Hz |
Power(W) | 870 |
Net weight (KG) | 210 |
Shipping weight(KG) | 235 |
Packing size(mm)(H×W×D) | 1030×1650×855 |
Market Price
The market for laminar flow cabinets is competitive and diverse. For the Dual-Person Laminar Flow Cabinet, the price typically ranges between $3,600 to $4,400 USD. This range reflects variations in features, shipping, and customization options that might accompany different sale offers. Investing within this range ensures access to a high-quality product with a comprehensive value proposition.
Frequently Asked Questions
What maintenance is required for the laminar flow cabinet?
Regular maintenance includes checking filter efficiency, ensuring no obstructions in airflow, and periodic cleaning of the unit’s surfaces and filters to prevent contamination.
How often should the filters be replaced?
The filters should be assessed regularly and replaced depending on usage intensity, typically every 12 to 18 months, or as soon as performance diminishes.
Can the cabinet operate in non-standard environments?
The cabinet is designed for a specific temperature and humidity range. Operating outside these limits is not recommended as it can affect performance and filter lifespan.
Advantages and Disadvantages
One of the primary advantages of the Dual-Person Laminar Flow Cabinet is its capability to create a standardized clean environment, pivotal for laboratories conducting sensitive research. The high-efficiency filter, adjustable wind speed, and low noise operation enhance laboratory productivity and comfort.
However, a disadvantage might involve its significant initial investment compared to simpler, non-laminar systems, although this is offset by its long-term utility and durability. The requirement for regular maintenance could also be seen as a deterrent for laboratories with limited resources.
Product Use in the Field
In practical applications, the Dual-Person Laminar Flow Cabinet is essential for tasks demanding stringent contamination control, such as in microbiology or pharmaceutical preparations. Its dual-user capability permits collaborative work, promoting team productivity in detailed experiments.
The cabinet is built to support critical applications, ensuring materials handled within its confines remain free from airborne contaminants, thus upholding research integrity and safety standards.
Recommendations
To maximize the benefits of the Dual-Person Laminar Flow Cabinet, it is advised to place it in a stable, vibration-free location within the lab. Frequent employee training on operational best practices can significantly enhance its efficacy and prolong its functional life.
Ensure a regular maintenance schedule to check and replace filters to maintain optimal performance. It is also beneficial to integrate its use within standard operating procedures to maintain consistency in lab processes.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life; it is time to become part of our community. https://kalstein.net/en/product/laminar-flow-cabinet-double-person-yr05269-yr05269-1/.