Precision and Innovation: Key Features of the YR05482 Benchtop Spectrophotometer

Product Description

The YR05482 non-contact benchtop spectrophotometer is engineered for precision in color measurement across a variety of sample forms, including liquids, powders, and sauces. Designed to meet standards such as CIE No.15, GB/T 3978, and ISO7724-1, this spectrophotometer delivers reliable and accurate color analysis, essential for quality control in industries ranging from cosmetics to food hygiene.

This state-of-the-art spectrophotometer features a 45/0 method illumination system with a full spectrum LED and UV light source, ensuring detailed and accurate readings. A concave grating spectrophotometric mode is used to capture data, analyzed by a 256 Image Element Double Array CMOS Image Sensor. The device covers a wavelength range of 400-700 nm and offers a reflectance range from 0 to 200%.

Designed for versatility, the YR05482 has a measuring aperture of 20 mm, with customizable options available, maintaining a non-contact measuring distance of 7.5 mm. It supports various color spaces, including CIE LAB, XYZ, and HunterLAB, and provides multiple color difference formulas such as ΔE*ab and ΔE*cmc. With a large data storage capability and repeatability within ΔE*ab 0.03, this spectrophotometer is both efficient and robust.

Model YR05482
Illumination system 45/0 method(45 ring-shaped illumination, vertical viewing); Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7
Features 45/0 non-contact benchtop spectrophotometer that achieves precise non-contact measurement for samples like liquids, powders, etc. Useful in laboratories and R&D industries.
Light Source Full spectrum LED light, UV light
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 400~700nm/10nm output
Reflectance Range 0~200%
Measuring Aperture Φ20mm(can be customized <20mm)
Non-contact Distance 7.5mm
Sample Height 0~150mm
Distance Adjustment Method Manual and automatic adjustment, test height can be stored
Measuring mode Sample mode/QC Mode/Continuous statistics mode
Locating Method Camera Locating
Color Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, HunterLAB
Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, ΔE(Hunter)
Observer Angle 2°/10°
Illuminant D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30)
Displayed Data Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, Chromaticity Graph, Color Simulation, PASS/FAIL Result, Color Offset
Measuring Time About 1.5s
Data Storage Sample mode + QC mode: 40,000; Continuous statistics mode: 10,000
Repeatability Spectral reflectance: Standard deviation within 0.08%; Chromaticity value: Within ΔE*ab 0.03
Inter-instrument Error Within ΔE*ab 0.2(Average for 12 BCRA Series II color tiles)
Measurement Mode Single Measurement, Average Measurement(2 ~ 99 times)
Dimension 330*250*370mm
Weight About 10 kg
Power Supply DC 24V, 3A Power Adapter
Illuminant Life Span 5 years, more than 3 million times measurements
Display Screen 7″ TFT Capacitive Screen-touch Display
Data Port USB/RS-232, Bluetooth®4.0
Language Simplified Chinese, Traditional Chinese, English
Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation); Altitude < 2000m
Storage Environment Temperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard Accessory Power Adapter, User Manual, USB cable, Standard Calibration Board, Black Calibration Cavity
Notes The specifications are subject to change without notice.

Market Price

In the competitive market of laboratory equipment, the YR05482 non-contact benchtop spectrophotometer is priced within the range of USD 10,500 to USD 11,800. This range reflects the superior technology and the precise measurements this equipment offers, making it a wise investment for laboratories and research facilities focused on maintaining high standards of quality control.

Frequently Asked Questions

What types of samples can be measured with the YR05482 spectrophotometer?

The YR05482 is capable of measuring liquids, powders, sauces, and various other non-contact sample forms, providing versatility for different industries.

How often should the device be calibrated?

For optimal performance, it is recommended to calibrate the spectrophotometer regularly, as per the standard operating procedures provided in the user manual.

Can this device be integrated into an automated production line?

Yes, the YR05482 is designed to be integrated into automated production lines for stringent quality control, making it suitable for industrial applications.

What are the data storage capabilities of this spectrophotometer?

This model offers a significant storage capability, accommodating up to 40,000 samples in Sample and QC modes, and 10,000 in continuous statistics mode.

Advantages and Disadvantages

Advantages: The main advantages of the YR05482 include its non-contact measurement, which prevents contamination and damage to samples, and its rapid measurement time of approximately 1.5 seconds per sample. It also supports a wide range of color space and illuminant options, facilitating comprehensive color analysis.

Disadvantages: A potential downside could be its substantial size and weight, which might limit portability or require dedicated space on a lab bench. Additionally, the sophisticated features may necessitate specialized training for new users to leverage its full capabilities.

Product Usage in the Field

In practical applications, the YR05482 spectrophotometer is utilized in settings ranging from cosmetic research labs to food safety testing facilities. It plays a crucial role in ensuring the accurate color matching of products, vital for maintaining brand consistency in cosmetics. In the food industry, it aids in verifying the quality and safety of products by providing precise color readings that indicate freshness or contamination.

The spectrophotometer’s ability to function within a wide temperature and humidity range also ensures that it delivers reliable results under various environmental conditions, thereby supporting diverse industrial needs.

Recommendations

To maximize the efficacy and longevity of the YR05482 spectrophotometer, it is recommended to regularly follow the maintenance schedule as outlined in the user manual. This includes timely calibration, software updates, and general cleanliness of the equipment.

Ensure that users are adequately trained in the operation of the device to fully exploit its capabilities. For industries that depend heavily on precise color readings, integrating the device with existing quality control protocols may yield significant improvements in product consistency and safety.

Utilizing the intuitive interface and the Kalstein Plus platform can enhance your purchasing experience, offering seamless quotes and purchase processes directly from the provider.

If you’re seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each equipment with a high level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. Learn more about the YR05482 here.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]