Product Description
The YR55-3 Water Purification System represents a significant advancement in water purification technology, designed to meet the critical demands of laboratory environments. Engineered with precision, this system transforms urban tap water into high-quality laboratory-grade water, suitable for a wide range of scientific applications. The YR55-3 model stands out for its efficiency and reliability, ensuring constant delivery of purified water with consistent quality.
This system is powered by a robust multi-stage purification process, which includes reverse osmosis (RO) and ultrapure (UP) water production capabilities. It features an impressive water flow speed of 1.5-2L/min and a machine capacity of 15L/H. The YR55-3 is particularly remarkable for producing RO water with a conductivity level of 1-5 μS/cm, aligned with ASTM type III standards, and UP water with a resistivity of 18.25MΩ.cm @ 25°C, meeting ASTM type I standards. With such advanced specifications, this system effectively minimizes contaminants, delivering high-purity water that has a Total Organic Carbon (TOC) content of less than 3 ppb.
Model | YR55 | YR55-1 | YR55-2 | YR55-3 |
Inlet water source | Urban tap water, inlet water pressure: 0.15-0.5MPa, water temperature 5-40°C | |||
Water flow speed | 1.5-2L/min ( with pressure barrel) | |||
Machine capacity | 15 L/H | 15 L/H | 15 L/H | 15 L/H |
Output Water quality |
RO water: Conductivity 1-5 μS/cm (ASTM type III water) | |||
UP water: resistivity 18.25MΩ.cm@25°C (ASTM type I water) TOC: <3 ppb, particles (>0.22 um) <1/ml, microorganism <1 cfu/ml |
||||
Total organic carbon (TOC) | <10 ppb | <3 ppb | ||
Pyrogen (endotoxin) | N/A | < 0.001 Eu/ml | N/A | < 0.001 Eu/ml |
Ribonuclease (RNases) | N/A | <1pg/ml | N/A | <1pg/ml |
Deoxyribonucleases | N/A | <5pg/ml | N/A | <5pg/ml |
Market Price
The average market price for high-quality water purification systems similar to the YR55-3 typically ranges between $8,000 and $8,800. This price range reflects the system’s sophisticated technology and its ability to deliver reliable high-purity water under diverse laboratory conditions. When investing in the YR55-3, laboratories benefit from both its durability and advanced features.
Frequently Asked Questions
How does the YR55-3 achieve high purity in water output?
The YR55-3 uses reverse osmosis and deionization technologies to remove contaminants, achieving a low TOC content and high water resistivity, essential for lab-grade applications.
What is the maintenance routine for the YR55-3?
Maintenance involves regular filter changes and performance checks, typically scheduled based on usage and water quality input.
Can the YR55-3 handle varying water temperatures?
Yes, the YR55-3 effectively processes water with temperatures ranging from 5°C to 40°C, making it adaptable to variable source conditions.
Advantages and Disadvantages
Advantages: The YR55-3 offers multiple benefits such as high efficiency, robust purification technology, and excellent water quality outputs exceeding ASTM standards. It is engineered for long-term reliability and low TOC levels, making it highly suitable for precision-dependent laboratory environments.
Disadvantages: One potential downside is the cost of maintenance, as regular checks and periodic components replacement like filters can add to operational expenses. However, these ensure the purity and reliability of the system’s output.
Product Usage in the Field
In practical laboratory applications, the YR55-3 is indispensable for processes requiring consistent high purity water, such as analytical experiments, preparation of reagents, and microbial cultivation. Its reliable performance helps ensure accurate results in sensitive laboratory analyses, thereby supporting critical scientific and medical research.
To fully leverage its capabilities, many labs integrate it into their workflows for applications such as tissue culture and molecular biology. Its high resistivity and low levels of endotoxins make it ideal for environments where contamination must be minimized at all costs.
Recommendations
For optimal performance, it is recommended to monitor the inlet water quality regularly, ensuring the system operates within its specified parameters. Establish a routine maintenance schedule to include filter replacements and system inspections. For any issues encountered, consult the manufacturer’s guidelines or contact their support team for expert assistance.
Are you interested in bringing the benefits of this advanced purification system to your lab? Visit our Kalstein Plus platform to request a quotation or generate an automatic quote today. By choosing Kalstein, not only do you secure state-of-the-art equipment, but you also join a community committed to excellence in the scientific domain.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it is time to be part of our community. https://kalstein.net/en/product/water-purification-system-yr55-yr55-3/.