Product Description
The Horizontal Pulsating Vacuum Autoclave with an automatic vertical sliding door offers cutting-edge technology combined with advanced sterilization capabilities. This autoclave is meticulously designed to cater to laboratories demanding precision and efficiency. Available in models ranging from YR05647 to YR05650-1, this equipment ensures a tailored fit for different sterilization capacities, varying from 150 L to 360 L. The device operates under a design pressure of -0.1/0.3Mpa and a design temperature of 150℃, making it robust and reliable for numerous applications.
Equipped with a working temperature range of 105℃-139℃ and a working pressure range of 0-0.25Mpa, the autoclave guarantees optimal sterilization results. The precise temperature control accuracy of ≤ ± 0.2℃ and a display accuracy of 0.1℃ ensure stringent monitoring and control. Furthermore, its sterilization time and drying time range from 0 to 999 minutes, allowing for flexibility according to different requirements.
For ease of use, the autoclave features a PLC + HMI + Printer control system and a 7.0-inch color touch screen for intuitive operation. Safety is prioritized with a safety valve pressure of 0.28Mpa and a vacuum rate of -97Kpa, ensuring secure operation even under demanding conditions. Additional features include a built-in printer, water tank, water pump, and steam generator, emphasizing its comprehensive utility in laboratory settings.
This Class B front-loading fully automatic horizontal autoclave is available with single or double door options, making it adaptable to various laboratory setups and space constraints. The models offer diverse dimensions, such as 450*450*750 for smaller capacities and 610*610*1000 for larger volumes, making it an ideal choice for laboratories with specific spatial requirements.
| Model | YR05647 | YR05647-1 | YR05648 | YR05648-1 | YR05649 | YR05649-1 | YR05650 | YR05650-1 |
| Design pressure | -0.1/0.3Mpa | |||||||
| Design temperature | 150℃ | |||||||
| Working temperature range | 105℃-139℃ | |||||||
| Working pressure range | 0-0.25Mpa | |||||||
| Temperature control accuracy | ≤ ± 0.2℃ | |||||||
| Temperature display accuracy | 0.1℃ | |||||||
| Sterilization time range | 0-999min | |||||||
| Drying time range | 0-999min | |||||||
| Vacuum rate | -97Kpa | |||||||
| Temperature equilibrium | ≤±0.5℃ | |||||||
| Safety valve open pressure | 0.28Mpa | |||||||
| Water source | 0.15-0.3MPa | |||||||
| Steam pressure | 0.2-0.6Mpa | |||||||
| Compressed air source | 0.4MPa-0.7MPa | |||||||
| Door Number | Single Door | Double Door | Single Door | Double Door | Single Door | Double Door | Single Door | Double Door |
| Sterilization capacity | 150 L | 200 L | 250 L | 360 L | ||||
| Size | 450*450*750 | 550*550*700 | 550*550*850 | 610*610*1000 | ||||
| Type | Front loading fully automatic horizontal autoclave | |||||||
| Class | Class B | |||||||
| Door type | Automatic vertical sliding door | |||||||
| Control | PLC + HMI + Printer | |||||||
| Display | 7.0 inch color touch screen | |||||||
| Additional Features | Built-in printer Warranty: 2 years Language: English, Spanish, Chinese Built-in water tank Built-in water pump Built-in steam generator |
|||||||
Market Price
In the competitive market of laboratory equipment, the Horizontal Pulsating Vacuum Autoclave stands out not only for its advanced features but also for its cost-efficiency. The average market price for this model ranges between $28,000 and $28,800 USD. While the initial investment is considerable, the value delivered through its long-term reliability and performance justifies the expense. Organizations looking to enhance their sterilization processes will find this product to be an excellent addition to their laboratory infrastructure.
Frequently Asked Questions
What capacity options are available for these autoclaves?
The autoclaves come in different models with capacities ranging from 150 L to 360 L, catering to diverse laboratory needs.
Is this autoclave suitable for high-temperature sterilization?
Yes, it is designed to function effectively at high temperatures, with a working range from 105℃ to 139℃, ensuring thorough sterilization.
How is the user interface designed?
The autoclave features an intuitive 7.0-inch color touch screen for ease of operation, along with a PLC + HMI + Printer system for comprehensive control and documentation.
Advantages and Disadvantages
The Horizontal Pulsating Vacuum Autoclave offers multiple advantages, including its high precision in temperature control, flexibility in sterilization and drying times, and robust construction ensuring durability and high performance. The built-in water tank, pump, and steam generator add an extra layer of convenience, particularly in facilities with limited access to these resources.
However, one must consider the initial cost and space requirements, as the installation of such advanced equipment necessitates adequate planning. Nonetheless, for laboratories with the need for precise and reliable sterilization capabilities, the benefits outweigh these initial challenges, making it a favorable investment.
Product Use in the Field
In real-world scenarios, the Horizontal Pulsating Vacuum Autoclave proves essential for sterilizing instruments, media, and laboratory tools necessary for scientific research and medical applications. Its precision and functionality reduce the risk of contamination, contributing significantly to maintaining high laboratory standards. The autoclave is particularly useful in environments requiring sterile procedures, such as microbiology labs, pharmaceutical industries, and clinical settings.
The equipment’s user-friendly interface and programmability enable operators to customize cycles based on specific needs, providing flexibility across different sterilization tasks. Its robust design ensures that it withstands rigorous use, thereby offering long-term service.
Recommendations
To maximize the effectiveness and longevity of the Horizontal Pulsating Vacuum Autoclave, regular maintenance is crucial. It is advisable to follow manufacturer guidelines for cleaning and servicing to ensure consistent performance. Staff should be adequately trained to operate the autoclave efficiently, ensuring that its advanced features are leveraged entirely.
Additionally, investing in a reliable water source and ensuring that the appropriate power supply levels are maintained will enhance the autoclave’s operational efficiency. By understanding and adhering to these operational protocols, users can ensure optimal performance and achieve desirable results in sterilization tasks.
If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a level of excellence. Our online purchase channels, intuitive and agile, are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life; it is time to become part of our community. https://kalstein.net/en/product/horizontal-pulsating-vacuum-autoclave-automatic-vertical-sliding-door-yr05647-yr05650-1/.