Innovative Capabilities of the YR05731 Horizontal Air Supply Clean Bench

Product Description

The YR05731 Horizontal Air Supply Clean Bench is a specialized piece of laboratory equipment designed to provide a contamination-free workspace by directing a horizontal flow of filtered air. This model guarantees a cleanliness level of Class 100@≥0.5μM (US Federal 209E), making it ideal for applications requiring stringent contamination control. It achieves this by maintaining a low number of colonies, ≤0.5pcs/dish·hour, on a Φ90mm culture plate, ensuring sample integrity in its operational environment.

The product is engineered to create a stable, uniform airflow across the work surface with an average wind speed ranging from 0.25 to 0.45 m/s. Its operational noise level is kept at a minimum, ≤62dB(A), allowing for a quiet work environment, while the vibration half peak is limited to ≤5μM across all directions (x, y, z). These features collectively ensure precise and sensitive laboratory procedures can be performed with ease.

Model YR05731
Cleanliness Level Class 100@≥0.5μM (US Federal 209E)
Number of Colonies ≤0.5pcs/dish·hour (Φ90mm culture plate)
Average Wind Speed 0.25~0.45m/s
Noise ≤62dB(A)
Vibration Half Peak ≤5μM(x、y、z direction)
Illuminance ≥300Lx
Power Supply AC single phase 220V/50Hz
Maximum power 640W
Weight 160kg
Work area size
W1×D1×H1
1770×510×600
1800×740×1440
Dimensions Double single
High efficiency filter specification and quantity 1700×560×50
Specification and quantity of fluorescent lamp/ultraviolet lamp 20W×1
36W×1

Market Price

The Horizontal Air Supply Clean Bench YR05731 is positioned in the market with a price averaging between 2300 USD and 3000 USD. This range reflects the advanced capabilities and high performance level it offers to laboratories and facilities concerned with sterility and precision. Investing in this equipment will ensure a return through enhanced laboratory standards and process reliability.

Frequently Asked Questions

What is the primary use of the YR05731 Clean Bench?

The YR05731 Clean Bench is primarily used for providing a contamination-free environment by utilizing horizontal airflow through HEPA filters, which is critical for laboratory applications that require clean air for sensitive procedures.

How does the YR05731 control contamination?

Contamination is controlled using high-efficiency particulate air (HEPA) filters that remove pariculate contaminants from the air passing through it, achieving Class 100 cleanliness levels.

Is there any special maintenance required?

Routine maintenance involves periodic checks and replacements of HEPA filters as per usage frequency and environment specifications. Regular cleaning of the work surface and outer structure is also recommended.

Advantages and Disadvantages

Advantages: The YR05731 horizontal air supply clean bench affords laboratories with outstanding air cleanliness levels, ensuring sample integrity and enhancing procedural accuracy. Its low noise and vibration features promote a focused work environment, which is vital for precision-driven tasks.

Disadvantages: While offering advanced features, the YR05731 demands significant initial investment, making it more suited for facilities requiring high-efficiency contamination control. It also requires periodic maintenance to sustain performance levels.

Use of the Product in the Field

The YR05731 Clean Bench is widely used across various laboratory settings including microbiology, electronics, and pharmaceuticals, where maintaining a contamination-free environment is critical. It facilitates tasks such as sample preparation, testing, and assembly of delicate electronic components by ensuring a constant flow of clean air, thus preventing contamination during open work processes.

In the pharmaceutical industry, it serves as an invaluable tool in preventing cross-contamination during drug formulation and testing, while in hospitals, it aids in performing aseptic operations or preparing sterile antibiograms.

Recommendations

To maximize the utility and longevity of the YR05731 Clean Bench, it is crucial to follow a regular maintenance schedule, including timely replacement of filter systems. It is also advisable to ensure that the placement of the bench complements airflow patterns for optimal performance. Users should always adhere to operational guidelines and training to fully exploit its advanced features.

If you are searching for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalogue of laboratory equipment. We manufacture each piece with a standard of excellence unmatched in the industry. Our online purchasing channels are intuitive and swift, crafted for your convenience, ensuring the most favorable prices. Don’t hesitate any longer, we bring science to life, it’s time you became part of our community. https://kalstein.net/en/product/horizontal-air-supply-clean-bench-yr05731/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]