Product Description
The Digital Clinical Refractometer series, cataloged under models YR05966 to YR05968, represents a significant leap in diagnostic instruments, tailored for diverse scientific needs. Designed with precision in mind, these refractometers cater to a wide array of applications, whether estimating urine specific gravity, serum protein concentrations, or refractive index in laboratory samples. More specifically, the YR05966 model facilitates accurate measurements of urine specific gravity, boasting a range from 1.000 to 1.050 with an impressive accuracy of ±0.002 and minimal division of 0.001.
Meanwhile, the YR05967 variant is adept at measuring serum protein levels, working within a spectrum of 0 to 12.1 g/dl and precision of ±0.2. Its minimal division is 0.1, enhancing the clarity and reliability of readings. The YR05968 model completes the trio as a reliable tool for determining refractive index values from 1.3330 to 1.3900nD with an accuracy of ±0.0003nD. Noteworthy is the automatic temperature compensation (ATC) feature across all models, operating seamlessly within 0-40°C, ensuring that readings remain unaffected by external temperature fluctuations.
| Model | Description | Measurement Range | Min. Div. | Accuracy | ATC | ATC Temp. |
| YR05966 | URINE SP. G. | 1.000-1.050 | 0.001 | ±0.002 | Yes | 0-40°C |
| YR05967 | SERUM P. | 0-12.1 g/dl | 0.1 | ±0.2 | Yes | 0-40°C |
| YR05968 | Refractive Index | 1.3330–1.3900nD | 0.0001nD | ±0.0003nD | Yes | 0-40°C |
Market Price
The current market landscape for digital refractometers forecasts an average price range for precise instruments such as these. Prices generally hover between 200 USD to 600 USD, reflecting the advanced technology and the precision provided. It’s essential to recognize this investment for its role in enhancing diagnostic accuracy and efficiency in laboratories and medical facilities worldwide.
Frequently Asked Questions
What makes the Digital Clinical Refractometer series stand out?
This series stands out due to its precision, range of applications, and automatic temperature compensation feature, ensuring consistent results regardless of environmental temperature changes.
How do I ensure the accuracy of my refractometer?
Maintaining the refractometer with regular calibrations, cleaning after use, and checking against standard samples can ensure consistent accuracy.
Is the refractometer suitable for field use?
Absolutely, the automatic temperature compensation and portability of the device make it ideal for various field applications.
Advantages and Disadvantages
Among the significant advantages of the Digital Clinical Refractometer series are its precision and range of application, notably in medical and laboratory settings. The automatic temperature compensation feature eliminates discrepancies caused by temperature variations, ensuring consistent accuracy. Additionally, the varied models accommodate different specific testing needs, making them versatile tools in any lab.
However, potential drawbacks may include the need for initial user training to maximize the device’s features and understand its operation thoroughly. Moreover, while portable, its advanced nature might demand careful handling to maintain its precision and longevity.
Field Use of the Product
The Digital Clinical Refractometer is a valuable tool for a wide range of field applications. In clinical settings, it enables quick assessments of urine specific gravity and serum protein levels, essential in diagnosing various health conditions. Laboratories can rely on its accuracy for research purposes, particularly where precision in refractive index measurements is crucial. Furthermore, its lightweight design and ATC capability allow for reliable performance in environments where temperature control is a challenge.
Field professionals find the refractometer’s durability and precision ideal for remote or outdoor applications, ensuring that high-quality data is accessible regardless of location.
Recommendations
For optimal performance, it is recommended to calibrate the refractometer regularly to maintain the highest level of accuracy. Users should follow the manufacturer’s guidelines diligently for calibration and cleaning procedures. It is also advised to store the refractometer in a stable environment when not in use, away from direct sunlight and extreme temperatures, to prevent any potential damage to the instrument.
Additionally, users are encouraged to leverage the Kalstein Plus platform to request a quotation effortlessly, taking advantage of personalized pricing options and further enhancing the purchase experience. The platform not only provides detailed product information but also allows customers to explore additional compatible products that may benefit their operations.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our online shopping channels, intuitive and agile, are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/digital-clinical-refractometer-yr05966-yr05968/.