Product Description
The **Multifunctional Imager YR06212** stands at the forefront of imaging technology, offering unparalleled precision and versatility for advanced scientific research. Designed for chemilluminescence and fluorescence imaging, this device is a cornerstone for disciplines requiring ECL and fluorescent Western Blotting. It’s also adept for Gel Documentation applications, making it indispensable in modern laboratories.
At its core, the YR06212 features a back-illuminated SCMOS sensor with an impressive resolution of 9.0 megapixels and pixel size of 3.76 × 3.76 μm. This enables it to capture intricate details with remarkable clarity. The regulated cooling system maintains the operating temperature at -30 ℃, ensuring consistent performance. Additionally, its dynamic range of 4.8OD and 16bit pixel density provide extensive grayscale depth, vital for detailed analysis.
The device comes equipped with an auto-focus lens, standard at F0.95, with an optional upgrade to F0.8. The sample tray setup is equally impressive, featuring fixed layers for various sizes of western blotting membranes and specific setups for DNA/RNA and protein gels. Complemented by SHST Capture and Analysis Software, this imager ensures sophisticated data handling and template processing, licensed for unlimited users.
| Model | YR06212 | |
| Application | Chemilluminescence Imaging, ECL Western Blotting | YES |
| Fluorescence Imaging, Fluorescent Western Blotting | YES | |
| Gel Doc Application | YES | |
| Protein gel; SDS Pages | YES | |
| Standard Parameters | Sensor | Back illuminated SCMOS Sensor |
| Resolution | 9.0 Megapixels | |
| Pixel Size | 3.76 × 3.76 μm | |
| Temperature | -30 ℃ regulated | |
| Dynamic Range | 4.8OD | |
| Pixel density | 16bit(65536 Grey scales) | |
| Lens | F0.95 as standard (optional F0.8) Auto Focus | |
| Chemilluminescence Sample tray | Fixed 4 layers sample trays for different sizes of western blotting membranes | |
| DNA/RNA detection | Fixed 1 layer UV transmission as standard | |
| Protein gel;SDS Pages | Fixed white LED Transmission for Protein Gels | |
| Software | SHST Capture and Analysis Software for unlimited number of users | |
| Optional Accessories | Epi-UV, RGB and NIR fluorescent detection; Connection to external PC; Blue LED transmission | |
Market Price
In the competitive landscape of imaging devices, the **Multifunctional Imager YR06212** holds its ground with a price range of approximately $19,000 to $20,000 USD. This range reflects the device’s advanced technology and comprehensive features, offering exceptional value in comparison to other market alternatives. The investment in such a high-precision tool boosts not only the efficiency but also the accuracy of laboratory findings.
Frequently Asked Questions
What applications is the YR06212 suitable for?
The YR06212 is ideal for Chemilluminescence Imaging, ECL and Fluorescent Western Blotting, along with Gel Documentation applications. It is well-suited for laboratories handling complex imaging requirements.
What sets the Back illuminated SCMOS Sensor apart?
This sensor allows for high sensitivity and low noise, providing outstanding image clarity even under low-light conditions, making it indispensable for accurate and detailed scientific analyses.
Advantages and Disadvantages
Among the significant advantages are its high-resolution imaging, versatile application capabilities, and robust software support. The regulated cooling system and auto-focus lens enhance precision, while optional accessories expand functionality. However, a potential drawback could be its upfront cost, which may be a consideration for smaller budgets.
Use of the Product in the Field
The **YR06212** demonstrates its effectiveness in various practical scenarios, especially in research institutions dealing with complex image processing and detailed molecular studies. Its ability to provide comprehensive imaging solutions, from DNA/RNA detection to detailed protein gel imaging, makes it an invaluable asset in any advanced research setting.
Researchers can leverage the device’s robust software for data analysis, improving their workflow efficiency and accuracy in results publication.
Recommendations
To maximize the YR06212’s potential, regular software updates and maintenance ensure it operates at peak performance. It’s advisable to utilize optional accessories for extended application capabilities and to integrate it with external PCs for enhanced data management.
For those interested in advancing their laboratory capabilities, consider exploring Kalstein’s **Kalstein Plus** platform to generate an automatic quotation and discover how this multifunctional imager can transform your research endeavors.
If you are looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a high level of excellence. Our online purchasing channels, intuitive and agile, are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/multifunctional-imager-yr06212/