Innovative Technical Mastery of Horizontal Cylindrical Pressure Steam Autoclaves

Product Description

The Horizontal Cylindrical Pressure Steam Autoclaves YR05635-YR05639 offer an exceptional sterilization solution designed for both efficiency and reliability. These autoclaves operate at a work pressure of 0.22 Mpa and maintain a work temperature of 134℃, suitable for a wide range of laboratory and clinical environments. With a working temperature range from 105-134℃, users have flexibility depending on their sterilization needs.

Each model, from YR05635 to YR05639, varies in chamber size, accommodating different volume needs ranging from 150L to 500L. The superior design ensures an average heat deviation of ≤±1℃, guaranteeing consistent performance. These autoclaves boast a sterilization time of up to 60 minutes and an equal drying time, combined with their energy efficiency ranging from 9kw to 18kw, making them a dependable choice for professionals.

Model YR05635 YR05636 YR05637 YR05638 YR05639
Work pressure 0.22Mpa
Work temperature 134℃
Working temperature range 105-134℃
Sterilization time 0 – 60 minutes
Drying time 0 – 60 minutes
Average heat ≤±1℃
Chamber size (mm) 150L / Ø440×1000 200L / Ø500×1000 300L / Ø600×1080 400L / Ø700×1100 500L / Ø700×1300
Outer size (mm) 1400×600×1300 1400×670×1650 1400×770×1780 1430×880×1830 1800×900×1820
Packing size (mm) 1550×750×1850 1560×820×1850 1680×920×2100 1600×1050×2100 1850×1050×2100
GW / NW 320/240kg 350/260kg 465/365kg 530/420kg 580/470kg
Energy 9kw 9kw 12kw 18kw 18kw

Market Price

The price of horizontal cylindrical pressure steam autoclaves can vary depending on their features and capacity. This particular product is positioned in the market within a competitive range, typically averaging between $12,800 and $13,600 USD. This pricing reflects its high-performance capabilities and technological advancements that cater to professional sterilization needs.

Given its advanced design and robust build, investing in this autoclave is a strategic choice for laboratories and healthcare facilities seeking reliable sterilization solutions without compromising quality.

Frequently Asked Questions

What is the maximum sterilization and drying time?

The autoclaves offer up to 60 minutes for both sterilization and drying, accommodating various sterilization cycles based on user requirements.

How does the unit ensure temperature consistency?

The device maintains exceptional temperature consistency with an average heat deviation of ≤±1℃, providing reliable and uniform sterilization results.

Is the unit energy efficient?

Yes, the autoclaves feature energy settings ranging from 9kw to 18kw, optimized for performance without excessive power consumption.

Advantages and Disadvantages

Advantages: The main advantages of these autoclaves include their high-temperature range, large capacity options, consistent temperature maintenance, and quick operation times. These features make them ideal for handling large loads and achieving thorough sterilization efficiently.

Disadvantages: Potential disadvantages might include higher initial investment costs compared to smaller, less advanced autoclave models and the requirement for adequate space due to their robust size.

Product Usage in the Field

In practical use, these autoclaves are integral to laboratories and hospitals where effective sterilization of medical tools and laboratory equipment is paramount. Their efficient operation ensures rapid turnover of instruments, crucial in high-demand medical environments.

Researchers and professionals appreciate their ease of use and the reliability they bring to critical sterilization tasks, allowing for seamless integration into existing workflows and operational protocols.

Recommendations

To maximize the utility and lifespan of these autoclaves, regular maintenance and calibration checks are recommended. Users should ensure that autoclaves receive consistent power supply and that they follow manufacturer guidelines for optimal performance.

Furthermore, proper training of personnel on operational best practices can significantly enhance the efficiency and safety of autoclave use, leading to better outcomes in sterilization processes.

If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with an unparalleled level of excellence. Our intuitive and agile online sales channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life, and it’s time to be part of our community. Explore the product.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]