Innovative Laminar Flow Cabinet YR05744: Key Features and Applications

Product Description

The Laminar Flow Cabinet YR05744 stands at the forefront of precision laboratory equipment, engineered to ensure a contamination-free environment essential for sensitive processes. With its vertical air supply, this cabinet maintains a consistent flow across the workspace, enabling a cleanliness level of Class 100@≥0.5μM according to US Federal Standard 209E. The meticulous design ensures that the number of colonies remains ≤0.5pcs/dish·hour when using a 90mm culture plate, creating a secure barrier against airborne contaminants.

This model is designed to operate at average wind speeds ranging from 0.25 to 0.45 m/s, which can be adjusted for both fast and slow operations. Despite its high efficiency, the noise levels are kept at a moderate ≤62dB(A), and vibration peaks at a low ≤5μM across all directions (x, y, z). The cabinet is also equipped with excellent illumination with illuminance levels at ≥300Lx, optimizing the visibility of the working area.

Model YR05744
Air Supply Vertical Air Supply
Cleanliness level Class 100@≥0.5μM (US Federal 209E)
Number of colonies ≤0.5pcs/dish·hour (Φ90mm culture plate)
Average Wind Speed 0.25~0.45m/s(Fast and slow)
Noise ≤62dB(A)
Vibration half peak ≤5μM(x、y、z direction)
Illuminance ≥300Lx
Power Supply AC single-phase 220V/50Hz
Max. Power Consumption 400W
Working area 700x600x700
Overall dimension 860x760x1760
Specification and quantity of high efficiency filter 685x540x50 x 1
Specification and quantity of fluorescent lamp/ultraviolet lamp 12Wx1 / 20Wx1
Applicable Persons Single person-single side

Market Price

While the Laminar Flow Cabinet YR05744 offers cutting-edge features, it is also competitively priced within the market. Generally, laminar flow cabinets with similar specifications range from approximately $1900 to $2600. This makes it an affordable investment for labs in need of reliable and robust contamination control solutions. As you consider this essential equipment, remember that ensuring controlled environmental conditions not only upholds scientific integrity but also optimizes operational efficiency.

Frequently Asked Questions

What is the main function of the YR05744 Laminar Flow Cabinet?

The primary purpose of the YR05744 is to maintain a sterile and particle-free environment to protect sensitive samples from contamination.

Can this cabinet be used for medical laboratories?

Yes, the YR05744 is suitable for use in medical, pharmaceutical, and research laboratories that require a controlled clean air environment.

How often should the filters be replaced?

It depends on the usage and environmental conditions, but generally, the filters should be inspected semi-annually and replaced if they show signs of wear or contamination.

Advantages and Disadvantages

Advantages: The YR05744 boasts advanced air filtration that ensures high cleanliness levels, ideal for critical laboratory tasks. Its energy-efficient design optimizes power usage while maintaining performance stability. The cabinet’s ergonomic design, featuring advanced illumination, enhances user comfort and accuracy in tasks performed within the unit.

Disadvantages: The unit is designed for single-person usage, which may limit its applicability in settings requiring simultaneous multi-user access. Additionally, the reliance on electrical power means contingency plans should be in place in case of power failures.

Product Use in the Field

In practical applications, the YR05744 is instrumental in laboratory settings where precision and contamination control are imperative. This laminar flow cabinet is utilized in microbiology, pharmaceutical production, and research labs, where it supports activities such as cell culture and media preparation. By providing a contamination-free work zone, it aids in maintaining high standards of experimental accuracy and reliability.

The construction of the cabinet ensures ease of use and minimal maintenance, allowing users to concentrate on their work without interruption. The efficient airflow system reduces the risk of cross-contamination, making it indispensable for environments where safety and hygiene are paramount.

Recommendations

To maximize the lifespan and efficiency of your YR05744 Laminar Flow Cabinet, regular maintenance checks are essential. It is advisable to have filtering systems assessed by professionals periodically to ensure optimal performance. Calibration of airflow speeds should be done following the manufacturer’s guidelines to maintain the cleanliness standards.

In addition, consider organizing workspace layouts to accommodate the single-user design effectively. Ensure proper employee training on operating protocols to uphold the cabinet’s efficiency and safety. When not in use, the unit should be kept clean and utilized in a stable environment to minimize undue wear and tear.

If you are looking for a fusion of innovation and quality, you have arrived at the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer; we bring science to life and invite you to be part of our community. https://kalstein.net/en/product/laminar-flow-cabinet-yr05744/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]