Product Description
The Pulsed Xenon Lamp Benchtop Spectrophotometer, model YR05475, stands at the forefront of color measurement technology, offering precision and versatility for a wide range of applications. Its advanced optical geometry provides options for both reflectance (d/8) and transmittance (d/0) measurements, incorporating SCI & SCE with both UV inclusion and exclusion capabilities. This spectrophotometer conforms to international standards such as CIE No.15, ISO7724/1, and ASTM E1164, ensuring high reliability and accuracy.
Equipped with a Φ154mm integrating sphere, the device employs a pulsed xenon lamp with a wavelength range from 360nm to 780nm, paired with a 400nm cut-off to ensure optimal performance. The spectrophotometric mode utilizes concave grating and a 256 image element double array CMOS image sensor, delivering high-fidelity measurements with a wavelength pitch of 10nm and a semiband width of 5nm. Its reflectance range spans from 0 to 200%, accommodating a variety of samples with different optical properties.
The device features multiple measuring apertures, including reflective and transmissive modes, with options for custom configurations to meet specific needs. Its comprehensive color space options, including CIE Lab, XYZ, and HunterLab, among others, allow detailed color analysis with accurate color difference formulas such as ΔE*ab and ΔE*94. The spectrophotometer also supports a range of illuminants like D65, C, and UV to simulate various lighting conditions. A vivid 7″ TFT display enhances user interaction, while data storage is robust, accommodating up to 20,000 samples.
| Model | YR05475 (Pulsed xenon lamp) |
| Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
| Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003) | |
| Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
| Integrating Sphere Size | Φ 154mm |
| Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Pitch | 10nm |
| Semiband Width | 5nm |
| Reflectance Range | 0~200% |
| Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE |
| Transmittance: SCI&SCE | |
| Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
| Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
| Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
| Observer Angle | 2° & 10° |
| Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
| Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
| Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
| Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
| (Average for 12 BCRA Series II color tiles) | |
| Size | 370×300×200mm |
| Weight | About 9.6kg |
| Power Supply | DC 24V, 3A Power Adapter |
| Light Source Device Life | 5 years, more than 3 million times measurements. |
| Display | 7″ TFT Capacitive Screen-touch Display |
| Data Port | USB & Print serial port |
| Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
| Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
| Optional Accessory | Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
| Notes: The specifications are subject to change without notice. | |
Market Price
When it comes to investing in cutting-edge spectrophotometry tools, understanding the cost spectrum is essential. For a spectrophotometer like the Pulsed Xenon Lamp Benchtop model YR05475, prices on the market generally range from $10,000 to $11,000. This investment ensures access to top-tier technology and precise operations, vital for any top application in scientific research or quality control.
Although the initial cost may seem substantial, the longevity and capability of this spectrophotometer, coupled with its advanced features, justify the expenditure. It is an indispensable tool for professionals who require reliable and repeatable color measurement data, providing significant value over time. Contacting suppliers for a customized quote can open up possibilities for tiered pricing or promotional offers. Request your personalized quote today through Kalstein Plus and discover a world of precision!
Frequently Asked Questions
What makes the pulsed xenon lamp technology advantageous?
The pulsed xenon lamp technology provides a broad wavelength range (360nm-780nm) and intense light power, making it suitable for various colorimetric and photometric tests.
Is it easy to integrate the spectrophotometer into existing laboratory workflows?
Yes, the spectrophotometer features a user-friendly interface and data ports like USB for smooth connectivity and integration with current laboratory systems.
Can the device support multilingual operations?
Indeed, the spectrophotometer offers language support in Simplified Chinese, Traditional Chinese, and English, enhancing accessibility for diverse laboratory environments.
Advantages and Disadvantages
The Pulsed Xenon Lamp Benchtop Spectrophotometer boasts numerous advantages, starting with its comprehensive measurement capabilities that cater to both transmittance and reflectance. Its high level of precision and conformity to international standards makes it an asset for achieving consistent results. The advanced xenon lamp offers reliable performance over 5 years or more than 3 million measurements, reducing maintenance concerns.
On the downside, the equipment’s sophistication might require users to undergo training to maximize its potential, especially for those unfamiliar with advanced spectrophotometric techniques. Additionally, the initial investment cost can be steep for smaller operations, however, the cost-effectiveness is evident in long-term usage and performance.
Product Usage in the Field
This spectrophotometer is extensively utilized in quality control laboratories, research facilities, and any environment requiring meticulous color measurements. It aids in evaluating material properties, ensuring color consistency in product manufacturing, and conducting rigorous scientific research. Whether in the chemical, textile, or paint industries, its adaptability and precision enable users to maintain strict adherence to required standards.
Furthermore, its rapid measuring time and automatic device settings enhance workflow efficiency, making it suitable for high-throughput environments. Its reliable interfacing capabilities allow easy data sharing and detailed analysis in real-time contexts, contributing significantly to speedy decision-making and process improvements.
Recommendations
To ensure optimal performance of the Pulsed Xenon Lamp Benchtop Spectrophotometer, it’s crucial to follow regular calibration schedules using the included calibration board and cavity. This routine preserves measurement precision and reliability. Storing the device in an environment within its specified temperature and humidity range extends its service life.
Users are advised to periodically check the condition of custom configurations for measuring apertures and lenses to maintain versatility and accuracy. Participating in brief training sessions or workshops can further enhance understanding and operational efficiency, allowing users to fully exploit the spectrophotometer’s capabilities. Remember, a small investment in preventive maintenance can yield substantial gains in output quality and longevity.
If you are searching for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each device with a level of excellence. Our intuitive and flexible online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to join our community. Product Link.