Product Description
The Microplate Washer YR05126 is a sophisticated laboratory device designed to automate and improve the efficiency of washing microplates. This model supports a 96-well plate or strip configuration, making it versatile and suitable for various assays and laboratory applications. With a residual volume of less than 1µl, it ensures minimal waste and maximum reagent utilization, which is vital for achieving precise test results.
This microplate washer offers a washing volume ranging from 50 to 3000µl per well, with continuous adjustments available between 10µl and 50µl. It allows for up to 99 washing cycles, ensuring thorough cleaning of plates. Featuring the capability to wash two plates simultaneously and programmable strip washing for 1 to 8 strips, the YR05126 promises to enhance laboratory productivity. With soaking and shaking times programmable from 0 to 24 hours and a large LCD display for easy operation, this device is user-friendly and efficient.
In the realm of connectivity and data management, the YR05126 has 5 washing channels—3 for washing, 1 for rinsing, and 1 for waste management, alongside the ability to store up to 100 washing protocols and 10 plate protocols. The RS-232 interface ensures compatibility with various laboratory setups for seamless data export and management. This washer operates on an AC 110/220V±10%, 50±1 HZ power supply, weighs 23.8 kg, and has dimensions of 610×460×240 mm, making it suitable for most lab environments.
| Model | YR05126 |
| Plate Mode | 96-well plate or strip |
| Residual Volume | <1µl |
| Washing Volume | 50~3000µl/well, 10/50µl continuously adjustable |
| Washing Cycle | Up to 99 cycles |
| Strip Washing | Wash 2 plates at a time, 1-8 strips programmable |
| Soaking Time | 0~24 hours |
| Shaking Time | 0~24 hours |
| Display | Large LCD |
| Wash Channels | 5 channels, 3 for wash, 1 for rinse and 1 for waste |
| Memory | 100 washing protocols & 10 plate protocols |
| Interface | RS-232 |
| Power Requirement | AC 110/220V±10%, 50±1 HZ |
| Net Weight | 23.8 kg |
| Dimension L×W×H(mm) | 610×460×240 |
Market Price
The Microplate Washer YR05126 is priced competitively in the market, typically ranging between $5,500 and $6,300 USD. This range reflects the advanced features and robust performance of this device, making it a valuable investment for laboratories focused on precision and efficiency. While exploring this range, potential buyers can leverage the Kalstein Plus platform to generate an automatic quotation and explore financial options that best align with their budgetary constraints.
Frequently Asked Questions
What types of microplates are compatible with the YR05126?
This washer is compatible with 96-well plates or strips, offering flexibility for various assays.
Is the washing volume adjustable?
Yes, the washing volume can be continuously adjusted between 50 to 3000µl per well.
How many washing protocols can be stored in the device?
The YR05126 can store up to 100 washing protocols and 10 plate protocols for efficient data management.
Advantages and Disadvantages
Advantages: The Microplate Washer YR05126 is highly efficient, capable of washing two plates simultaneously or up to 8 strips, which significantly reduces manual labor and increases throughput. The large LCD display and RS-232 interface contribute to a seamless user experience and integration into laboratory networks.
Disadvantages: Although highly functional, some laboratories might find the initial investment cost high. Additionally, the device requires careful handling to ensure its longevity and accuracy.
Use of the Product in the Field
The YR05126 is extensively used in clinical laboratories, research facilities, and pharmaceutical industries for ELISA tests, cell-based assays, and any protocols that require precise and thorough washing of microplates. Its ability to adjust to various plate formats and cycle settings makes it a versatile tool for enhancing the efficiency and accuracy of experimental results.
By automating the washing process, this device allows lab personnel to focus on more critical tasks, thus optimizing the overall workflow and productivity in busy lab settings.
Recommendations
To maximize the performance of the Microplate Washer YR05126, it is recommended to regularly calibrate the device and clean the channels to prevent clogs. Users should familiarize themselves with the programming of washing and plate protocols to fully utilize the device’s memory capabilities. Additionally, laboratory personnel should routinely check for software updates to maintain optimal compatibility with laboratory management systems.
If you are considering upgrading your laboratory’s equipment, the Microplate Washer YR05126 offers unmatched efficiency and reliability. We invite you to request a quotation through our Kalstein Plus platform to explore potential investment opportunities.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment to a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/microplate-washer-yr05126/.