Infant Incubator YR02187: Advanced Features and Precise Control

Product Description

The Infant Incubator YR02187 is a state-of-the-art medical equipment designed to provide a stable and controlled environment for newborns requiring special care. This incubator features an intuitive LCD display that allows healthcare professionals to monitor and adjust the settings with precision. The robust electrical system offers compatibility with ~220V 50Hz or ~230V 60Hz power inputs, ensuring adaptability in different regions.

The system’s power consumption is kept under 550VA, making it energy efficient. The YR02187 offers comprehensive temperature control with an air mode range from 25.0°C to 37.0°C and a skin mode range from 25.0°C to 37.0°C. Its sophisticated high-temperature alarm systems are vital for maintaining safety, with air and skin mode alarms at ±3.0°C and ±1.0°C, respectively.

Additional features include precise humidity control ranging from 30%RH to 90%RH and optional O2 control from 20% to 60%. The incubator provides a quiet atmosphere with noise levels kept at or below 55dB(A), promoting a serene environment for the infant.

Model YR02187
Display LCD
Electrical requirement ~220V 50Hz or ~230V 60Hz
Power consumption ≤550VA
Air mode temperature range 25.0°C~37.0°С
Skin mode temperature range 25.0°C~37.0°C
Air over temperature range <38.0°C
Air mode high temperature range 37.1°C~39.0°C
Skin mode high temperature range 37.1°C~38.0°C
High temperature mode alarm < 40.0°C
Air mode alarm ±3.0°C
Skin mode alarm ±1.0°C
Skin sensor accuracy ≤±3.0°C
Air control accuracy ≤0.5°C
Mattress temperature uniformity <0.8°C
Humidity control range 30%RH-90%RH
O2 control range (option) 20%-60%
O2 display accuracy (option) ±3%
Electrical scale weight range (option) 0.1kg-8.0kg
Electrical scale display range (option) ±50g
Noise ≤55dB(A)

Market Price

The Infant Incubator YR02187 falls within a competitive price range for high-precision neonatal care equipment. The market offers this advanced incubator at a price ranging from approximately 5200 USD to 6100 USD, considering its sophisticated features and reliability in newborn care facilities. Hospitals and medical practitioners looking to invest in an incubator will find the YR02187 to be a valuable asset, balancing affordability with state-of-the-art technology.

Frequently Asked Questions

What is the power requirement for the YR02187 incubator?

The unit operates efficiently with electrical requirements of ~220V 50Hz or ~230V 60Hz, making it suitable for various regional electrical sectors.

How accurate is the temperature control of the incubator?

The YR02187 offers precise control with an air mode accuracy of ≤0.5°C and a skin sensor accuracy of ≤±3.0°C, ensuring the environment is stable for neonatal care.

Is there an option for oxygen control in this incubator model?

Yes, the YR02187 includes an optional O2 control range of 20% to 60%, with a display accuracy of ±3%, enhancing critical care for infants in need of supplemental oxygen.

Pros and Cons

Pros: The Infant Incubator YR02187 is packed with advanced features like precise temperature control, humidity adjustments, and optional O2 control, all with a quiet operation (≤55dB(A)). These attributes make it invaluable for neonatal intensive care units needing reliable and controlled care environments for infants.

Cons: While the incubator is feature-rich, the initial investment is higher compared to basic models, though the advanced capabilities often justify the cost.

Product Usage in the Field

Used predominantly in neonatal intensive care units (NICUs), the YR02187 incubator provides a controlled and comfortable environment essential for the health and recovery of premature or vulnerable newborns. Its ability to regulate temperature, humidity, and oxygen levels makes it an indispensable tool for medical staff focusing on specialized neonatal care.

The LCD interface supports healthcare providers in easily monitoring and responding to the needs of infants, making adjustments as required to ensure optimal conditions within the incubator. This intuitive control enhances the caregiver’s ability to provide immediate and effective interventions.

Recommendations

For optimal performance and prolonged life of the Infant Incubator YR02187, maintenance must be conducted periodically following the manufacturer’s guidelines. It is essential to keep the unit clean and ensure all sensors are functioning accurately. Consistent monitoring of the device’s alerts and alarms will ensure that babies receive appropriate care promptly. Additionally, getting a professional calibration periodically will sustain the reliability and accuracy of the incubator’s performance.

If you’re looking for a blend of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of browsing through our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and fast online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, and it’s time to become part of our community. https://kalstein.net/en/product/infant-incubator-yr02187/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]