Innovative Features of Infant Radiant Warmer YR02193

Product Description

The Infant Radiant Warmer YR02193 is a cutting-edge medical device designed to provide optimal thermal support to newborns, ensuring their comfort and safety during the crucial early hours of life. This model is recognized for its cutting-edge features and superior technical specifications that make it a top choice for neonatal care units around the world.

Key technical specifications of the YR02193 include its electrical requirements of ~220V 50Hz or ~230V 60Hz, with a power consumption of ≤700VA. The device features an air mode temperature range from 25.0°C to 37.0°C and is equipped with an over-temperature alarm that triggers at <38.0°C to prevent overheating. The high mode temperature range extends from 37.1°C to 38.0°C, with a temperature alarm set for any measure <39.0°C, ensuring continual monitoring and safety.

The device also boasts a skin sensor accuracy of ≤±0.3°C and ensures mattress temperature uniformity within ≤2.0°C, supporting consistent and reliable thermal environments for infants. With a heating rate ≤30 minutes, healthcare practitioners can quickly reach the desired temperature, alongside an APGAR timing feature for monitoring at 1 minute, 5 minutes, and 10 minutes after birth.

Model YR02193
Electrical requirement ~ 220V 50Hz or ~ 230V 60Hz
Power consumption ≤700VA
Air mode temperature range 25.0°C-37.0°C
Over temperature alarm <38.0°C
High mode temperature range 37.1°C ~ 38.0°C
High mode temperature alarm < 39.0°C
Temperature deviation alarm ±1.0°C
Skin sensor accuracy ≤±0.3°C
Mattress temperature Uniformity ≤2.0°C
Heating rate ≤30min
APGAR timing 1min. 5min. 10min

Market Price

The YR02193 Infant Radiant Warmer is competitively priced in the market, making it accessible for medical facilities committed to delivering superior neonatal care. Typically, the price range for this device varies between $4800 and $5600 USD, reflecting its advanced technology and trusted performance in the field. This investment is justified by the significant role it plays in safeguarding newborn health, providing a controlled and safe environment during the critical period post-birth.

Frequently Asked Questions

What makes the YR02193 Infant Radiant Warmer unique?

The YR02193 features highly accurate temperature controls and alarms, which ensures a stable and safe environment for infants. Its rapid heating capabilities and APGAR timing functionality set it apart from competitors.

Can the device be used in a home setting for neonatal care?

While the YR02193 is primarily designed for hospital and clinical use, its reliable features make it a valuable option for dedicated neonatal care at home, provided that the user is trained in its operation and maintenance.

How does the APGAR timing feature help healthcare professionals?

APGAR timing facilitates the observation of an infant’s health over the first minutes of life, providing a quick overview of the newborn’s physical condition and progress, allowing for prompt medical intervention if necessary.

Advantages and Disadvantages

Advantages:

  • Offers precise temperature control, ensuring infant safety.
  • Features reliable alarm systems to prevent overheating.
  • Quick heating rate ensures timely setup and use.
  • APGAR timing enhances neonatal monitoring.

Disadvantages:

  • Higher initial cost compared to basic models.
  • Requires professional setup and occasional maintenance checks.

Product Use in the Field

The YR02193 Infant Radiant Warmer is primarily employed in neonatal intensive care units and maternity wards, where maintaining a consistent and warm environment for newborns is paramount. The device’s precision sensors and alarms allow medical practitioners to easily monitor and adjust the conditions, ensuring that each infant receives care tailored to their individual needs.

The APGAR timing function also plays a vital role by helping healthcare professionals evaluate infant conditions immediately after birth, offering crucial data to inform treatment and care. In scenarios requiring rapid thermal interventions, the YR02193 excels by achieving desired temperatures within 30 minutes, facilitating quick accommodation of medical needs.

Recommendations

For optimal use of the YR02193 Infant Radiant Warmer, it is recommended that facilities undergo routine inspections to ensure continued performance accuracy. Training sessions should be held for staff to familiarize themselves with the device’s features and alarms, allowing for quick response times in critical situations. Regular maintenance checks are essential to sustain durable operation and prevent potential malfunction.

If you are actively looking to enhance neonatal care, then leveraging the capabilities of YR02193 in your practice would be a decision toward quality healthcare. For seamless acquisition, you might want to explore our Kalstein Plus platform to request a full quotation or initiate purchase discussions with ease and efficiency.

Si está buscando una fusión de innovación y calidad, has llegado al lugar correcto. En Kalstein te ofrecemos el lujo de explorar nuestro exclusivo catálogo de equipos de laboratorio. Fabricamos cada equipo con un nivel de excelencia. Nuestros canales de compra online, intuitivos y ágiles, están diseñados para su comodidad, asegurando los precios más amigables. No dude más, le damos vida a la ciencia, es hora de hacer parte de nuestra comunidad. https://kalstein.net/en/product/infant-radiant-warmer-yr02193/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]