Product Description
The YR05188 Benchtop Manifold Freeze Dryer stands out for its cutting-edge design and superior functionality, making it a prominent choice for laboratories seeking efficient and reliable freeze-drying solutions. With a compact freeze-drying area of 0.12㎡ and a condenser capacity of 3-4 L per 24 hours, this device is engineered to cater to various laboratory demands. The condenser temperature reaches -55℃, offering an optional upgrade to an impressive -80℃, ensuring optimal conditions for sensitive samples.
Featuring a robust design, the YR05188 has a vacuum degree of less than 10 Pa, which guarantees an optimal freeze-drying environment. Its material tray, with a diameter of 200 mm across four layers, offers ample space for diverse sample sizes. In terms of bulk capacity, it accommodates 1.2 liters with a thickness of 10 mm, providing versatility in handling samples of different consistencies.
Moreover, the YR05188 is outfitted with an adaptable manifold equipped with eight ports and includes flasks of varying sizes—1000 ml, 500 ml, 250 ml, and 100 ml—ensuring compatibility with a wide range of laboratory needs. Its cooling system operates seamlessly at ambient temperatures up to 25℃, supported by air ventilation that maintains stable and efficient operations.
| Model | YR05188 |
| Freeze drying area | 0.12㎡ |
| Condenser capacity | 3-4 L /24h |
| Condenser temperature | -55℃ (-80 ℃ optional) |
| Vacuum degree | < 10 Pa |
| Material tray | Ф200mm, 4 layers |
| Bulk capacity | 1.2L, 10mm thickness |
| Vial capacity Φ12mm | 920 pcs |
| Vial capacity Φ16mm | 480 pcs |
| Vial capacity Φ22mm | 260 pcs |
| Manifold | with 8 ports |
| Flask | 1000ml, 500ml, 250ml, 100ml |
| Cooling | Air, draughty, ambient temperature ≤25℃ |
| Voltage | 220V, 50 Hz; 110V, 50Hz; 110V, 60Hz |
| Power | 700W |
| Dimension | 460×625×(370+465) mm |
| Host weight | 41 kg |
Market Price
The market price for the YR05188 Benchtop Manifold Freeze Dryer averages around $5,400 to $6,200 USD. This competitive pricing reflects its advanced features and the efficiency it offers to laboratory professionals. Investing in this freeze dryer means leveraging highly specialized technology to meet the dynamic needs of scientific exploration.
Frequently Asked Questions
What is the primary application of the YR05188 Freeze Dryer?
This freeze dryer is primarily used for preserving perishable materials, ensuring the retention of their biological and chemical integrity.
Does the YR05188 model accommodate different flask sizes?
Yes, it comes with flasks of varied sizes, including 100ml, 250ml, 500ml, and 1000ml, making it suitable for different experimental requirements.
Can the condenser temperature be adjusted?
Absolutely, the YR05188 freeze dryer offers a base condenser temperature of -55℃, with an optional upgrade to -80℃ for handling more sensitive samples.
Advantages and Disadvantages
The YR05188 Freeze Dryer offers several advantages, including high efficiency, flexibility in sample sizes, and an advanced manifold system with eight ports. Its powerful cooling and vacuum capabilities allow it to process samples quickly while maintaining their essential properties.
However, potential users should also be aware of the initial cost associated with acquiring such specialized equipment, which may be higher than simpler freeze dryers. Additionally, its weight, being 41 kg, might require consideration for lab space planning.
Use of the Product in the Field
In practical scenarios, the YR05188 Freeze Dryer is employed across various industries, from pharmaceuticals to biological research. Its use spans the freeze-drying of delicate biomaterials, where maintaining cell structure and viability is crucial. Laboratories utilize this model for critical sample preparation, ensuring stability during long-term storage.
This equipment is invaluable in chemical laboratories conducting experiments where the removal of solvents at low temperatures is necessary, preserving the chemical structure and potency of compounds.
Recommendations
To ensure the longevity and optimal performance of the YR05188 Freeze Dryer, it is recommended to perform regular maintenance checks, particularly for its vacuum pumps and cooling systems. It is also advisable to operate the equipment in a clean, well-ventilated environment to prevent any contaminants from affecting the samples or the device itself.
Utilizing the manifold’s full potential by organizing sample loading effectively can also enhance throughput and efficiency, making the most of the eight available ports.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer; we bring science to life. It’s time to become part of our community. https://kalstein.net/en/product/benchtop-manifold-lab-freeze-dryer-yr05188/.