The YR05733 Vertical Air Supply Clean Bench is an essential tool in maintaining laboratory precision. This state-of-the-art device features a vertical airflow design, which ensures a consistent and sterile environment. It achieves a cleanliness level of Class 100@≥0.5μM as per the US Federal 209E standards, providing optimal conditions for sensitive procedures.

Its robust design is tailored to support double person use on a single side, making it a versatile addition to any lab. One of the key highlights is its advanced airflow control, with an average wind speed of 0.25~0.45m/s, facilitating both fast and slow operational modes.

Model YR05733
Air Supply Vertical Air Supply
Cleanliness level Class 100@≥0.5μM (US Federal 209E)
Number of colonies ≤0.5pcs/dish·hour (Φ90mm culture plate)
Average Wind Speed 0.25~0.45m/s(Fast and slow)
Noise ≤62dB(A)
Vibration half peak ≤5μM(x、y、z direction)
Illuminance ≥300Lx
Power Supply AC single-phase 220V/50Hz
Max. Power
Consumption
800 W
Working area
W1×D1×H1
1 1 40 x 580 x 700
Overall dimension
W×D×H
1 300 x 760 x 1 760
Specification and quantity of high efficiency filter 1125 x 540 x 50 x 1
Specification and quantity of fluorescent lamp/ultraviolet lamp 20W x 1 / 36W x 1
Applicable Persons Double person-single side

Market Price

The market price for the YR05733 Vertical Air Supply Clean Bench typically ranges from $2,500 to $3,400 USD, offering competitive pricing given its advanced features and benefits. This range ensures that buyers receive exceptional value for a sophisticated piece of laboratory equipment, making it an attractive choice for facilities that prioritize precision and cleanliness.

Potential buyers are encouraged to explore special offers and promotions available on platforms like Kalstein Plus, offering additional savings and conveniences for bulk or institutional purchases.

Frequently Asked Questions

What are the primary benefits of using a vertical air supply clean bench?

This type of clean bench offers a directed airflow that minimizes cross-contamination, ideal for sensitive tasks in microbiology, pharmaceuticals, and electronics.

How often does the filter need to be replaced?

Filter replacement frequency depends on usage conditions, but generally, it is recommended every 12-18 months to maintain optimal performance.

Is the YR05733 suitable for double person use?

Yes, it is designed to accommodate two users on a single side, enhancing its functionality and efficiency in laboratory settings.

Advantages and Disadvantages

Advantages: The YR05733 model enhances laboratory efficiency through its Class 100 cleanliness level, ensuring a contamination-free environment. Its dual speed settings offer flexibility for various experimental needs. Additionally, low noise and vibration levels contribute to a comfortable working atmosphere.

Disadvantages: One potential drawback is the requirement for a stable single-phase 220V/50Hz power supply, which might not be readily available in all regions. Furthermore, its size and weight could necessitate significant space and mobility considerations within your facility.

Product Use in the Field

In practice, the YR05733 Vertical Air Supply Clean Bench is utilized across diverse fields, including biotechnology, pharmaceuticals, and electronics, wherever sterile environments are non-negotiable. Its vertical airflow design aids in containing particulate contamination, crucial for settings demanding sterile specimen handling.

Many laboratories have reported improved workflow and safety standards since integrating the YR05733 into their workplace environment, affirming its reliability and functionality in demanding laboratory conditions.

Recommendations

To extract maximum performance from your YR05733 clean bench, ensure regular maintenance checks, focusing on the filters and airflow mechanisms. It’s advisable to conduct periodic cleanliness assessments to comply with industry standards, thus maintaining the integrity of your experimental results.

Moreover, integrating this equipment into your lab through Kalstein Plus enables easy access to technical support and spare parts, ensuring your operations remain smooth and efficient. Consider reaching out for a personalized demonstration or quote to see how this clean bench can revolutionize your laboratory work.

If you’re seeking a fusion of innovation and quality, you’ve arrived at the right place. At Kalstein, we offer you the luxury of exploring our exclusive lab equipment catalog. We manufacture each piece of equipment with an unparalleled level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, and it’s time to become part of our community. https://kalstein.net/en/product/horizontal-air-supply-clean-bench-yr05733/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]