Product Description
The Gel Documentation Systems, models YR06063 and YR06064, are state-of-the-art solutions designed to provide unparalleled imaging capabilities for various laboratory applications. Both models feature a high-resolution monochrome scientific digital camera, essential for capturing fine details in gel electrophoresis results. The YR06063 model boasts a robust resolution of 5 Megapixels with 2592*1944 pixels, while the YR06064 takes it further to an impressive 20 Megapixels and 4800*4440 pixels. This significant difference enhances the documentation quality for highly detailed analyses.
These systems come equipped with a 16-bit A/D pixel density and support an extraordinary 65,536 grey scales, ensuring superior sensitivity and dynamic range. Sensitivity is a vital aspect, with YR06063 detecting DNA samples as low as ≤10pg of EtBr-stained DNA and YR06064 pushing the limits further to ≤5pg. The motorized lens eliminates the need for manual focus, freeing users from the hassle of frequent adjustments.
The systems incorporate a UV 302nm transmission area of 21×26 cm, coupled with a white LED transmission plate of 19×26 cm, providing flexibility and efficiency in illumination. The standard gel documentation filter ensures accuracy in capturing fluorescence without interference. Image acquisition and analysis software offered do not require a software dongle, allowing unlimited user access and free updates, making this an ideal choice for efficient laboratory operations.
Model | YR06063 | YR06064 |
---|---|---|
Camera type | Monochrome scientific digital camera | |
Resolution | 5 Megapixels, 2592*1944 | 20 Megapixels, 4800*4440 |
A/D, Pixel density | 16bit | |
Grey scales | 65536 | |
Lens | Motorized Lens, no manual focus required | |
Sensitivity | ≤10pg EtBr Stained DNA samples | ≤5pg EtBr Stained DNA samples |
UV transmission | Wavelength 302nm, Area: 21x26cm | |
White LED transmission | Real LED transmission plate, Area 19x26cm | |
Filter | Standard gel doc filter | |
Image Acquisition S/W | No software dongle required, free update, unlimited users | |
Image Analysis S/W | No software dongle required, free update, unlimited users |
Market Price
In today’s competitive market, the Gel Documentation Systems YR06063 and YR06064 are priced based on their advanced capabilities and cutting-edge features. Typically, prices for such high-end laboratory equipment range from approximately $6300 to $7100 USD. This is a worthy investment considering the precision and efficiency these systems bring to molecular biology and biochemistry laboratories worldwide. To receive a more precise quotation tailored to your needs, reach out to us directly or generate an automatic quote via the Kalstein Plus platform.
Frequently Asked Questions
What is the primary function of the Gel Documentation System?
The primary function is to capture and analyze images of electrophoresis gels used in molecular biology for DNA, RNA, and protein analysis.
Do I need any special software to operate these systems?
No, both image acquisition and analysis software are provided without the need for a software dongle, allowing unlimited users and free updates.
How does the motorized lens benefit me?
The motorized lens eliminates manual focus needs, speeding up the imaging process and reducing user intervention.
Advantages and Disadvantages
The Gel Documentation Systems offer numerous advantages, such as high resolution, sophisticated sensitivity, broad grey scales, and a powerful motorized lens, which collectively ensure outstanding image quality and data accuracy. Additionally, the intuitive software allows for easy operation and analysis. However, like any advanced lab equipment, the initial cost can be a barrier for smaller laboratories or institutions with limited budgets. Despite this, the long-term benefits in efficiency and data precision often justify the investment.
Product Use in the Field
In practical field applications, these systems are invaluable for researchers conducting experiments in genetics, microbiology, or any field requiring DNA, RNA, or protein analysis. The systems efficiently document gel electrophoresis results, ensuring that key experiment data is recorded accurately and is retrievable for further analysis or publication. Their robust design and advanced features make them reliable tools for routine laboratory operations, enhancing both productivity and research accuracy.
Recommendations
To maximize the use and longevity of the Gel Documentation Systems, it is recommended to maintain regular calibration and cleaning schedules for the camera and lens. If possible, follow the manufacturer’s guidelines for optimal performance conditions, including temperature and humidity. Proper training for personnel using the systems ensures not only efficient use but also reduces the risk of damage or misuse. For any questions or advanced troubleshooting needs, relying on Kalstein’s customer service for support is advisable.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we give life to science; it’s time to become part of our community. https://kalstein.net/en/product/gel-documentation-system-yr06063-yr06064/.