Total Organic Carbon Analyzer YR04950: An Essential Tool for Modern Laboratories

The Total Organic Carbon Analyzer YR04950 is an advanced tool designed to accurately and reliably measure the total organic carbon content in liquid samples. This device is equipped with an NDIR (Non-Dispersive Infrared) detector, ensuring high sensitivity and precision in detecting various parameters, including TC (Total Carbon), TIC (Total Inorganic Carbon), TOC (Total Organic Carbon), and NPOC (Non-Purgeable Organic Carbon).

The YR04950 employs a UV wet chemical oxidation method, an effective process that allows the complete oxidation of organic matter present in samples. Its operation is controlled by PC software, providing an intuitive user interface and facilitating data analysis. This analyzer is ideal for applications requiring water quality assessment, such as in water treatment plants, environmental research laboratories, and the beverage industry.

The measurement range of the YR04950 spans from 0 to 10,000 mg/l (ppm), with a detection limit of 5 μg/l (ppb), making it suitable for both low and high concentration samples. Additionally, it offers a repeatability of 3%, ensuring consistent results. With a maximum salinity tolerance of 85 g/l and power supply options of AC220V, 50Hz or AC110V, 60HZ, 200W, this analyzer is versatile and adaptable to different laboratory environments.

Market Price

The price of the Total Organic Carbon Analyzer YR04950 can vary depending on the supplier and additional features required. Generally, this type of analyzer is found in a price range between $10,000 and $15,000, which includes initial calibration costs and control software. This price range makes it competitive compared to other models available on the market, offering excellent value for laboratories seeking precision and reliability in their total organic carbon measurements.

Frequently Asked Questions

What types of samples can be analyzed with the YR04950?

The YR04950 is designed to analyze liquid samples, including drinking water, wastewater, and industrial samples, allowing for a detailed evaluation of organic carbon content.

How is the analyzer controlled?

The analyzer is controlled via PC software, which offers an easy-to-use interface for parameter configuration, analysis execution, and data interpretation.

What is the detection limit of the YR04950?

The YR04950 has a detection limit of 5 μg/l (ppb), enabling precise detection of low levels of organic carbon in liquid samples.

Advantages and Disadvantages

Advantages:

  • High Precision: The NDIR detector and UV wet chemical oxidation method ensure accurate and reliable measurements.

  • Versatility: Capable of measuring a wide range of carbon concentrations in various liquid samples.

  • Intuitive Interface: Controlled by PC software, facilitating use and result interpretation.

  • High Repeatability: 3% repeatability, ensuring consistency in results.

Disadvantages:

  • Initial Cost: The price may be high for small laboratories with limited budgets.

  • Maintenance: Requires regular maintenance and calibrations to ensure continuous accuracy.

Field Usage

In practice, the Total Organic Carbon Analyzer YR04950 is widely used in monitoring water quality in wastewater and drinking water treatment plants. Its ability to detect low levels of organic carbon makes it ideal for meeting strict environmental regulations. It is also a valuable tool in environmental research laboratories, where precise evaluation of organic load in various water bodies is required.

Recommendations

To maximize the lifespan and performance of the YR04950, it is recommended to follow a regular maintenance program that includes cleaning key components and periodic calibration of the detector. Additionally, it is crucial to ensure that the analyzer is used within the allowed ambient temperature and humidity specifications to avoid damage and maintain optimal operation.

For more details on the Total Organic Carbon Analyzer YR04950 and to receive a personalized quote, we invite you to visit our Kalstein Plus platform, where you can generate an automatic quote quickly and easily. Don’t miss the opportunity to enhance the precision and efficiency of your total organic carbon analyses with this high-quality equipment.

With its combination of functionality, efficiency, and robust design, the YR04950 is a smart investment for any modern laboratory. Request your quote today and discover how this analyzer can transform your total organic carbon analysis processes.

Technical Specifications

Specification

Details

Model

YR04950

Detector

NDIR

Parameters

TC, TIC, TOC, NPOC

Method

UV wet chemical oxidation

Operating Mode

Controlled by PC software

Application

Liquid sample

Gas Requirement

Nitrogen ≥99.995%

Measurement Range

0-10,000 mg/l (ppm)

Detection Limit

5 μg/l (ppb)

Repeatability

3%

Maximum Salinity

85 g/l

Power Supply

AC220V, 50Hz or AC110V, 60Hz, 200W

Size

430 x 455 x 440 mm

In summary, the Total Organic Carbon Analyzer YR04950 is a high-precision and versatile tool, ideal for laboratories requiring detailed analyses of liquid samples. With its robust design and ability to handle a wide range of carbon concentrations, this analyzer offers a reliable and efficient solution for various laboratory applications. Request your quote through Kalstein Plus and discover how the YR04950 can improve the quality and efficiency of your total organic carbon analyses.

If you want to know the catalog of high-end products that we have for you at KALSTEIN visit us https://kalstein.net/en/product/total-organic-carbon-analyzer-yr04950/  we also assure you that through our online purchase channels that are very easy and viable you will find the best PRICES in the market, reminding them that we are a MANUFACTURING Company of High-Level Laboratory Equipment for SALE. https://kalstein.net/en/