The BioPhotometer YR06033 is an essential tool for laboratories seeking precision and efficiency in molecular analysis. This device combines advanced technology with a compact design, making it a versatile and high-quality choice for any laboratory setting. Equipped with a xenon lamp as its light source and a CCD detector with 2048 pixels, the BioPhotometer YR06033 offers a spectral resolution of 0.3 nm, ensuring precise and reliable results across a wide wavelength range, from 190 to 1100 nm.
In addition, it features several outstanding characteristics. Among these, a wavelength accuracy of ±1 nm and the ability to handle minimal sample volumes down to 1 µL, which is ideal for analyzing small amounts of DNA (with a detection limit of up to 2 ng/µL). Weighing just 3 kg, this device is easy to transport, and its compact design (220 x 280 x 220 mm) makes it perfect for laboratories with limited space. Below are its key technical specifications presented in table format:
Technical Specifications
Model | YR06033 |
Generation Specification | |
Light Source | Xenon Lamp |
Detector | CCD (2048 Pixels) |
Wavelength Range | 190-1100nm |
Wavelength Accuracy | ± 1nm |
Spectral Resolution | 0.3nm |
Dimension | 220*280*220 mm |
Weight | 3kg |
Power Supply | 100-240V, 50-60Hz |
Power Consumption | 80-100W |
Nano Volume Specification | |
Absorbance Precision | 1%@100ng/µI |
Absorbance Range | 0-200Abs (10nm equivalent) |
Detection Limit | 2ng/µI (dsDNA) |
Max. Concentration | 15000ng/µI (dsDNA) |
Measurement Time | 5s |
Min. Sample Volume | 1µI |
Path Length | 0.01-1.2mm (auto-ranging) |
Cuvette Specification | |
Beam Height | 8.5mm |
Absorbance Range | 0.002-2.0 Abs |
Measurement Time | 3s |
Path Length | 10mm |
Market Price
The BioPhotometer YR06033 is competitively priced in the market, with a range between $3,000 and $5,000 USD depending on distributors and additional options. Compared to other devices with similar features, the YR06033 stands out for its balance between cost and functionality, making it an affordable option for small and medium-sized laboratories that seek high-quality results without incurring significant costs.
Frequently Asked Questions
What is the detection limit of the BioPhotometer YR06033?
The detection limit for double-stranded DNA samples is 2 ng/µL, allowing for highly precise analysis of small sample amounts.
What types of samples can it measure?
This photometer is designed to measure nucleic acids, proteins, and other biomolecules in small-volume samples, making it a versatile tool for routine molecular biology analysis.
How long does a measurement take?
The standard measurement time is just 5 seconds, allowing for fast and efficient analysis.
Does the device include cuvettes?
The device is compatible with 10 mm cuvettes for traditional analysis, and it can also perform measurements in nanometric volumes without needing a cuvette.
What type of light source does it use?
The BioPhotometer YR06033 uses a xenon lamp, providing longer lifespan and greater stability in measurements.
What is included with the device?
The device comes with all necessary accessories for immediate operation, including analysis software and a detailed user manual.
Advantages and Disadvantages
Pros |
Cons |
High precision in measurements with small volumes |
Higher price compared to basic options |
Xenon lamp ensures stability and durability |
Periodic maintenance of the lamp is required |
Versatile system for both cuvettes and nano volumes |
Not suitable for users who do not need high precision |
Compact and lightweight design, easy to transport |
Lower sample capacity compared to other models |
Intuitive interface for easy operation |
Does not include auto-calibration function |
Quick measurement time (5 seconds) |
|
High-resolution CCD detector (2048 pixels) |
|
Wide wavelength range (190-1100 nm) |
Field Use
In molecular biology, the BioPhotometer YR06033 is a key tool for the quantification of DNA and RNA, as well as for assessing sample purity. Its ability to work with extremely small sample volumes (as little as 1 µL) makes it ideal for laboratories handling precious or scarce samples. Additionally, its portability and compact size allow it to be used in both centralized lab environments and mobile workstations or spaces with limited room.
In clinical analysis laboratories, the YR06033 is used for rapid protein measurements and other biomolecules. Its simple interface and short measurement times make workflows more efficient, allowing laboratories to process more samples in less time without compromising result quality.
Recommendations
To ensure maximum performance of the BioPhotometer YR06033, it is recommended to follow a preventive maintenance program, particularly regarding the xenon lamp, which may be affected by intensive use. Moreover, the device should be operated in a controlled environment, with appropriate temperature and humidity conditions, to avoid interference in measurements.
It is also important to take full advantage of the included software’s capabilities to store and analyze data efficiently, allowing users to improve their analytical processes and obtain more precise and reproducible results.
If you are looking for a device that combines advanced technology with an efficient design, the BioPhotometer YR06033 is the right choice. Kalstein offers the Kalstein Plus platform, where you can quickly and easily generate an automatic quote tailored to your needs.
If you’re searching for a fusion of innovation and quality, you’ve come to the right place. At https://kalstein.net/en/product/biophotometer-micro-spectrophotometer-yr06033/, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a high level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most competitive prices. Don’t hesitate—let’s bring science to life together and become part of our community. https://kalstein.net/en/