Product Description
The Benchtop Spectrophotometer YR05478 is at the forefront of color analysis technology, facilitating precise measurement for laboratory use. Engineered to cater to industries such as paints, inks, textiles, and printing, this spectrophotometer boasts a robust optical geometry featuring both reflectance and transmittance capabilities. It adheres to international standards, including CIE No.15 and ISO7724/1, ensuring unparalleled accuracy and reliability in color analysis and quality control.
A focal point of the YR05478 is its versatile spectrophotometric mode, utilizing a concave grating to deliver optimal spectral data. Equipped with a 256 image element double array CMOS image sensor, it confidently covers a wavelength range of 360-780 nm, with a tight interval and semibandwidth of 10 nm. The integrating sphere, measuring Φ154mm, efficiently captures light for both reflective and transmissive measurements, ensuring comprehensive data fidelity.
Technical Specifications
Model | YR05478 |
Optical Geometry | Reflect: di:8°, de:8°; SCI/SCE; UV included/excluded; Conforms to CIE No.15, GB/T standards |
Application | Color analysis and transmission in paints, inks, textiles, printing, etc. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm |
Transmissive : Φ30mm/Φ25mm | |
Remarks: Automatic identification of switch caliber; Custom configurations available | |
Specular Component | Reflectance: SCI⪰ Transmittance: SCI&SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc, ΔE*00, DINΔE99, ΔE(Hunter) |
Other Colorimetric Index | WI, YI, MI, Staining Fastness, Color Fastness, etc. |
Glossiness, Gardner Index, Pt-Co Index, 555 Index | |
Haze(ASTM D1003) | |
Observer Angle | 2°/10° |
Illuminant | D65, A, C, D50, D55, D75, F1-F12 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, PASS/FAIL Result |
Measuring Time | Approx. 2.4s |
Repeatability | Spectral reflectance: within 0.06% |
Chromaticity value: Standard deviation within ΔE*ab 0.01 | |
Spectral Transmittance: within 0.06% | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
Dimension | L*W*H=370x300x200mm |
Weight | Approx. 9.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, over 3 million measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Print serial port |
Data Storage | Standard 1000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, CD Disk, USB cable, Calibration Boards |
Optional Accessory | Micro-printer, Transmissive Test Component |
Notes: Specifications may change without notice. YS6003 software for data management. |
Market Price
The Benchtop Spectrophotometer YR05478 typically falls within a competitive price range for high-caliber instruments of its kind. Although prices may vary based on region, distributor, and accessory packages, potential buyers can expect a starting point around $5,000 to $8,000. It’s recommended to request a precise quote or take advantage of Kalstein’s online price management tools for accurate and up-to-date pricing.
To ensure you receive the best value, it is wise to consider the long-term savings such an advanced piece of equipment can provide through efficient and precise measurements, minimized errors, and enhanced laboratory productivity.
Frequently Asked Questions
What industries benefit most from the YR05478 spectrophotometer?
This spectrophotometer is excellent for industries requiring stringent color accuracy, including paints, textiles, printing, and coatings. It’s designed to support quality control and enhance product standards.
How does the measurement process work?
Measurements are conducted via its integrating sphere and CMOS Image Sensor to analyze reflectance and transmittance effectively. The device supports switching between specular included and excluded options for enhanced versatility.
Advantages and Disadvantages
Advantages: The YR05478 offers precise and reliable color measurement capable of supporting extensive quality control frameworks. Its wide range of applicable color spaces and measurements makes it an invaluable tool for laboratories seeking versatility and accuracy.
Automatic calibration and intelligent aperture recognition streamline operations, enhancing user experience. Additionally, the substantial lifespan of the light source (over 3 million measurements) equates to outstanding durability and cost efficiency.
Disadvantages: While advanced, the YR05478 requires a significant initial investment, which may be a consideration for smaller operations. Furthermore, users may require specific training to fully leverage its capabilities, potentially extending the time to full operational integration.
Use in the Field
In practical applications, the YR05478 has proven its efficacy in both R&D settings and production lines. Its ability to accurately capture color data ensures superior product consistency and aids in meeting stringent regulatory standards. Industries like automotive, where color matching is critical, have significantly benefited from its precise analytical capacity.
In textiles, for example, the instrument not only ensures color fidelity between batches but also assists in diagnosing color fastness problems. Its rapid processing capabilities, delivering results in just a few seconds, enable real-time quality assurance processes.
Recommendations
For users seeking to maximize the b YR05478, regular calibration using the provided standard calibration board is recommended. This practice maintains measurement accuracy and prolongs device life.
Explore optional accessories like the micro-printer for easy data documentation, a feature especially useful in environments requiring intensive report generation. For continuous optimization, engage with Kalstein’s support for any operational queries or further training needs.
If you are looking for a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, guaranteeing the friendliest prices. Do not hesitate any longer, we bring science to life, it is time to become part of our community. https://kalstein.net/en/product/benchtop-spectrophotometer-yr05478/.