Advanced Table-Top Autoclaves: Cutting-Edge Features and Specifications

Product Description

The Class N Table-Top Autoclave series, ranging from models YR03391 to YR03394, exemplifies technological sophistication in sterilization. These autoclaves are crafted meticulously for laboratory environments, ensuring a compact yet powerful solution. The chamber dimensions vary from Ø170×320 mm to Ø247×450 mm, allowing for different capacity needs, with chamber volumes spanning 8 L to 23 L. This diversity makes them adaptable to a wide range of laboratory sizes and types.

Each unit supports multiple trays, optimizing space for diverse sterilization needs. Models YR03391 and YR03392 can accommodate 2 to 3 trays, while YR03393 and YR03394 can hold up to 4 trays, meeting higher capacity requirements efficiently. These autoclaves operate on a voltage system of 220/110V, working effectively within a frequency of 50/60Hz, ensuring global compatibility.

Order Code YR03391 YR03392 YR03393 YR03394
Chamber Dimension Ø170×320 mm Ø200×360 mm Ø247×350 mm Ø247×450 mm
Chamber Volume 8 L 12 L 18 L 23 L
Number of Trays 2/ Max. 3 2/ Max. 3 3/ Max. 4 3/ Max. 4
Size of Trays 130×265 mm 156×295 mm 192×285 mm 192×380 mm
Voltage, Freq. 220/110V, 50/60Hz 220/110V, 50/60Hz 220/110v, 50/60Hz 220/110v, 50/60Hz
POWER 1900 w 1900 w 1900 w 2100 w
Overall Dimension (WxHxD) 420x370x525 mm 420x370x595 mm 490x455x600 mm 490x455x690 mm
Weight 35 kgs 38 kgs 45 kgs 50 kgs

Market Price

The market price for table-top autoclaves like the YR03391 to YR03394 can vary widely based on features, capacity, and brand reputation. Typically, high-quality units range from $2,000 to $5,000. While these initial costs may seem substantial, investing in a reliable sterilization unit ultimately translates to long-term savings by enhancing efficiency and reliability in critical laboratory processes. For a specific quote, users can easily generate an automatic quotation via the Kalstein Plus platform, ensuring they receive competitive pricing and custom solutions tailored to their needs.

Frequently Asked Questions

What type of maintenance do these autoclaves require?

Regular maintenance for these autoclaves includes routine cleaning and inspection of the chamber and trays, checking seals and gaskets, and following the manufacturer’s recommendations for servicing.

Are these autoclaves suitable for all microorganisms?

Yes, the Class N Autoclaves are designed to sterilize a broad spectrum of microorganisms, making them versatile for various laboratory contexts.

Can these autoclaves be used for liquids?

While they are primarily designed for dry materials, consult the manufacturer’s guidelines regarding their use for sterilizing liquids, as special configurations may be needed.

Advantages and Disadvantages

Advantages:

  • Versatile tray capacity, allowing for maximum use of space.
  • Global voltage and frequency compatibility, making them suitable for international laboratories.
  • High power efficiency ensures rapid and thorough sterilization.

Disadvantages:

  • Initial cost may be high, which could be a barrier for smaller laboratories.
  • Regular maintenance and proper handling are essential to avoid reduced performance over time.

Product Use in the Field

These table-top autoclaves are ideal for laboratories requiring regular and reliable sterilization of instruments and materials. In research and medical labs, they operate efficiently to ensure the sterility of tools, reducing contamination risks drastically. Their compact design is perfect for labs with limited space, without sacrificing power or capacity. For maximum efficiency, users should always follow operational guidelines precisely.

Using these autoclaves according to best practices, including proper loading techniques and cycle selections, maximizes their sterilization capabilities. Whether in educational settings, research institutions, or hospital laboratories, their user-friendly interface ensures anyone can operate them confidently after minimal training.

Recommendations

To ensure the longevity and optimal performance of your autoclave, follow these recommendations:

  • Conduct regular maintenance checks, focusing on the seals and heating elements.
  • Use distilled water to prevent mineral buildup that can impair function.
  • Regularly calibrate the unit according to manufacturer specifications to maintain accuracy.
  • Keep a record of the loading and usage patterns to identify any potential issues proactively.

If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/class-n-table-top-autoclave-yr03391-yr03394/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]