Product Description
The YR02936 model of the laboratory hot plate magnetic stirrer stands out for its precision and versatility, essential for any modern laboratory. With a spacious top plate dimension of 280 × 280 mm, it accommodates various flask sizes, ranging from 50 to 15,000 ml, making it ideal for diverse experimental needs. The heating temperature range is robust, stretching from ambient temperature up to 400 degrees Celsius, which covers a wide spectrum of scientific applications.
One of the standout features of this model is its LED temperature control display that leverages PID control technology to maintain optimal temperature stability. The top plate is available in black or white ceramic, known for its durability and ease of cleaning, catering to different aesthetic and practical preferences. The temperature accuracy stands at an impressive ±5 degrees, ensuring reliable results for critical experiments.
| Model | YR02936 |
| Top Plate Dimension (mm) | 280 × 280 |
| Heating Temperature Range (°C) | Ambient to 400 degrees |
| Temperature Control | PID control LED display when the machine works. |
| Temperature Range | Ambient to 400 |
| Top Material | black ceramic or white ceramic |
| Temperature Display | ±5 degrees |
| Permissible Ambient Temperature | Ambient temperature at 40 degrees |
| Voltage | 110 V – 240 V |
| Power(w) | 450 W |
| Motor Power | 16W, DC20V |
| Temperature Accuracy | ±5 degrees |
| Stirring Flask Capacity (ml) | 50 – 15,000 |
| Overall Dimensions (mm) ( L × W × H ) | 500 x 420 x 270 |
| Packing Dimension (mm) | 550 x 450 x 290 |
| Shipping Weight (kg) | 9.5 Kg |
| Shell material | Superfine Metal |
Market Price
The laboratory hot plate magnetic stirrer YR02936 typically falls within a competitive price range in the market, reflecting its advanced technological features and build quality. Prices can vary depending on suppliers and any additional accessories or warranties provided. Generally, purchasers can expect to invest between $300 and $600 for a unit of this caliber. It’s advisable for buyers to compare prices from various suppliers and consider bulk purchasing options or promotions to secure the best deals.
Frequently Asked Questions
What is the maximum temperature the hot plate can reach?
The YR02936 model can heat up to 400 degrees Celsius, making it suitable for a range of laboratory applications.
What types of materials are available for the top plate?
The hot plate comes with either black or white ceramic top plates, which are durable and easy to clean.
How accurate is the temperature control?
The unit offers temperature accuracy within ±5 degrees, ensuring precise control over experiments.
Advantages and Disadvantages
One of the main advantages of the YR02936 hot plate magnetic stirrer is its high level of temperature control precision, courtesy of the PID control system. Its wide temperature range and large capacity also cater to numerous applications, making it a versatile lab tool. The option to choose between black or white ceramic for the top plate could be appealing both functionally and aesthetically.
Potential drawbacks might include the dependency on a stable power supply, given its broad voltage operational range (110 V – 240 V), which could be a consideration in areas with fluctuating electrical infrastructure. Additionally, with a power rating of 450W, users will need to ensure sufficient power delivery in their laboratory setting.
Product Usage in the Field
In practical scenarios, the YR02936 is utilized across a spectrum of scientific experiments that require simultaneous heating and stirring. Its application is prevalent in chemistry labs for dissolving solids into solutions or maintaining suspensions. Furthermore, the precision of the PID control ensures sensitive reactions are maintained at consistent temperatures, crucial for reproducible results.
Researchers can benefit from the stirrer’s capacity range, which allows it to handle both small and large volumes, accommodating varying levels of experimentation from small-scale tests to larger batches in industrial applications.
Recommendations
To maximize the efficiency and lifespan of the YR02936, regular maintenance checks are recommended, especially focusing on the cleanliness of the ceramic plate to prevent residue build-up. Users should also periodically verify the calibration of the digital display to ensure precise temperature measurements. Implementing a routine check for the power supply connections can also prevent electrical faults and ensure the equipment consistently operates at its optimal performance.
For those interested in exploring these capabilities further, generating a quotation through Kalstein Plus can offer insights into the best purchasing options. Explore your laboratory solutions with Kalstein and transform your experimental outcomes today.
If you are seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate anymore, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/laboratory-hot-plate-magnetic-stirrer-yr02936/.