Product Description
The Tumor Markers Test Kit series, models YRA299 to YRA316, offers a comprehensive solution for detecting specific tumor markers crucial in cancer diagnosis and monitoring. With each model targeting different parameters such as AFP, CEA, FER, CA125, and more, these kits are designed to provide accurate results through Chemiluminescent Immunoassay (CLIA) technology. The utilization of Alkaline Phosphatase (AP) as a platform ensures enhanced sensitivity and efficiency, catering to the needs of modern laboratories.
These kits are packaged conveniently in specifications of 50T/BOX, 100T/BOX, and 24T/BOX, supporting flexibility in laboratory workloads. Designed to be stored at temperatures ranging from 2-8°C, these kits come with CE, ISO13485, and FSC certifications, assuring compliance with international standards. The calibration options include 2 or 6 points, allowing for precision tuning based on laboratory requirements.
| Model | YRA299 | YRA300 | YRA301 | YRA302 | YRA303 | YRA304 | YRA305 | YRA306 | YRA307 |
| Tested Parameter | AFP | CEA | FER | CA125 | CA15-3 | CA19-9 | t-PSA | f-PSA | SCC |
| Analysis Mode | CLIA | ||||||||
| Package Specification | 50T/BOX, 100T/BOX, 24T/BOX | ||||||||
| Platform | AP(Alkaline Phosphatase) | ||||||||
| Storage | 2-8°C | ||||||||
| Calibration | 2/6 Points | ||||||||
| Certification | CE, ISO13485, FSC | ||||||||
| Model | YRA308 | YRA309 | YRA310 | YRA311 | YRA312 | YRA313 | YRA314 | YRA315 | YRA316 |
| Tested Parameter | NSE | CA50 | PGI | PGII | CYFRA 21-1 | CA72-4 | CA242 | pro-GRP | HE4 |
| Analysis Mode | CLIA | ||||||||
| Package Specification | 50T/BOX, 100T/BOX, 24T/BOX | ||||||||
| Platform | AP(Alkaline Phosphatase) | ||||||||
| Storage | 2-8°C | ||||||||
| Calibration | 2/6 Points | ||||||||
| Certification | CE, ISO13485, FSC | ||||||||
Market Price
In the competitive landscape of tumor markers test kits, pricing varies based on features and specifications. On average, the Tumor Markers Test Kit series ranges from $200 to $500 per box, depending on the tested parameter and quantity per box. Kalstein provides competitive pricing and the option to generate quotations automatically through Kalstein Plus, ensuring a seamless purchasing experience.
Frequently Asked Questions
What is the primary use of the Tumor Markers Test Kit?
The primary use of the kit is for the quantitative detection of various tumor markers in human samples, aiding in cancer diagnosis and monitoring.
What storage conditions are required?
The kits should be stored at a temperature between 2-8°C to ensure their efficacy and longevity.
Does the kit include calibration options?
Yes, the kit includes calibration options with 2/6 points, accommodating diverse laboratory needs.
Advantages and Disadvantages
Advantages: The Tumor Markers Test Kit series offers high sensitivity and specificity thanks to the CLIA technology and the use of AP as a platform. The wide range of parameters covered allows for comprehensive cancer marker testing, and its compliance with CE and ISO13485 certifications ensures product reliability.
Disadvantages: The dependency on specific storage conditions (2-8°C) may pose challenges in some environments. Additionally, the need for proper calibration might require additional resources in less equipped labs.
Product Usage in the Field
These kits are primarily used in clinical laboratories and research centers for the detection of tumor markers in human samples. Utilizing CLIA technology enables laboratories to efficiently process samples with high throughput, ensuring timely results critical for patient management. Their user-friendly design and comprehensive instructions make them suitable for integration into existing diagnostic workflows.
The diverse range of parameters covered by the YRA series, including markers like CA125 and PSA, provides flexibility and efficacy in diagnosing different types of cancers, thus supporting clinical teams in making informed decisions.
Recommendations
For optimal results, it is recommended to strictly adhere to the storage and handling guidelines outlined for the Tumor Markers Test Kit series. Regular calibration in accordance with laboratory standards should be conducted to maintain accuracy and reliability. Utilizing the Kalstein Plus platform not only streamlines the purchasing process but also ensures access to the latest kits and updates seamlessly.
To fully leverage the capabilities of these kits, laboratory technicians should undergo training on CLIA technology and marker-specific testing protocols, ensuring proficient usage and interpretation of the results.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/tumor-markers-test-kit-yra299-yra316/.