Advanced Laminar Flow Cabinets: Technical Insights and Practical Benefits

Product Description

The Laminar Flow Cabinet models YR06430 and YR06430-1 are designed to provide a controlled, contamination-free environment that is ideal for laboratory work. These cabinets achieve a Class 100 cleanliness grade according to US Federal Standard 209E, ensuring a sterile atmosphere through the use of efficient high-efficiency particulate air (HEPA) filters. The average wind speed ranges from 0.25 to 0.45 m/s, ensuring consistent airflow without disturbing sensitive procedures.

Noise levels are kept to a maximum of 62dB (A), providing a quiet working environment, essential for prolonged use. Both models come equipped with advanced UV and fluorescent lighting solutions, offering an illumination level of at least 300LX, ensuring clear visibility for intricate tasks.

Model YR06430 YR06430-1
Cleanliness grade Class 100 (US Federal 209E)
Number of colonies ≤0.5pcs/dish-hour ($90mm culture dish)
The average wind speed 0.25~0.45m/s
Noise ≤62dB (A)
Power supply AC single phase 220V/50Hz
Vibration half peak ≤0.5µM (x, y, z direction)
Illumination ≥300LX
Max. Power consumption 100W 500W
Dimension of working area (W*D*H) (mm) 700*550*580 1150*550*580mm
Overall dimension (W*D*H) (mm) 860*590*1600 1310*590*1600mm
Specification and quantity of high efficiency filter 685*455*50*1 1135*455*50*1
Specification and quantity of fluorescent lamp/UV lamp 12W*1/20W*1 12W/30W*1

Market Price

The price of laminar flow cabinets, such as models YR06430 and YR06430-1, can vary significantly based on features and supplier. On average, the cost can range from approximately $1,500 to $5,000. Higher-end models offering additional features and advanced filtration systems might be priced at the upper end of this spectrum. It is crucial to ensure a balance between cost and quality to meet specific laboratory requirements efficiently.

Frequently Asked Questions

What is the primary use of a laminar flow cabinet?

Laminar flow cabinets are primarily used to create a clean, sterile environment for laboratory tasks requiring contamination control, such as microbiology and tissue culture work.

What maintenance is required for these cabinets?

Regular maintenance includes checking and replacing HEPA filters, cleaning surfaces, and ensuring proper airflow and lighting conditions. Adhering to manufacturer guidelines will optimize performance and longevity.

Can these cabinets be used for handling hazardous substances?

No, laminar flow cabinets are not designed for hazardous substances or chemicals. They are intended for protection of samples from particulate contamination, not for operator safety with regard to fumes or biohazards.

Advantages and Disadvantages

The YR06430 and YR06430-1 offer numerous advantages, including high cleanliness standards, noise reduction, and strong illumination, making them indispensable for precision scientific work. The user-friendly design allows for ease of operation and minimal disturbance to sensitive processes.

On the downside, these cabinets might not be suitable for low-budget laboratories due to their cost. Moreover, they do not provide protection for the user from hazardous materials and require consistent maintenance to sustain optimal functionality.

Product Use in the Field

Laminar flow cabinets are extensively used in fields like pharmacology, research and development, and microbiology, where the integrity of samples is critical. By maintaining a contamination-free environment, these cabinets support crucial experiments and research activities, ensuring accurate and reliable results.

Laboratories working with cultures, preparing sterile solutions, or assembling highly sensitive electronic components often utilize these cabinets to ensure micro-level cleanliness. Their design supports erecting a barrier against potential contaminants, enhancing the overall quality of laboratory outputs.

Recommendations

To maximize the benefits of your laminar flow cabinet, it is recommended that users conduct regular training on appropriate usage practices, including the correct set-up and shut-down procedures. Routine maintenance checks are pivotal in preventing unexpected downtime and ensuring the cabinet remains in top condition.

Position your cabinet in a draft-free area to prevent interference with the laminar airflow. Correct placement and setup can extend the life of the filters and secure a contamination-free workspace. For further assistance, consider reaching out to suppliers or manufacturers for any specific troubleshooting needs.

If you’re seeking a blend of innovation and quality, you’ve come to the right place. At Kalstein, we invite you to explore our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence that meets the highest standards. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer; we bring science to life, and it’s time for you to become part of our community. https://kalstein.net/en/product/laminar-flow-cabinet-yr06430-yr06430-1/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]