Innovative COD Analyzer YR06295: A Leap in Spectrophotometry

Product Description

The COD Analyzer YR06295 stands as a pinnacle of modern laboratory equipment, designed to deliver unparalleled accuracy and efficiency in spectrophotometry. This advanced device employs a sophisticated measurement method known as fast digestion spectrophotometry, which allows for quick and reliable results across a wide measuring range of 10-10000 mg/L.

One of the standout features of the YR06295 is its impressive accuracy of less than 5%, coupled with a resolution of 0.01. The imported silicon photodiode serves as a robust light source, ensuring consistent performance and precise readings. Navigating the results is made hassle-free with a high-resolution 7-inch touch screen display with a resolution of 1024 * 600, providing a user-friendly interface for easy operation.

Data management is efficiently handled through a USB output, facilitating seamless data transfer. The device is versatile in its power requirements, compatible with AC 220V/50Hz or AC 110V/60Hz, making it adaptable to various laboratory settings. The COD Analyzer YR06295 operates optimally within an ambient temperature range of 5-40°C and can tolerate relative humidity levels of up to 85%, provided there’s no condensation.

Model YR06295
Measurement Method Fast digestion spectrophotometry
Measuring Range 10-10000mg/L
Accuracy <5%
Resolution 0.01
Light Source Imported Silicon Photodiode
Display 7-inch high-resolution 1024 * 600 touch screen
Output USB (for data transfer)
Power AC 220V/50Hz or AC 110V/60Hz
Ambient Temperature (5-40) °C
Ambient Humidity Relative humidity ≤ 85% (No condensation)

Market Price

The COD Analyzer YR06295 is competitively priced within the market. Typically, such advanced laboratory equipment ranges from approximately $5,000 to $10,000, depending on the supplier and additional features. However, at Kalstein, we offer competitive pricing to ensure that our high-quality products are accessible to laboratories around the world.

Understanding the importance of cost-efficiency in laboratory settings, we provide a platform where you can generate a quote automatically through Kalstein Plus, ensuring transparency and facilitating your purchasing decision.

Frequently Asked Questions

What is the main function of the COD Analyzer YR06295?

The COD Analyzer YR06295 is primarily used to measure the chemical oxygen demand in water and wastewater, providing quick and accurate results essential for environmental monitoring and treatment processes.

How is data retrieved from the device?

Data can be easily transferred using the USB output, which allows for efficient data management and storage.

Is the device user-friendly?

Yes, the device features a 7-inch high-resolution touch screen that makes navigation and operation highly intuitive for users.

Advantages and Disadvantages

Advantages: The YR06295 offers high accuracy and precision, a user-friendly interface, and a wide measuring range suitable for various applications. Its robust design ensures consistent results even under different environmental conditions.

Disadvantages: One potential downside could be the initial investment cost, although this is offset by the equipment’s reliability and long-term value. Additionally, the device requires careful handling and regular maintenance to ensure its longevity and optimal performance.

Using the Product in the Field

The COD Analyzer YR06295 is extensively used in environmental science, quality control in water treatment facilities, and industrial processes where monitoring of water pollutants is crucial. Its fast digestion spectrophotometry method allows for quick readings, making it invaluable in fieldwork where time is of the essence.

In practical scenarios, the device is set up in laboratory environments or on-site, where it aids technicians in acquiring precise data quickly. The robust design and tolerance to varying environmental conditions make it suitable for diverse applications and harsh environments.

Recommendations

To maximize the performance and longevity of the COD Analyzer YR06295, it is advisable to follow certain guidelines. Regular calibration and maintenance are recommended to ensure continued accuracy and performance. Ensure the device operates within the specified ambient temperature and humidity ranges to prevent any potential damage or inaccuracies.

Proper training for personnel on how to effectively utilize the device can also contribute to maximizing its benefits. Consider exploring Kalstein Plus for your purchasing needs, as it offers an efficient way to manage quotes and fulfill your laboratory equipment requirements.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life; it’s time to be a part of our community. https://kalstein.net/en/product/cod-analyzer-yr06295/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]