The Electrosurgical Generator YR02147 stands at the forefront of surgical technology, offering a diverse range of functions designed to cater to modern surgical needs. With its cutting-edge design, this generator operates effectively in both monopolar and bipolar modes, providing maximum power tailored to precise load requirements. Its standout feature, the **Monopolar Cut** at 60W/500Ω in pure cut mode, ensures exact incision capabilities, enhancing procedural accuracy.
Furthermore, the generator offers **Blend 1** at 50W/500Ω, delivering adaptability and control tailored to individual surgical demands. The **Monopolar Coagulation** feature works at 50W/500Ω, essential for effective tissue coagulation. In **Bipolar Modes**, both the cut and coag functionalities function at a power of 40W/100Ω, ensuring a broadened range of surgical applications while maintaining optimal safety standards. The device’s electrical requirements are meticulously specified, with a maximum input current of 1400VA and finely measured monopolar and bipolar frequencies, 4.0MHz ±2% and 1.84MHz ±2%, respectively.
| Model | YR02147 | |
| Working Mode | Max Power / Rated Load | |
| Monopolar Cut | Pure cut | 60W / 500Ω |
| Blend 1 | 50W / 500Ω | |
| Monopolar Coag | Standard Coag | 50W /500Ω |
| Bipolar Cut | Bipolar Cut | 40W / 100Ω |
| Bipolar Coag | Bipolar Coag | 40W / 100Ω |
| Electrical requirement | Monopolar Measuring Frequency | 4.0MHZ ±2% |
| Bipolar Measuring Frequency | 1.84MHZ ±2% | |
| Max Input Currency | 1400VA | |
| Environmental Conditions for Use | Condition | Range |
| Temperature | 50°C to 40°C | |
| Relative humidity | ≤ 95% non-condensing | |
| Pressure | 700 hPa to 1060 hPa | |
Market Price
The Electrosurgical Generator YR02147, with its sophisticated features and reliable performance, is priced competitively in the market. The average market price for this type of generator ranges from $3900 to $4700. This reflects its value considering the advanced functionalities and robust design it brings to surgical operations. Obtaining this device not only provides cutting-edge technology but also ensures long-term investment in surgical efficiency and precision.
Frequently Asked Questions
What are the main features of the Electrosurgical Generator YR02147?
The main features include its dual working modes (monopolar and bipolar), different cutting and coagulation settings, and precise electrical specifications that ensure versatility and efficiency in surgical environments.
Is the Electrosurgical Generator YR02147 suitable for all types of surgeries?
Yes, its design caters to a wide range of surgeries, ensuring precision cuts and effective coagulation, making it adaptable to various surgical needs.
How do I maintain the Electrosurgical Generator to ensure optimal performance?
Regular cleaning, proper storage, and adherence to the specified voltage and current requirements are critical to maintaining optimal performance and longevity.
Advantages and Disadvantages
The Electrosurgical Generator YR02147 is accompanied by several advantages like its adaptability to both monopolar and bipolar surgical techniques, precision in cutting and coagulation, and compliance with required electrical specifications. These features ensure that surgeons have all the tools necessary for effective surgical interventions with minimal complications.
However, as with any complex equipment, the potential disadvantages include the need for adequate training to maximize its functionalities and ensure safety. Surgeons and medical staff need to be well-versed with its operations to avoid misuse and potential technical issues.
Use of the Product in the Field
Electrosurgical generators like the YR02147 are commonly used in hospitals and clinical settings worldwide. They facilitate a vast range of surgical procedures, from minor outpatient treatments to extensive surgeries. The ability to switch between monopolar and bipolar modes allows medical professionals to switch seamlessly between procedures tailored to patient-specific needs.
The YR02147, with its reliable performance and precision capabilities, is indispensable in surgical theatres, providing the necessary flexibility and power to handle diverse medical scenarios efficiently and safely.
Recommendations
To ensure the continued reliable operation of the Electrosurgical Generator YR02147, it is recommended that regular maintenance checks are conducted. Users should also be thoroughly trained in its functionality to harness its full potential, while following all safety guidelines to guarantee both patient and operator safety during procedures.
Users should frequently verify that its electrical connections meet the device’s specifications and conduct periodic reviews of its performance data to adjust settings appropriately for different surgical needs.
If you are looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with an unparalleled level of excellence. Our intuitive and efficient online purchasing channels are designed for your convenience, ensuring the most competitive prices. Do not hesitate any longer; we bring science to life, and it’s time to become part of our community. https://kalstein.net/en/product/electrosurgical-generators-yr02147/.